W <br /> GENERAL NOTES -- I V <br /> 2X8 PT LEDGER AT WALL WITH 1/2 X 4" NAIL SHEATHING TO BLOCKS EDGE NAILING PER E <br /> ALL CONSTRUCTION SHALL COMPLY WITH THE 2012 STAGGERED LAG BOLTS AT 18"OC INTO RIM PER SW EDGE NAILING SW SCHEDULE <br /> INTERNATIONAL RESIDENTIAL CODE,2012 INTERNATIONAL JOIST.LAG BOLTS SHALL BE 2"FROM TOP OR Ei' <br /> (-)BUILDING CODE,AND THE 2012 INTERNATIONAL ENERGY BOTTOM AND 2"TO 5"FROM ENDS OF LEDGER ( /41 BEARING WALL 1 0 WU <br /> CONSERVATION CODE OF THE STATE OF WASHINGTON. 4/// � <br /> SIDING - <br /> R-408.2(WAC 51-51)UNDERFLOOR VENTILATION REQUIRES 1 SQ MECHANICAL {„t," (4 Z <br /> FT OF NET FREE CROSS VENTILATION FOR EACH 300 SQ FT OF METAL FLASHING FASTENER L' Q <br /> UNDERFLOOR AREA COVERED. 911.-- 1_11 (2)#4 HORIZONTAL , / a it <br /> REINFORCING ROD TYPICAL Q (B <br /> 7 II CONCRETE SLAB <br /> eL <br /> R-408.4 UNDERFLOOR ACCESS:MINIMUM 18"X 24"CLEAR _--`-J SW PER OPENING � � L <br /> ACCESS THROUGH FLOOR MIN 16"X 24"THROUGH EXT WALL �IIII,I� 1y,• ", _ PLAN � ///0) <br /> R-317.1 WOOD FLOOR JOIST CLOSER THAN 18"AND WOOD f II =1.11#-" VAPOR BARRIER Lu <br /> GIRDERS CLOSER THAN 12"FROM THE EXPOSED GROUND MUST , =11=11=11 <br /> BE PRESSURE TREATED, .� MSTC28 OR(2)HTT4 4"GRAVEL Q <br /> AT TWO LOCATIONS TO <br /> R-806.2 ATTIC VENTILATION REQUIRES NET FREE CROSS CONNECT FLOOR 16 X 8 CONTINUOUS THICKENED <br /> VENTILATION 1/150 OF ATTIC AREA.OR 1/300 IF 40-50 PERCENT IS DIAPHRAGM TO DECK JOISTS SLAB UNDER BEARING WALL <br /> LSTA21 W/BLOCKING CO UPPER VENTILATION. AS REQUIRED(4 TYP) W <br /> R-807 ATTIC ACCESS REQUIRES 22"X 30"MIN CLEAR OPENING INJJ' CONCRETE THICKENED <br /> A READILY ACCESSIBLE AREA 30"MIN HEADROOM,INSULATE 2X6 RAIL D2 SLAB FOOTING q <br /> AND WEATHERSTRIP I- PERFORATED SHEAR WALL DETAIL Z <br /> R-310 EGRESS OPENINGS SHALL HAVE A SILL HEIGHT OF NOT SEE LEDGER 2X2 WOOD iV 0 <br /> MORE THAN 44"ABOVE THE FLOOR WITH A MIN OF 5.7 SQUARE DETAILS PICKETS 5"OC F, - - <br /> FEET,A MIN WIDTH OF 20"ANDA MIN HEIGHT OF 24". ABOVE ROOFING MATERIAL TO BE <br /> P1 HOUR FIRE PROTECTION MID ROOF"UNDER SHINGLE"VENTING TO 7/18"OSB ROOF COMPOSITION OVER 30LB FELT <br /> R-314.3 INTERCONNECTED SMOKE ALARMS SHALL BE INSTALLED 5/4X4 WOOD DECKING WITH PROVIDED BY 518"GWB AT ------...