Laserfiche WebLink
� ��:� ��� �,�,, <br /> + � �, <br /> . • � <br /> � •i. <br /> � � ' <br /> S <br /> � � � <br /> PANDA EXPRESS, INC. <br /> 1683 Walnut Grove Ave. <br /> Rosemead, California <br /> 91770 � <br /> Telephone:626.799.9898 � <br /> Facsimile:626.372.8288 � <br /> — ---- -- --- -- ---- _ _----__ - -- - <br /> - - All ideas,designs,arrangement and plans indicated or <br /> _ _ _ -- _ - - <br /> 2 0 - 16 _ represented by this tlrawing are the property of Panda <br /> 4 Express Inc.and were created for use on this specific project. • <br /> Scale: NO SCALE M-501 Scale: NO SCALE M-501 M-501 None of these ideas,designs,arrangements or plans may be <br /> Scale: NO SCALE used by or disclosed to any person,firm,or corporation <br /> without the written permission of Panda Express Inc. <br /> yi <br /> i <br /> � EXHAUST FAN, SEE SCHEDULE& REVISIONS: � <br /> CAPTIVEAIRE DWG <br /> Health Dept.PC#1 06/15/18 VK/VZ <br /> l GREASE CUP 0 Building Dept.PC#1 08/07/18 VK/VZ , <br /> ELECTRICAL FEED TO BE T � Q Panda Modifications 11/20/18 VK <br /> INSTALLED ON HINGE SIDE OF � Bldg.Dept.PC#2 01/14/19 VZ <br /> UNIT.PENETRATE ROOF VIA TRANSITION FROM RECTANGULAR • <br /> PITCH PAN. DO NOT PENETRATE DUCT TO EXHAUT FAN AIR INLET <br /> ROOF CURB. OPENING ABOVE ROOF BY � <br /> MECHANICAL CONTRACTOR. SEE � <br /> CAPTIVEAIRE DWG FOR SIZE. <br /> }f• <br /> VENTED CURB, SEE CAPTIVEAIRE <br /> DWG • <br /> RooF ISSUE DATE: , <br /> EXHAUST DUCT FROM HOOD f <br /> � CEILING <br /> � FIRE RATED DUCT ENCLOSURE � <br /> ' OR FIRE RATED DUCT WRAP, <br /> SEE CODE COMPLIANCE DWG <br /> :�• <br /> � � 9 - 15 - 7 GREASE EXHAUST FAN DETAIL 3 �� : <br /> Scale: NO SCALE M-501 Scale: NO SCALE M-5O� Scale: NO SCALE M-501 Scale: NO SCALE - DRAWN BY: LMR ENGINEERS " <br /> M 501 <br /> � RTU UNIT <br /> PANDA PROJECT#: S5-19-D5892 '� <br /> GASKET(SUPPLIED 2"wIDE-18GA. G.I. LMR PROJECT#: 1891 <br /> W/CURB) ANCHORS. SECURE <br /> TO UNIT W/(2)#14 SMS - <br /> NAILER STRIP MIN. (4) PER UNIT <br /> r��'P4��5���'�����t;' , <br /> ' 26 GA. G.I. COUNTER ��tq '';'� '�'� � <br /> ' FLASHING <br /> � ROOFING FELT BY OTHERS � ��'Cl2lteCtS � PlC11272�Y'S � <br /> Inc. <br /> DUCT CANT STRIP BY OTHERS '� . <br /> ROOFING BY OTHERS <br /> � 5800 Stc�nfoi�d R�anch�Roacl Siiite 720 <br /> � � � � Rociclin, CA 95765 <br /> � • PRE-FAB CURB -�-�� phone: (916) 451-I500 - fc��: (916) �S I-.1600 � �'���� <br /> ROOF STRUCTURE STAMP: � E ' <br /> SEE STRUCTL DWG'S "���� Pi � <br /> rr� t <br /> � ���,� �, w� , <br /> 18 - 14 � � �� �� � ����� � � ��� <br /> � . RT U U N I T C U R� D E TA I L 2 ��������� � ���� <br /> � � , � � . <br /> Scale: NO SCALE M'50'� Scale: NO SCALE M'S�� , � �` ��' �� � <br /> 7 4 Scale: NO SCALE M_50') <br /> �� ��� ',, <br /> SEQUENCE OF OPERATIONS: LEGEND ' ���"���� <br /> UPON ACTIVATION OF THE KITCHEN HOOD 6 <br /> ANSUL SYSTEM,THE DRY CONTACT WITHIN C2 FROM EXISTING � � � ������� ������-��� ��� � , <br /> CAPTIVE AIRE PANEL 2 #12 CONTROL WIRES IN 1/2"CONDUIT BY E.C. <br /> THE HOOD CONTROL PANEL SHALL OPEN AND � _ ' <br /> SEND A CONTROL SIGNAL FOR ROOFTOP UNIT R2 O2 M.C.TO CONNECT INTO REMOTE UNIT SHUTDOWN TERMINAL ON � . <br /> SHUTDOWN.SHUTDOWN SHALL OCCUR VIAAN AR2 CARRIER ROOFTOP UNIT CONTROL BOARD AND REMOVE JUMPER. . <br /> ISOLATION RELAY TO THE(3)ROOFTOP UNITS REFER TO MANUFACTURER FOR ADDITIONAL INFORMATION. C FT P LALA � <br /> SUPPLYING MAKE-UP AIR TO THE HOOD.E.C. <br /> • � TO PROVIDE CABINET,RELAY,TRANSFORMER � 6 � 2 O3 DPDT 120V RATED RELAY BY E.C.ENERGIZE FOR FAILSAFE E�E RG RE E N WAY � <br /> AND ALL NECESSARY CONDUIT AND WIRING IN OPERATION. <br /> ORDER TO PROVIDE A,COMPLETE,FULLY � <br /> FUNCTIONING SYSTEM. T O4 HOOD CONTROL PANEL AT KITCHEN. ' EVERGREEN WAY & CASINO ROAD � <br /> H R1 � O5 12X12X6 NEMA 1 CABINET MOUNTED ON WALL ADJACENT TO EVERETT, WA 98208 <br /> CONNECT T0120V KITCHEN HOOD BY E.C. - � <br /> CIRCUIT FEEDWG 120V R1 <br /> HOOD CONTROL PANEL O6 N.O.DRY CONTACT(SHOWN ENERGIZED)THAT OPENS IN FIRE '�' <br /> N e coN�irioNs. � DT END CAP TENANT IMPROVEMENT <br /> R1 # <br /> • O 120V RATED DRY CONTACT WITHIN CAPTIVE AIRE PANEL. <br /> . _ � <br /> R1 T , <br /> #e Scale: NO SCALE M-5o� <br /> � +. <br /> 5 3 6 � I�VU� <br /> CONSULTING MECHANICAL ENGINEERS <br /> _ � � � 13 RTU CONTROL WIRING DIAGRAM 5 1165ASTREETHAYWARD, CA 94541 MEC � <br /> HAN CAL DETAILS � <br /> M_^O� TEL. (510) 733-2330 FAX. (510) 733-0332 <br /> Scale: NO SCALE _5�'� Scale: NO SCALE M-50'� Scale: NO SCALE � � WWW.LMRENGINEERS.COM <br /> PLANCHECK SUBMITTAL DWGS 1891 � <br />