LEGEND GENERA� NOTES <br /> o SPRINKLER UPRIGIIi THE BOEING NERETT FIRE WSPECtION DEPARTMENT (425-342-2266) '�. <br /> • SPRINKLER PENDANT SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ALL VALVE CLOSURES, <br /> FLUSHING, AND HYDROSTATIC TESTS ON THE RRE PROTECTION SYSTEM. .. <br /> THE MARIMUM DURAfION OF A SYSTEM CLOSURE IS 8 HOURS UNLESS <br /> � OVEN SPRINKLERS (PENDANiH) PERMISSION IS GRANTED BY THE FlftE CHIEE � <br /> O DRY PENDANT SPRINKLER (PENDANTL ) A CONTRACTOR'S MAT[RIAL AN� TEST CERTIRCAIE WILL BE REQUIRED <br /> UPON COMPLETION OF THE TESTING. THF CERTIRCATE MUST BE SIGNED <br /> OFF BY THE BOEING EVERETT FIR[ WSPECTOR DEPARTMENT PRIOR TO <br /> COMMENCING ADDITIONAL WORK ON THE FlRE PROTFCTION SYSTEM. " <br /> SYMBOL ABBREVIATION DESCRIPTION <br /> -�� �� PIPE HANGERS SPACING SHALL BE PER NFPA #13. <br /> —7 PIPE CAP <br /> �� BF BLIND FLANGE ALL SPRWKLER PIPING 1 1�2" AND SMALLER SHALL BE SCHEDULE 40 <br /> c+- 90 � ELBOW DOWN ASTM A-53 BLACK STEEL. ALL PIPING 2" AND LARGER SHALL BE ASTM � <br /> o�- 90 � ELBOW UP A-53 SCHEDULE 40 FOR VERTICAL RISERS AND SCHEDULE 10 FOR <br /> — OUTLET (TEE) DOWN HORIZOMAL MAINS AND CROSS MAINS. <br /> -Fo� OUTLET (TEE ) UP SPRINKLER SYSTEM PIPE FlTTINGS SHALL BE 150 LB. THREADED <br /> {�c-+ PIPE OFFSETTING DOWN MALLEAB�E IRON FOR 1 �" AND SMALLER, AND VICTAULIC GROOVED � <br /> (W/RESPECT TO ARROW) <br /> �� PIPE FLANGE 150 LB. THREADED MALLEABLE IRON OR VICTAULIC GROOVED. <br /> — PIPE GUIDE <br /> � ANC PIPE ANCHOR COUPLINGS FOR GROOVED PIPE AND RTTINGS SHALL BE VICTAULIC S1YLE <br /> 07 ZERO-FLEX UNLESS OTHERWISE NOTED. <br /> — PIPE HANGER � <br /> TYP TYPICAL hIYDROSTATIC TEST: PER NFPA 13 <br /> DN DOWN <br /> DR DRAIN SEISMIC BRACING SHALL BE WSTALLED IN ACCORDANCE WITH FM <br /> STANDARDS. SEE FM DATA SHEETS 2-B, "EARTHQUAKE PROTECTION FOR <br /> WATER-BASED FIRE PROTECTION SYSTEMS" FOR SPECIfIC DETAILS. � <br /> i�i ASDPY <br /> , AUTOMATIC SPRINKLER HEADS SHALL BE 165 DEGREE F. TEMPERATURE <br /> RATED. <br /> � 6" MANIFOIDED DRY SPRINKLER RISER COMPLETG WITH 6" OS&Y <br /> DPV GATE VALVE, 6" DRY PIPE VALVE, PLANT AIR SUPPLY, AIR ALL EQUIPMENI SHALL BE UL LISTED AND FM APPROVED PoR FIRE . <br /> MAINTENANCE DEVICE, REfARD CHAMBER, LOW AIR PRESSURE SERVICF. <br /> SWITCH, WATER ROW PRESSURE SWITCH, 7' MAIN DRAIN, AND <br /> TWO (2) PRESSURE GAUGES WMPLETE WITH SHUT-OFF VALVES. <br /> � 6" IN-RACK SPRINKLER RISER CONSISTING OF 6" AL4RM CHECK <br /> IRST VALVE, 2" MAIN DRAIN, TWO (2) PRESSURE GAUGES WITH <br /> SHUT-OFF VALVES, AND EXCESS PRESSURE PUMP SUPPLIED <br /> WITH A 6" OS&Y GATE VALVE WITH SUPERVISORY SWITCH, <br /> SUPPLIED FROM TUNNEL FlRE PROTEC110N MAIN. A <br /> � 8" AUTOMATIC SPRMK�ER RISER COMPLEfE WITH 8" ALARM <br /> ASRT CHECK VALVE, 2" MAIN DRAIN, TWO (2) PRESSURE PUMP, WATER <br /> MOTOR GONG AND 8" GAUGES, EXCESS PRESSURE OS&Y