My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1609 5TH ST 2020-05-21
>
Address Records
>
5TH ST
>
1609
>
1609 5TH ST 2020-05-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/21/2020 12:04:08 PM
Creation date
5/21/2020 12:01:51 PM
Metadata
Fields
Template:
Address Document
Street Name
5TH ST
Street Number
1609
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Bjella Residence Bill Gaughren 360-620-8894 <br /> Heating System Type: All Other Systems O4eat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> InstructionsDesign Temperature Difference(AT) 47 <br /> �Everett IC 1..,;;,,,t411 <br /> dT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 2,209 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 18,777 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> select u-Factor . No selection 346 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions <br /> R-49 . :: 0.026 1,174 30.52 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions €. <br /> b., Select R-Value . ,:•. No selection --- <br /> Above Grade Walls(see Figure ll U-Factor X Area UA <br /> Instructions <br /> R-21lntermediate . 0.056 2,314 129.58 <br /> Floors U-Factor X Area UA <br /> Instructions R 38 0.025 ",150 3.75 <br /> ..0 <*; ; <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions ' Select R value . No selection --- <br /> i st a.,�•`' •.Z;;»r''''F a;R d rY ivT,, r s'ua2mmdat.C' <br /> Slab Below Grade(see Figure 1) F-Factor X Len UA <br /> Instructions ._. <br /> '-: [Select conditioning No selection --- <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions t R-10 Fully Insulated 7 $' 0.360 1,099 395.64 <br /> Location of Ducts <br /> Instructions �, ........_. __......._ __._..._.. ......._ Duct Leakage Coefficient <br /> �� Unconditioned Space . <br /> 1.10 <br /> Sum of UA 559.50 <br /> Envelope Heat Load 26,296 Btu/Hour <br /> Figure 1. Sum of UAX AT <br /> , ,,,,„,,, Air Leakage Heat Load 9,531 Btu/Hour <br /> VolumeX 0.6X ATX.018 <br /> AboveG a Building Design Heat Load 35,827 Btu/Hour <br /> ;"7": <br /> Air Leakage+Envelope Heat Loss <br /> p Building and Duct Heat Load 39,410 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 55,174 Btu/Hour <br /> Building and Duct Heat LdX 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss 1.25 for Heat Pump <br /> (3 /� (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.