Laserfiche WebLink
. . . . . . � . . � 1.� <br /> 1. ALL ROOF MOUNTED EQUIPMENT SHALL BE IN NEMA-3R �•-��==���T � � <br /> ENCLOSURES. ,,,.�� ``� µ�� <br /> P► EX .� <br /> 2. ALL CONDUIT RUNS SHOWN ON THE ROOF SHALL BE RUN BELOW NOTE £''� � .F A � <br /> � � a <br /> THE CEILING SPACE WHERE AMBIENT TEMPERATURE WILL BE ���; `T'� <br /> � � i ..��� . <br /> BELOW 30° C. FINAL CONNECTfONS TO THE ROOF EQUIPMENT IS CONVENIENT RECEPTACLES WILL BE ; ��';�}� � � <br /> FACTORY INSTALLED ON RTU'S UNITS -�-� '��� <br /> LIMITED TO 5'-0'OF DIRECT SOLAR EXPOSURE. AND POWERED VIA CIRCUIT 8-29. � ����_ ���� � <br /> 3. NOT USED. � .���`�t �� � , <br /> . � '�;��� O 4 .. <br /> ? �� � <br /> 4. VERIFY ALL FUSE SIZES AND TYPES WITH THE AIR CONDITIONING , ��' � i <br /> EQUIPMENT MANUFACTURER PRIOR TO INSTALLATION. � � ,� <br /> 5. REVIEW THE MECHANICAL PLANS FOR THE AIR CONDITIONING - � ��TLv-O� � ��/ -� ;,� <br /> CONTROL REQUIREMENTS AND SCOPE OF WORK PRIOR TO BIDDING :�� v �,< L: ' <br /> AND INCLUDE ALL COSTS IN BID. �R� �`� �° <br /> ��.� ET C <br /> �.Y . <br /> - <br /> 6. VERIFY CONNECTION POINTS OF ALL HVAC EQUIPMENT PRIOR TO �<�,. =�' , <br /> INSTA�LATION. PROVIDE CONTROL VOLTAGE CONNECTION TO DUCT <br /> MTD. SMOKE DETECTOR AS REQUIRED BY MECHANICAL DRAWING - � PANDA RESTAURANT GROUP INC, <br /> M-100. _ <br /> � � 1683 Walnut Grove Ave. <br /> 7. SEE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF �� � ^ ROS@I112aCI, Califomia <br /> MECHANICAL EQUIPMENT AND THERMOSTATS. PROVIDE RACEWAY � <br /> SYSTEM FOR ALL CONTROL WIRWG AS REQUIRED BY MECHANICAL 91770 � <br /> DRAWING M-100. _ _ Telephone:626.799.9898 <br /> � Facsimile: 626.372.8288 <br /> 8. G.C. COORDINATE ELECTRICAL, MECHANICAL, FIRE ALARM (IF �Q - ,;. <br /> REQUIIRED) FOR INTERLOCK SEQUENCE. . <br /> . � . � O �'...,L. <br /> 9. RESTROOM EXHAUST FAN TO BE POWERED FROM BACK OF HOUSE � - ' <br /> LIGHTING CIRCUIT. SEE DETAIL 5/E400 FOR ADDITIONAL <br /> All ideas,tlesigns,arrangement and plans indicated or <br /> INFORMATtON. -�� represented by this drawing are the property of Panda <br /> '`�� Express Inc.and were created for use on this specific project. • <br /> ��� <br /> None of these ideas,designs,arrangements or plans may be <br /> ROOF PLAN GENERAL NOTES 2 ���'� ± <br /> �~�� used by or disclosed to any person,firm,or corporation <br /> �'`�� without the written permission of Panda Express inc. <br /> NOT TO SCALE E'1 O4 `�``��_ � <br /> `'�� <br /> � <br /> ��� <br /> �--_.. <br /> � �-�...., <br /> REVISIONS: DATE: BY: <br /> EF ��� ;",. <br /> �89 Ibs ac �E) 0 ' , . <br /> � / -,- � � �� � <br /> 1. ROUTE HOMERUN THROUGH BACK OF HOUSE LIGHTING CIRCUIT. � 3 � 2 1504 Ibs �_�� � 0 ` . <br /> REFER TO LIGHTING PLAN, SHEET 1 /E-101. FAN TO BE CONTROLLED 7 i���� C ( 0 <br /> BY SWITCH FOR BACK OF HOUSE LIGHTING. ii `� �' _ Q " <br /> �- - � 0 <br /> 2. DUCT SMOKE DETECTOR. FURNISHED BY MECHANICAUFACTORY, / \ Q ' <br /> WIRED BY ELECTRICAL/FIRE ALARM CONTRACTOR. FURNISH AND <br /> INSTALL ALL RACEWAY, WIRING,AND ADDITIONAL ACCESSORIES `��., � 0 <br /> REQUIRED FOR CODE COMPLIANCE AND UNIT SHUTDOWN. / ��'_�'� ',,,I - s • <br /> � . <br /> 3. CIRCUIT FEEDS FROM PANELBOARD-THROUGH HOOD CONTROL 1 (E) � (E) <br /> PANEL- UP TO ROOF. REFER TO DETAIL, SHEET 3/E-401 &KITCHEN GFCI WP - <br /> HOOD SUBMITTAL DATA. �NP <br /> O 'B'37-39-41 E A-74,76,78 � 6 � �SSUE �ATE: ;i=� <br /> 4. REFER TO CONDENSING UNIT WIRING DIAGRAM, SHEET 7/E-400. - s---- � � 4 �sT ' <br /> 5. STRUT RACK SUPPORT FOR EQUIPMENT DISCONNECT SWITCHES. , r{� � 2N° " <br /> � <br /> REFER TO DETAIL, SHEET 2/E-401. � A� (E) :�.� � sRo � <br /> _� �1504 Ibs �,-' 4TH <br /> 3 � <br /> 6. PROVIDE AND INSTALL 2-1/2" DIA GALVANIZED RIGID METAL CONDUIT 5TH ` <br /> AND WEATHERHEAD AS SHOWN. CONDUIT TO BE STRAPPED TO � i ��` �-- <br /> CLOSEST JOIST TO THE MANAGER'S STATION (FULL DEPTH). - <br /> 6TH <br /> � � � �rH , <br /> 7. DO NOT INSTALL UNTIL BACK DRAFT DAMPER INSTALLATION IS Q � <br /> COMPLETE. UTILIZE FACTORY KNOCKOUTS FOR ELECTRICAL RUN FO � (`�,%� �E� L� <br /> THIS FAN. REFER TO SHEET M-401. ���_ � ,,'�,� A� <br /> -,.,_ G � 8941bs <br /> 8. MOUNT PHOTOCELL AS DETAILED ON SHEET 11-E400 ON CONDENSER �iE� � 'B' 38,40,42 '''' <br /> Ra,cK. ; �P� ` �' wP � 3 �E� DRAWN BY: CRM Architects & Planners, Inc. � . <br /> 0 � <br /> 9. STUB ELECTRICAL FEED FOR EF-1 & EF-2, THROUGH ROOF ON HINGE � ���t` � <br /> SIDE OF EXHAUST FANS, IN LOCATION AS SHOWN ON POWER ROOF �� . <br /> PLAN. REFER TO DETAIL 3/M-501 FOR ADDITIONAL DETAILS. #g �E� <br /> WP PANDA PROJECT#: S8-18-D5892 <br /> 10. FEED THROUGH FACTORY THRU BASE CONNECTION AREA. (E)A-68,70,72 � I <br /> COORDINATE WITH MECHANICAL. j ARCH PROJECT#: CRM 1756 <br /> � , <br /> 11. UNIT WCLUDES FACTORY MOLDED CASE DISCONNECT SWITCH (NO (E)A-53 , #10 <br /> OCP). VERIFY WITH MECHANICAL SUBMITTAL DATA. PROVIDE ( <br /> DISCONNECT IF/AS REQUIRED. (E)A-80,82,84 <br /> r ��i �� <br /> # - �' - � y; � <br /> O ROOF PLAN KEYED NOTES 3 ,8,24 � /�A�chitects & Planne�s `� . <br /> ����Vl Inc. <br /> NOT TO SCALE E'104 � «-�--� � <br /> � . <br /> � r <br /> 10J ���- 5800 Stanford Ranch Road Suite 720 <br /> 203 Ibs Rocklin, CA 95765 • <br /> � ZF 184 I s � EF 184 I s phone: (916) =�51-1 S00 - fc�: (916) 451-1600 <br /> ROOFTOP EQUIPMENT SCHEDULE � �. � � ,,-.