GATE <br /> VALVE WITH SUPERVISORY SWIfCH, SUPPLY FROM TUNNEL FlRE <br /> . PROTECTION MAIN. <br /> � 8" AUTOMATIC SPRINKLER RISER COMPLETE WITH 8" AL4RM ' <br /> ASRU CHECK VALVE, 2" MAIN DRAIN, TWO (2) PRESSURE GAUGES, <br /> �� EXCESS PRESSURE PUMP, AND WATER MOTOR GONG. SUPPLY <br /> FROM THE UNDERGROUND FIRE PROTECTION MAIN. <br /> � 6" HOSE STATION STANDPIPE RISER COMPLETE WITH 2° MAIN <br /> HRU DRAIN, AND PRESSURE GAUGE WI1N SHUT-OFF VALVE SUPPLIED . <br /> FROM THE UNDERGROUND RRE PROTECTION MAIN. ' <br /> � � 6" HOSE STATION STANDPIPE RISER COMPLETE WITFI 2" MAIN <br /> HRT DRAIN AND PRESSURE GAUGE WITH SHUT-OFF VALVE, SUPPLIED <br /> FROM TUNNEL FIRE PROTECTION MAIN. � <br /> RH ROOF HOSE STATION COMPLETE WITH ONE (i) 2 1/2 " GATED <br /> RFH HOSE VALVE AND TWO (2) 1 1/2 ° GATED HOSE HOSE VALVES, <br /> COMPLETE WITH 4" NON-RISING SIEM GATE VALVE, 1 " DRAW � <br /> VALVE, AND ROOF ENCLOSURE. <br /> � INTERNAL FlRE HYDRANT CONSISTING OF A 4" OS&Y VALVE AND <br /> IFH 5°(INCH) °STORTZ" CONNECTION COMPLETE WITH CAP AND CHAIN <br /> � FIRE HOSE STATION CONSISTING OF 1 1/2" BRASS ANGIE VALVE <br /> COMPLEiE WITH PRESSURE REDUCWG DISC, ELKHART N0.24 <br /> HYDROLATOR VALVE, 150 FEET OF 1 1/2" ANCUS RED FIHE ' <br /> CMEF HOSE IN THREE(3), RFiY(50) HOSE NOZZLE. FOOT <br /> LENGTHS AND 1 1/7' BRASS ADJUSTABLE CABWET SHALL BE <br /> STEEL WITH A SOLID STEEL DOOR, AND SHALL BE SURFACE <br /> MOUNTED. <br /> � 212 UEGREE F, 1/2" ORIFlCE, HORIZONTAL, BRASS SIDEWALL � <br /> SPRWKLER SUPPLIED FROM THE DRY PIPE SYSTEM WSTALLED <br /> ON AN ORDINARY HAZARD PIPE SCHEDULE BASIS. SUPPLIED <br /> FROM DRY PIPE SYSTEM LOCATED NEAR COLUMN "P"-"5". <br /> � 212 DEGREE F, 1/2" ORIFICE, DRY HORIZONTAL, BRASS ' <br /> SIDEWALL SPRMKLER SUPPLIED FROM THE EXISTING WET PIPE � � � � n ' <br /> SYSTEM INSTALLED ON AN OR�INARY HAZARD PIPE SCHEDULE /� i v <br /> BASIS. SUPPLIED FROM WET PIPE SYSTEM LOCATED SOUTH OF Yi <br /> cowMN uNE "s". G R O U P <br /> 17429908 - WBS 2.2.3.4.1 soo Stewart st., ste 1400 <br /> IFC SUBMITTAL Seattle, Washington 98101 <br /> 09.21 .16 �� rei 206.267.1700 <br /> Fax 206.267.1701 <br /> SAZAN # 500-1532 <br /> STM REVISION BY NPPROVED �NiE STM I PEVISI�N � BY APPROVED �� OAiE ��YV�� �RAWN F➢ATE SUBTRLE CUNNEN! HLVISION SYMBOL �Ai[ <br /> � F L . � ACCEPTABILIiY <br /> p� „ � t �„ �k FIRE PROTECTION GENERAL NOTES AND LEGEND 17429908 oe2i .ie <br /> �/ -i � • iHIS DESIGN AND/OR <br /> A WBS 2,25,1 ,13 - AUiOMAiEO �IE-CLFANING 17429908 SAZAN W21.16 � �� SHE� <br /> ♦ SPFCIFlCAiION IS APPROVEO <br /> _ ..� ��O`��//� � .; � f ,ti� �� � navrewco er oear. ontc �'��F WBS 22.3.1 .13 - AUTOMATED DIE-CLEANING 1 M260-G1 <br /> � /�fI � / !4� - cH[ckEo <br /> �. a„R� ,�E AP R BUILDING 40-056 ��a �� ���P �� <br /> �'� ...:%:� <br /> osrzorzots A E0 MECHANICAL MASfEH COL CC-C/3-4 EVEREfT, WA °`"c rvo. q0-056-1M260-G1 <br />