6200 12TH DR SE 2020-10-22
>
Address Records
>
12TH DR SE
>
6200
>
6200 12TH DR SE 2020-10-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2020 8:36:09 AM
Creation date
5/19/2020 8:57:50 AM
Metadata
Fields
Template:
Address Document
Street Name
12TH DR SE
Street Number
6200
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
537
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Prescriptive Path, pct. 2 ENV-PRESCRIPTIVE <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Everett Safe Streets Supportive Housing Date 07/06/2017 <br /> Fenestration Area as%gross above-grade wall area 27.9% Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0% <br /> If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1,then the project must comp!) <br /> via Component Performance and provide ENV-UA and ENV-SHGC forms. <br /> BuildingComponent R-Value Method for U-Factor/F-Factor Method for <br /> Om p Prescriptive Compliance Prescriptive Compliance <br /> Perim.Ins. Full Slab CI <br /> Provide plan/detail#of assembly and description R-Value R-Value F-Factor F-Factor Source10 <br /> 0 <br /> a ami <br /> o <br /> = Slab on Grade Assembly FC1/A5.2 R-10 Appendix A <br /> Ins. Assembly <br /> Provide ID from door schedule and description R-Value U-Factor U-Factor Source" <br /> „rite <br /> o c' <br /> 0 <br /> o rn Door Schedules A8.1 (100,111b, 114b,132) 0.370 Appendix A <br /> o <br /> Solar Heat Gain Coefficient(SHGC) U-Factor for Prescriptive Compliance <br /> Hrolection Orientation <br /> Factor(PF) (N or Assembly Assembly <br /> Provide ID from window schedule and description if applicable12 SEW)13 SHGC14 U-Factor U-Factor Source14 <br /> 106C, 106d, 126b Fiberglass Door Sheet A8.1 n/a SEW 0.30 0.19 Cascadia Windows <br /> A thru G Vinyl Window Sheet A8.3 n/a SEW 0.24 0.17 VPI Windows <br /> Z A thru G Vinyl Window Sheet A8.3 n/a N 0.24 0.17 VPI Windows <br /> c a <br /> 0 <br /> .c <br /> rn - <br /> ASD N/A N 0.53 0.60 C303.1.3 <br /> u- 2 ASA,ASB,ASC,C1 Storefront Sheet A8.1 N/A SEW 0.40 0.60 C303.1.3 <br /> Tz a <br /> ▪ 0 <br /> 2 <br /> • m <br /> o <br /> H <br /> cn <br /> Note 1-Insulation that is continuous except for fasteners may be entered here if the cross-sectional area of metal penetration through otherwise <br /> continuous insulation is less than 0.12%. <br /> Note 2-Alternate prescriptive continuous insulation R-values per Table C402.1.4,Footnote F may be used if the cross sectional area of metal <br /> penetrations exceeds 0.04%but is less than 0.12%.Calculations are required to use these alternate R-values. <br /> Note 3-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. Specify the <br /> table number or calculation page number. <br /> Note 4-Thermal spacer blocking and liner system are required for prescriptive R-Value compliance in metal building roof assemblies. <br /> Note 5-Intermediate framing is required for prescriptive R-Value compliance in wood-framed wall assemblies. <br /> Note 6-Proposed CMU mass walls in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target prescriptive <br /> U-value of 0.104. <br /> Note 7-Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br /> Note 8-Refer to Table C402.1.3,Footnote E for prescriptive R-Value requirement for steel floor joist assemblies. <br /> Note 9 -Prescriptive slab-on-grade insulation shall extend from top of slab to minimum length per an approved method as defined in C402.2.6. <br /> Note 10-Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 11-Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 12-Refer to Equation C4-6 Projection Factor Calculation. <br /> Note 13-N=Oriented within 45 degrees of true north,SEW=All other orientations. <br /> Note 14-Fenestration assembly U-Factor and SHGC shall be the manufacturer's NFRC product rating,which includes the glazing and frame,or <br /> shall be the default value per Section C303.1.3. <br /> Note 15-List all above-grade Group R mass walls and steel frame walls in Group R Walls section. List commercial above grade walls and all other <br /> Group R above grade walls in Opaque Walls-Above Grade. <br /> 33 <br />
The URL can be used to link to this page
Your browser does not support the video tag.