Laserfiche WebLink
.� ..�..�...,.�1., . .... .. . _ . . . _ . . . . . . . . . . . . . . . . <br /> __. ._. _ _ - _ .__' - . .. �.:.�5�. <br /> GENERAL NOTES c� �- � <br /> � � <br /> 1 THIS DRAWWG PORTRAYS BUILDING ELEMENTS IN DIAGRAMMATIC FASHION AND IS _I o <br /> NOT TO BE A PICTORIAL REPRESENTATION OF BUILDING ELEMENTS. � �' <br /> 2 EXISTING AREAS SHOWN IN THIS DRAWING ARE UNALTERED AND SHAI,L NOT BE t!a � . <br /> CONSIDERED AS NEW,ADDED OR ALTERED SPACES UNLESS INDICATED. (�,) • <br /> 3 EXISTING AREAS AND NEW ADDITIONS ARE INDICATED BY HATCH PATI'ERNS. � � � <br /> ALTERED SPACES ARE NOT INDICATED BY SUCH PATTERNS. `° = <br /> � N C6 <br /> 4 DIMENSIONS ARE MEASURED TO THE FACE OF FINISH. � � o, �'._ <br /> 5 BUILDING ELEMENTS,NEW AND EXISTlNG,THAT APPEAR TO ALIGN ARE INTENDED TO � �� � <br /> ALIGN, UNLESS NOTED OTHERWISE. � � �' - <br /> L �'_ - <br /> � ` <br /> � � <br /> 16'-6" 2'-0" 5'-6" r/,4�� O � o <br /> ��,� l� _ SYMBOLS LEGEND � � � <br /> 6'-3" 10'-3° i „ �" E <br /> �-,�i���-- AREA OF EXISTING HOUSE:NO NEW WORK IN THIS AREA � o . <br /> I p �...��"'"- . t6 � <br /> i � V � <br /> �1 ,��/� � � o .- <br /> �p AREA OF NEW ADDITIONS � � <br /> I �r V � ' ��� � � <br /> 5040 SLDR � 4x10 HDR i �� � � ��� i � `–° <br /> ���� .� � ; <br /> %� � , A' �(� � � <br /> � •, <br /> �'�,�d j� EXISTING WALLS � <br /> , _y (�,�{�/{y�'''/ ��� NEW WALLS:WOOD SIDWG ON 1l2"PLYWOOD SHEATHING ON 2x6 STUDS � o = <br /> �/ Cy <br /> � � B� �� i �Q� 16"ON CENTER WITH R-21 BATT INSULATION AND 1/2"GYPSUM WALL- � ��� <br /> o �, B� I N � � <br /> �""" BOARD. RIGID R-10 INSULATION ON EXTERIOR FACE OF HEADERS. `- <br /> o ti � � � <br /> . <br /> - � 5040 BLDR/ 4x10 HDR ,i �6�I��UR1��N���lP��1��4���I�Po-I�T7"l�IND <br /> � � <br /> cn DN 2R � � � 1/2"GYPSUM WALLBOARD. <br /> � <br /> � O� � <br /> O <fl <br /> � �� - - =o � A1 � "' .. <br /> WINDOW <br /> `n �� o o� � <br /> N01 �v � �N � o - DIMENStONAL CENTERLINE <br /> i MASTER o EXISTIN E ISTING � � DN 1 R �, � � <br /> BEDROOM <br /> 6036 SLD DR �� - - e DOUBLE STUDS/DOUBLE CRIPPLE , <br /> � <br /> �" FAMILY � DESIGNATOR:X=EXISTING N=NEW . <br /> �l�.{�� Y�N� C-G�� <br /> , � , ROOM � <br /> �„t���A 1J1'��N'�'�0'� �� o ; <br /> A1 A2 a � cn "' X99 ROOM NUMBER <br /> � HALL-�— DESCRIPTNE ROOM NAME <br /> 2'-0" 3'-9" 2'-0" 5'-0"VERIFY � ' � <br /> NO2 _ � ' � P+S POLE AND SHELF <br /> i o <br /> ` E1 BEDROOM 2 ' i � • <br /> ALIGN 3 3 � `� � A�Pf�C7�/EU . <br /> 0 <br /> -- � � PLA1�1Nih1C� � COMMUiV17Y NUMBERS INDICATE SIZE OF DOOR LEAF WIDTH AND <br /> = i � D�V�' O�PJ�ENT D��'T. HEIGHT IN FEET AND WCHES.2668=2'-6"x 6'-8" <br /> � E� � � 2668 <br /> n � o i i i i o I a N 3 ' 3 � --. ""` SWING DOOR <br /> 7;� <br /> N � i i � � E1 E1 o C3A� E .�- .�1� . <br /> � � � I � � � � DN 1 R o 2> BIFOLD DOOR . <br /> , � � � � , _� � . LANNlNG DEPT. i�iSPECT�O�R�p�11R�� `��� <br /> +' ) `ri i i i � I `+' E1 �� NO3 B1 � _ � . <br /> a � 3 �� , M HALL No6 � _ �'RIOFt TD REQUES7 FO€t FINAl.I�dSPE�`!"i0N <br /> 3 i � EXST �� 2468 PKT 2668 BEDROOM 4 0 `� <br /> o �' Landscaping,�.Fencin� �i�ns 2668 <br /> � � EXST EXST 2668 24° � � Enviro mentaliy S�nsitiv� r�� - �� POCKET DOOR <br /> � r -� � r-- � �' � �V lh r � � .