Laserfiche WebLink
VAs1-IIN ON STATE UN1vEks1TY <br /> S p o 1 _ EXTfNSiON ENERGY PROGRAM <br /> uptInsulation Certificate„for.Residential New Construction <br /> Permit#: . _ <br /> 2. <br /> House address or lot number: 3815 SHORE AVE, EVERETT WA. 98203 <br /> Walls Blown or Sprayed Fiberglass or Cellulose-Walls <br /> Type of insulation: FIBERGLASS UNFACED BATTS R-Value per Inch: N/A <br /> Manufacturer: JOHNS MANVILLE Coverage Area: N/A <br /> R-Value: R-21 Bag Count: N/A <br /> Floor Blown or Sprayed Fiberglass or Cellulose Ceiling <br /> Type of insulation: N/A R-Value per Inch: 3” <br /> Manufacturer:.N/A Coverage Area: 2,o27SOFT <br /> R-Value: NIA Bag Count: 47 BAGS <br /> Flat Ceiling/Attic Sprayed Polyurethane Foam (SPF) <br /> Type of insulation: FIBERGLASS UNFACED BATTS Density:CLOSED CELL 2LB POLYURETHANE <br /> Manufacturer: JOHNS MANVILLE Installed Thickness:2'TO MAKEAPPROX R-44 WITH BATTS "C"-- <br /> R-Value: R-38wITH R-11 OVER TO MAKE R-49 R-Value of Installed Thickness R-14 <br /> Building Component Installed: walls floor ceiling <br /> Single Rafter Joist Vaulted Ceiling F <br /> Typeof insulation: FIBERGLASS UNFACED BATTS <br /> Manufacturer: JOHNS MANVILLE <br /> R-Value: R-38 <br /> Insulation Installer: <br /> Company Name:.USI BURNHAM INSULATION Installer: MULTIPLE <br /> Installer Signature: /? �� 6Date: OCTOBER 29,2018 <br /> Phone Number: 425-881-2666 <br /> Washington State Energy Code Reference http://www.energv.wsu.edu/Documents/2012%20Res%20Enerov.pdf <br /> R303.1 Identification.Materials,systems and equipment shall be identified in a manner that will allow a determination of compliance with the applicable <br /> provisions of this code. <br /> R303.1.1 Building thermal envelope insulation.An R-value identification mark shall be applied by the manufacturer to each piece of building thermal <br /> envelope insulation 12 inches(305 mm)or greater in width.Alternately,the insulation installers shall provide a certification listing the <br /> type,manufacturer and R-value of insulation installed in each element of the building thermal envelope.For blown or sprayed <br /> insulation(fiberglass and cellulose),the initial installed thickness,settled thickness,settled R-value,installed density,coverage area <br /> and number of bags installed shall be listed on the certification.For sprayed polyurethane foam(SPF)insulation,the installed <br /> thickness of the areas covered and R-value of Installed thickness shall be listed on the certification.The insulation installer shall <br /> sign,date and post the certification In a conspicuous location on the job site, <br />