Laserfiche WebLink
r <br /> M=" Client: New West Development Date: 10/24/2018 Page 1 of 2 <br /> iSL��S gn, Project Kennedy Residence Designer Mark McLain <br /> J(,j Address: 3815 Shore Ave.Everett,WA. Job Name: CCaaae New West Devetopmem-Kornedy Residonco <br /> Project#: CC8889 <br /> U18 2.0E Rigidlam LVL 5.250" X 11.875" Level:Level <br /> Hole check, no repair required: <br /> 2 5 6 <br /> 4 <br /> j <br /> Iiii 0 0 0 00 0 0 0 0 • 11 /8" <br /> s <br /> 1 D Fir 2 D.Fir <br /> / 8,8., / t '15 1/4" <br /> / 8'8" / <br /> Member Information Reactions UNPATTERNED lb(Uplift) <br /> Type: Girder Application: Floor Brg Live Dead Snow Wind Const <br /> Plies: 1 Design Method: ASD 1 4290 3646 0 0 0 <br /> Moisture Condition: Dry Building Code: IBC/IRC 2015 2 1531 1417 0 0 0 <br /> Deflection LL: 480 Load Sharing: No <br /> Deflection TL: 240 Deck: Not Checked <br /> Importance: Normal <br /> Temperature: Temp<=100°F <br /> General Load Bearings <br /> Floor Live: 40 PSF Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb. <br /> Dead: 10 PSF 1-D.Fir 5.500" 44% 3646/4290 7937 L D+L <br /> 2-D.Fir 5.500" 16% 1417/1531 2948 L D+L <br /> Analysis Results Hole Analysis Hole number <br /> Analysis Actual Location Allowed Capacity Comb. Case <br /> Moment 4071 ft-lb 42" 23924 ft-lb 0.170(17%)D+L L Holes Location Size Ratio Actual Allowed <br /> Shear H1'8" 1 O 0.157 6732 <br /> Unbraced 4071 ft-lb 4'2" 23633 ft-lb 0.172(17%)D+L L Moment Orr 0.128 3012 ft-lb 23520 ft-lb <br /> Shear 2413 lb 1'4 5/8" 12053 lb 0.200(20%)D+L L <br /> LL Defl inch 0.017(L/5605) 4'2" 0.197(L/480) 0.090(9%) L L Shear H2' 2 1" 0.093 941 10109 <br /> TL Dell inch 0.030(L/3163) 3'4" 0.394(L/240) 0.080(8%) D+L L Moment 6rr <br /> 0.139 3295 ft-lb 23633 ft-lb <br /> Shear H2'8" it 3 1" 0.071 718 10109 <br /> Design Notes Moment 3 0.158 3733 ft-lb 23633 ft-lb <br /> Design Notes Shear H2'11" 4 1" 0.063 635 10109 <br /> 1 Holes in LVL are in accordance with APA Form No.EWS G535,Figure 2. u <br /> 2 Girders are designed to be supported on the bottom edge•. Moment 3 0.163 3852 ft-lb 23633 ft-Ib <br /> 3 Top braced at bearings. " t..1 tt�� Shear H3'2" 5 1" r r 553 10109 <br /> 4 Bottom braced at bearings. ,,, `7 ,, Moment 2" <br /> • 0.167 3947 ft-lb 23633 ft-lb <br /> �. .-' t 1NxSuj i#'`w�'' / <br /> �i,a� ?P� Shear H3'4" rr 6 1" 0.048) 499 10109 <br /> {� <br /> s "4-.'' » Moment 0.169 3996 ft-lb 23633 ft-Ib <br /> ' <br /> CC Shear H3'7" 7 1" 0.041 418 10109 <br /> 9,4)5 Lt P t' Moment 7n 0.171 4048 ft-Ib 23633 ft-lb <br /> . re ldl <br /> C) Shear H4'2" 3rf 8 1" 0.031 311 10109 <br /> Moment 0.172 4071 ft-lb 23633 ft-lb <br /> k 61,,,s,..„''''''''- '•- •Digitally sealed Shear H4'5" air 9 1" 0.039 389 10109 <br /> Oct 25,2018 Moment 0.171 4037 ft-lb 23633 ft-lb <br /> Certification is to verify the joist/beam/truss to carry the loads " <br /> shown and/or for repair design.The applied loads, Shear 114'8" n O 1" 0.047 470 10109 <br /> dimensions,and field conditions info was provided by others. Moment 1 1 0.168 3977 ft-lb 23633 ft-lb <br /> The loads and dimensions must be verified and approved for <br /> the specific application by the project design professional. Shear H5'7" 311 <br /> 11 1" 0.078 792 10109 <br /> Moment 0 1a9 2c97 ft-I1, 92F.22 ff_Ih <br /> Notes chemicals 6.For net roots provide pr aper Man facturer Info Cscade Capital <br /> ponding S°FtiL f m prey f95'10" 1 1" Q D t,East F stf WA. 10109 <br /> Calculated Structured Designs is responsible only of the Handling&Installation Roseburg Forest Produc A <br /> structural adequacy of the component based on the 1.LVL beams must not be cut orddlled Moment 4500 Riddle By-pass Rd 01g213339ft-lb 23633 ft-lb <br /> design criteria and loadings shown. It is the a Refer to manufacturer's product Information <br /> responsibility of the customer antler the contractor to regarding installation requirements, multi-ply Rid 97489 j253)503-8097 <br /> ensure the component suitability of the intended fastening details,beam strength values,and code Horizontal loca.ity �g to center <br /> application,and to verify the dimensions and loads. apprOvalB <br /> Lumber 3.Damaged Beams must not he used APA'PR-L289, <br /> Pm <br /> 1.Dry service conditions,unless noted otherwise 4.Design assumes top edge is laterally restrained <br /> APA:PR-L289,PR-L27o.ICC-ES: <br /> 2.LVL not t0 be treated with fire retardant or corrosive 5.Provide lateral support at bearing points to avoid ESR-1210 U 1 8 S h! J <br /> lateral displacement and rotation This design is valid until 7/10/2021 <br /> Version 18.40.162 Powered by iStructT" /4 <br />