„,„4/ PROVIDE LOWER ATTIC VENTILATION. SHEATHING.8D AT 6" \ <br /> IN EACH SLEEPING ROOM,IN THE IMMEDIATE VICINITY OUTSIDE (2)BD AT EACH JOIST ALL SIDESOC AT EDGES AND y MINIM <br /> EACH SLEEPING AREA AND ON EACH STORY. T�1 P: _ 12"OC AT FIELD / <br /> 2X8 PT JOIST it III \ I.ri / ROOF TO TOP PLATE1/1R315,1 CARBON MONOXIDE ALARMS SHALL BE INSTALLED 1 i(� CONNECTION PER / �,OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINRY OF /�I 2XB RIM �d'i , SW SCHEDULE ;; II I LI I p <br /> THE BEDROOMS. 1 <br /> 5/4 X 4 DIAGONAL A. z MAX 0000:111711111111611111116 L, /�_�Z�l,i4lil�l� <br /> BRACE FROM "-'" -� <br /> R-308.4 SAFETY GLAZING IS REQUIRED AT ENCLOSURES FOR BEAM TO WALL ' <br /> TUBS AND SHOWERS AND WHEN PLACED WITHIN 24"ARC OF I 4X10 PT BEAM WITH INSULATION BAFFLE WITH r <br /> EITHER VERTICAL EDGE OF DOOR AND GLAZING IS LESS THAN 12"MAX CANTILEVER _ <br /> �+ A <br /> 60"ABOVE FLOOR 514X4 CLEATS VENTED 2X <br /> EACH SIDE OVER POSTS I■I ! BLOCKING MIN AIR SPACE TO EXTEND <br /> II II SCUD TIGHT FITTING ..,y TO 12"VERTICALLY ABOVE <br /> M-1503 RANGE HOOD SHALL DISCHARGE TO THE OUTDOORS BLOCKING(NO VENTS) 41~ HEADER INSULATION N <br /> THROUGH A SINGLE WALL DUCT THE DUCT SERVING THE HOOD -� PER PLAN �L O <br /> SHALL HAVE A SMOOTH INTERIOR SURFACE,SHALL BE AIR TIGHT 4X4 PT POST 12 X 12 1 HOUR FIRE PROTECTION 2X6 WALL <br /> AND SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER 6X6 FOR POST CONCRETE PROVIDED BY 5/8"GM AT SHEATHING FRAMING C <br /> OVERI4 FT \ FOOTING 17 ALL SIDES NOTE GABLE ENDS THAT ARE DIRECTLY UP AGAINST PER SW AT 16"OC G T <br /> R319.1 BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS. BELOW GRADE 5 FT SETBACK SHALL HAVE NO GABLE VENTS. SCHEDULE W i <br /> MIN SIZE 4 IN WITH 1/2 IN STROKE AND CONTRASTING TYPICAL ROOF TO WALL <br /> BACKGROUND AND VISIBLE FROM STREET. CANTILEVER INTRUDING INTO 5 FT ROOF OVERHANG INTRUDING INTO <br /> 8 X 10 TYPICAL DECK SECTION C3 PROPERTY LINE SETBACK C2 5 FT PROPERTY LINE SETBACK C1 AND HEADER SECTION <br /> DESIGN CRITERIA _ <br /> FLOOR LIVE LOAD 40-FLOOR DEAD LOAD 10 <br /> ROOF LNE LOAD 25-ROOF DEAD LOAD 15 - <br /> THE GREATEST RISER HEIGHT WITHIN ANY 8D NAILS AT 6"CC PERIMETER NAILING TO SCUD <br /> WIND SPEED 85-SEISMIC CAT. D <br /> FLIGHT OF STAIRS SHALL NOT EXCEED THE NAILING TO LEDGER PARALLEL OR BLOCKING.SPACING ' <br /> SMALLEST BY MORE THAN 3/8" PERPENDICULAR PER PERIMETER BASEPLATE NAILING <br /> / ROOF FRAMING DOUBLE JOIST AT EACH STRAP PER <br /> TIGHT FIT SCUD PLAN WITH EQUAL NUMBER OF NAILING OF FLOOR PER SW SCHEDULE • <br /> L <br /> HANDRAIL 34.38" MIN HEAD CLEARANCE BLOCKING NAILS TO WALL