---_� /� 5 <br /> �.� ,:. <br /> MOUNT DISC. SW. WITH RK1 FUSES PER '�� <br /> TAG DESCRIPTION kW H.P. FLA VOLT/� WIRE, CONDUIT CONN. HEIGHT MFR'S REQ'S. AND/OR REMARKS ~� �!'� STAMP: F,R� � /VR/,f- <br /> AC1 (E)A/C UNIT 26.5 208V.3QJ 3#10, #10 GND., 1"C. �-' AT UNIT 40A. 3P. 3F. WP O 4O � <br /> / � dtIA4A�1E1Y1n �G�`o� S y��y <br /> r�� , �. � � <br /> O3 'B' 32-34-36 O3 B'26-28-30 �c�A�ser�cr.�ivr� v' <br /> AC2 (E)A/C UNIT 52.0 208V.3Q1 3#6, #10 GND., 1"C. �-' AT UNIT 60A. 3P. 3F. WP 1O 4� 'A' 56,58 9 9 �0555 o�d P�acervi��e Road <br /> 4 Socramsnto. CA 95827-2503 "O 3Q4g5 <br /> AC3 (E)A/C UNIT 52.0 208V.3�'Q 3#6, #10 GND., 1"C. 0-' AT UNIT 60A. 3P. 3F. WP 1 4 � O _ Phone: (916) 368-4468 � �F� ��,� �, <br /> OO X F�www9sace�c�� Ss� �STE G�� <br /> 31-S 10J-S1 32-S1 ,�-� "g °'" ONAI E� <br /> O4 �� 223 �bs 203 Ibs 197 Ibs ��b�. 18315 ExP�REs �o-2a-2o2o � <br /> CU-1 CONDENSING UNIT 40.6 208V.3QJ 3#6, #10 GND., 1" C. �-' AT UNIT 60A. 3P, 3F. WP 1O " '64,66 O � -z'1---i--- Date �igned: february 21, 2019 <br /> 4 <br /> �� �� �� <br /> MA-1 MAKE-UP AIR UNIT 5.0 15.0 208V.3QJ 3#12, #12 GND., 3/4"C. �-' AT UNIT O O4 �``�--.,.�� 'A'60,62 $ 5 �--, � .;;. <br /> ��� �� C F T P LAZA �L , <br /> EF-1 EXHAUST FAN 2.0 5.9 208V.3Q1 3#12, #12 GND., 3/4"C. �' AT UNIT 1� ```'`�_ E V E R V R E E N W A Y <br /> EF-2 EXHAUST FAN 2.0 5.9 208V.3flJ 3#12, #12 GND., 3/4"C. �' AT UNIT 1� C�> EVERGREEN WAY & CASINO ROAD .� <br /> EF-3 EXHAUST FAN 1/4 4.8 120V.1 fd 2#12, #12 GND., 3/4"C. �' AT UNIT 30A: 2P. 1 F. WP 1��4 <br /> J �, EVERETT, WA 98208 <br /> �� � <br /> I \ . <br /> 31c W/i COOLER COND. 1.5 10.0 208V.10 2#12, #12 GND., 3/4"C. �-' AT UNIT 2 3 - ��_ ^ �__ DT END CAP TENANT IMPR�VENIENT <br /> 32c W/I FREEZER COND. 1.5 10.0 208V.1fd 2#12, #12 GND., 3/4"C. �-' AT UNIT 2 3 <br /> r:� <br /> 10J-S1 ICE MACHINE COND. 11.7 208V.1QJ 2#12, #12 GND., 3/4°C. � AT UNIT 2 3 . <br /> 1ODISCONNECT SWITCH PROVIDED WITH UNIT. - <br /> 2�COMBINATION 30A. 2P. 2F. WP DISCONNECT SWITCH WITH RK5 FUSES PER MANUFACTURER RECOMMENDATION. ' <br /> OEOo BINE CIRCUITRY IN 1"CONDUIT FROM J-BOX ON EQUIPMENT DISCONNECT SWITCH SUPPORT. REFER TO DETAIL THIS SHEET, 1 / <br /> � <br /> OELECTRICAL FEEDS ARE TO BE ROUTED FROM PLENUM SPACE, UP THROUGH EQUIPMENT CURB, INTO BOTTOM OF EQUIPMENT, <br /> THROUGH FACTORY INSTALLED WATER TIGHT CONNECTIONS. <br /> HVAC EQUIPMENT SCHEDULE 4 ROOF POWER PLAN ROOFPOWERPLAN � <br /> 1 <br /> NOT TO SCALE E''� OL�, 1/4" = 1'-0" E-'� OLI. �,,. <br /> PLANCHECK SUBMITTAL DWGS <br />