�. � IF� �A'�-(/�ti� � <br /> � � E3 � - E1 N04 +' i i � � q, 3 �' Conta ' ' �,. � � LAVATORY <br /> - - - �_ � `� � � CLOSET a . <br /> ` �o�\�p�.�� ����� � � ����, VANITY CABINET <br /> 0 �� � <br /> X05 TOILET <br /> = BATH ,� 2030iCSMT 50 SLDR i EXISTING <br /> N �1' X07 z 4x1 HDR E4 GARAGE , <br /> �, BEDROOM 3 N o N05 I DOOR HDR <br /> X06 W= POWDER . <br /> ROOM i i BATHTUB <br /> BATH EXST �Q 3�_�,� . <br /> Z J <br /> F-C� <br /> (/�p <br /> w,� 6'-10° 2'-9�� 5�_6�� - <br /> �r> p0 <br /> \ 4'-0" 2'-3" 8'-9° 8'-6° 2'-6" 4'-0° 0 <br /> Z N �.. <br /> � � � <br /> D1 D1 � <br /> X04 EXST I ( O <br /> DINING ROOM _ 020 FIXEd 4x10 HDR 5020 FIXED � 4x10 HDR 5020 FIXED 4x10 HD X9 KEYNOTES LEG E N D � o � j� � <br /> � � � � <br /> � � � � � w , <br /> �„� A1 TYPICAL FURRING ABOVE WINDOW OR DOOR HEADER Q � � <br /> �3j�,(,�/�/�,�Yj ���� �(,,��/� �/�fsf'`� D1 D2 D2 D2 D2 � A2 TYPICAL FURRING BELOW WINDOW SILL Z z � <br /> �f�J�„��'f�� �{fJ(,F1(,JJ/d-��► 61 HANDRAIL. SEE STAIR SECTION B/A3.2. � W = <br /> D2 D2 � � � <br /> B2 WOOD STOOP AND STEPS. � <br /> NO WORK IN C1 18"X 24"CRAWL SPACE ACCESS HATCH. n � � . <br /> - - BRACED WALL PANEL.2 PLYWOOD SHEATHWG(CS-WSP)AS PART OF CONTINUOUS �"�' <br /> THIS AREA � �� SHEATHING(IBC TABLE 302.10.3(3)). FASTEN WITH 8D COMMON NAILS AT 6 WCHES ON � � � <br /> � � CENTER AT EDGES AND 12 INCHES ON CENTER WITHIN THE FIELD(IBC 602.10.4). � W <br /> i� <br /> D2 1800 POUND CAPACITY HOLD-DOWNS AT BUILDING CORNER AND AT EACH END OF � � • <br /> 3 BRACED WALL PANELS. _ � ; <br /> X03 q N08 . <br /> KITCHEN N GARAGE � O <br /> X01 E1 NEW SMOKE DETE TOR&AUDIBLE FIRE ALARM PER NFPA 74. � W , <br /> LIVING ROOM = E2 OT SED. <br /> � E3 REPLACE EXISTING FAN WITH NEW WHOLE HOUSE FAN. 10<90 CFM. 1.4 CFM/WATT. <br /> X <br /> � E4 NEW WHOLE HOUSE FAN. 10<90 CFM. 1.4 CFM/WATi'. <br /> - � PERMIT <br /> o , <br /> `° ' DRAWINGS � <br /> CV O <br /> � ENERGY CODE NOTES <br /> � D2 <br /> D2 <br /> STORAGE 1 ONLY AREAS OF NEWLY HEATED AREAS(ADDITIONS AND ALTERATIONSj. EXISTING '`-' <br /> � D1 D2 D2 � D2 D2 � AREAS OF HEATED SPACES NEED NOT COMPLY.(R101.4.3) ' � <br /> � 0 16'x 7'OVER EAD DOOR 2 AREAS OF NEWLY HEATED AREAS(ADDITIONS AND ALTERATIONS)=693 SQ. FT. , <br /> 164(MASTER BEDROOM ADDITION)+89(LINKING ADDITION)+440(ALTERATION) <br /> --- --- -------------------- ---------- :. <br /> ,, 3 ENERGY CREDITS(406.2):SMAIL DWELLING(ADDITIONS UP TO 750 SQ:FT.)=0.5 <br /> 4x10iHDR 4 x 14iHDR �j� � � CREDITS REQUIRED. <br /> PROPOSED OPTION 1A: R-38 UNDER FLOOR INSULATION+U VALUE OF DOORS AND <br /> D1 D1 <br /> WINDOWS=0.28. <br /> i � 4 PROPOSED WALL INSULATION 3 3-1-2017 BCR1 <br /> 4'-0" 1'-6" 12'-6" 8'-0" 4'-0" NEW ADDITIONS:R-21 BATT INSULATION WITH INTERMEDIATE FRAMING. '. <br /> AREAS OF ALTERATION:R-13 BATT INSULATION IN EXISTING FRAMING+R-10 RIGID REV DATE TITLE <br /> INSULATION IN FURRED FRAMING. <br /> 30'-0" 5 PROPOSED CEILWG INSULATION: R-49 BATT INSULATION. DRAWN:JAM QC:JAM <br /> DATE: 1-12-2017 �3. <br /> PROJ. N0: 2016-11 � <br /> HOUSE FLOOR <br /> PLAN . <br /> GARAGE FLOOR � <br /> P LAN <br /> . . . . . i .. �,':3.. <br /> HOUSE PLAN GARAGE PLAN � � <br /> 0 <br /> A SCALE 1/4"=1'-0° SCALE: 1/4"=1'-0" Z <br /> ■ . <br />