FRAMING AND JOISTS, DIAPHRAGM f_ <br /> TO BE 8'-8" �! DO NOT NAIL INTO END GRAIN. J <br /> 112"ANCHOR BOLTS AT #4 VERTICAL AT 48"CC, ABOVE STAIR NOSE Ir ` ;�— 3/4"FLOOR W <br /> 72'OC HATH 7"MIN INTO EXTEND 14"INTO STEM STAIR TREAD BASEPLATE NAILING L U FLOOR TO TOP PLYWOOD \\ <br /> STEM WALL.2 BOLTS WALL AND 3"INTO PER R-311.5.3 PER SW SCHEDULE I PLATE CONNECTION / U) <br /> YI <br /> 3 4"FLOOR <br /> MIN PER SILL PLATE FOOTING WITH 1X8 RISER IIIA+ FLOOR JOISTS PLYWOOD PER SW SCHEDULE . <br /> WITH A MAX 12"AND STANDARD HOOK. +` '� 2X LEDGER BLOCK BASEPLATE "� p <br /> MIN 3.5"FROM EACH SHEARWALL PER <br /> END.WASHER TO BE .„ 2X12 STRINGERS(3) _I MECHANICAL SCHEDULE RAFTER OR TRUSS WITH NAIUNG FLOOR JOIST I CO <br /> FLOOR JOIST <br /> (2)18D TO EACH STUD PER SW 'I1 II PER PLAN j PER PLAN I CO <br /> 3X3X 1/4"MIN CONNECTION SCHEDULEf. t _ r <br /> _I FLOOR TO STAIRS W <br /> MIN RUN 10" I RIM JOIST �- <br /> .�. FLOOR JOIST I PERIMETER NAILS <br /> MAX RISE 7314" I /�I 1/Y GAG UNDER STAIRS PER SW SCHEDULE FLOOR TO TOP RIM JOIST ^' LOWER WALL TOP (' Z <br /> 1" r UNBALANCED i WALL FRAMING OR PLATE CONNECTION PLATE OR MUDSILL v Q <br /> III=I_•'•'' BACKFILL MUST I �/ 2X DRAFT STOP BLOCKING �A BEAM OR MUDSILL PER SW SCHEDULE Z <br /> SEE DETAIL(B2)FOR STRAP <br /> =11 1-1 11 NOT EXCEED 4 FT r BETWEEN STUDS PER PLAN Q J <br /> CONNECTION:IF APPLICABLE <br /> 1 1 1-1 1 1—I:•:' AND MUST NOT 2X4 STIFFENER a <br /> 1—III-11 h •;,• BE GREATER TYPICAL PARALLEL OR TYPICAL CANTILEVER J <br /> 111=1I1-1..;:, a THAN 45 DEG TYPICAL SECOND <br /> SLOPE PERPENDICULAR LOWER g2 WITH SHEAR TRANSFER <br /> 1I I1 I 1-;: :.•*:... O TYPICAL STAIR SECTION B3 g� FLOOR JOIST SECTION V <br /> III—I I1=1` ROOF TO WALL CONNECTION <br /> 1E111:±:111:71....-.1-1:: HAVE MIN STEM `1#4 AT TO W W <br /> III—IIII{'•;•,.' TOP AND BOTTOM <br /> § I—I I—I 1Ey'<?; 314"SUBFLOOR NAILED WITH BD AT 6' SOLID OR I-JOIST 1/2"ANCHOR BOLTS AT 72"OC 1/2"ANCHOR BOLTS AT 72"OC "J 0 <br /> o= 1 1 1-1 1 1=1' .1,, BLOCKING PER PLAN WITH 7"MIN INTO STEM WALL BASEPLATE NAILING 1/2"ANCHOR NTOS AT 72"OC <br /> _ _ WITH 7"MIN INTO STEM WALL r MIN STEM WALL D N <br /> I—I I 1-111ti"‘,".:I.,11=1,, <br /> i!-`\ OC AT EDGES AND 12"CC AT FIELD 2 WITH LA MAX MIN P2'AND MIN SILL S" 4"CONCRETE SLAB 2 BOLTS MIN PER SILL PLATE #4 VERTICAL AT SW SCHEDULE WITH <br /> BOL S MIN IPER SILL PLATE COILI�L <br /> III—I I=� :.;I-1., Ir FLOOR JOIST • END.WASHER TO WITH A MAX 12"AND MIN 3.5" 48"CC.EXTEND FLOOR TO TOP WITH A MAX 17 AND MIN 3.5" LSV <br /> II PER PLAN FROM EACH END,WASHER TO 14"INTO STEM PLATE CONNECTION FROM EACH END.WASHER TO <br /> 1-111-1I1J ::'."=-__I I—\ ar' -- "- -•"+ BE FROM EACH MIN. #4 VERTICAL AT 48" BE 3X3X 1/4"MIN. WALL AND 3"INTO <br /> _ PER SW SCHEDULE I`' BE 3X3X 1/4"MIN. <br /> 1E111—=111E:111:=1-111:7-1:•.; <br /> ( 1 11 :. 111 111 11111 BEAM PER PLAN ��/'/5!4X4 CLEATS EACH SIDE INTO <br /> EXTEND 14"WALL FOOTING WITH <br /> 4X4 POST lir MIN 9015 FELT OR PRESSURE /AND 3"S STEM <br /> PRESSURE STANDARD HOOK PRESSURE CO <br /> III—III=1,.' ''I III—III— �' " PT POST / <br /> —I 11-1 1 I-r ;F, Ilia I-1II— 8 MIL BLACK VAPOR TREATED FOOTING WITH TREATED TREATED '(I r FLOOR JOIST <br /> '111_ _ _ _ _ _ BARRIER THROUGHOUT PROVIDE A23 POSITIVE MUDSILL TYPICAL STANDARD HOOK MUDSILL TYPICAL MUDSILL TYPICAL�• 1-1 T <br /> LILA—�: ''' —111— —111— CONNECTION • 4"CONCRETE SLAB _�'_� #4 VERTICAL AT <br /> —III-1I1-,•..L-111-111— —111— CRAWL SPACE f �--I... I�,�..:. .. ..: :... y p —T5 48"OC.EXTEND W N <br /> :111-111 �:;` <1= — 1E-111_ 111— .' �;: ,t: STEM WALL �� ..,IL <br /> � L�� 3 STEM WALL 1_. I 'NAV/• A� STEM WALL r l..� <br /> IL <br /> i 3 14"INTO STEM ~ \ m <br /> 11 I-1I1 ' :X111—I 1 1—I 1 1-111—I 12"MIN REQUIREDVIE 1 'I a_ �I 1Ili / TO HAVE WALL AND 3"INTO Q CO Q <br /> I BETWEEN BEAM ',:=:.�'F.;.:;i......> TO HAVE 1 �. = TO HAVE p FOOTING WITH 0 CV <br /> 1_7_111.7.7„.1.:.....:;:(..7-111-1 I 1-1 11=1 AND GROUND.18" --11 <br /> _ _ MIN 1#4 AT "� —III—I I MN 1#4 AT '4 1 1— 6MIL BLACK MIN 1#4 AT `i <br /> 5' : ;,; _ _ STANDARD HOOK <br /> b III_ //' �•'. T1iIS FOUNDATION MIN REQUIRED IE-111—=-111E-111III—III—I 1 TOP AND I�� a TOP AND '���IICg VAPOR BARRIER <br /> TOP ANDI1165' I�I I r Q <br /> T=11 r 111-1 WALL IS DESIGNED AND ROUND.JOISTS 111=1 1—111=1 =11— BOTTOM k III L 111— BOTTOM a 1E-111 1 R-10 RIGID BOTTOM a L 1=11 <br /> 0•-g" PER R404.1.4 WITH CONCRETE SIF 11R3IIlW11— _ _ -= INSULATION WITH 4" .I 11=11 <br /> p-3".,, TABLE 404.1.1(5) PAOPERPLAN lac I. VERT AND 24" Low '6MIL BLACK UJ <br /> rat:.- + �•r HORIZ OR 24"VERT. rr VAPOR BARRIER <br /> FOUNDATION WALL TYPICAL CRAWL SPACE TYPICAL FOUNDATION TYPICAL FOUNDATION WITH TYPICAL FOUNDATION TO SHEET: <br /> A5 4'-6"TO 8'IN HEIGHT. A4 BEAM SECTION A3 AT GARAGE FLOOR O INSULATED SLAB FLOOR Al FLOOR JOIST SECTION <br />
The URL can be used to link to this page
Your browser does not support the video tag.