Laserfiche WebLink
' ' 2006 Washington State Nonresidenlial Ene y Code Com ��ance Form <br /> • � ' • <br /> 1006 Wasningmn Slale Nomesbental Erergy CaOe Canplance Fom�.s R�"^seE��H 2O07 <br /> Pro]ect Info P�oject Address Northwet Mimal C�v� 6oepital-11ee�emry Buildinq Date �/?/Zoo� <br /> ioios ivcn A�.nu. sc For Building Department Use <br /> e�.�.�a, xa <br /> ApplicantName: e:a�c Johnson, D.V.H. <br /> Applicanf Address: ioios isn, a.•n�. se, e�.�aec, vr. <br /> AppliwntPhone: �Zs-3�s-o�oo . <br /> Project Description �I New Building ❑Addi�ion ❑Afleralion [_�Change of Use <br /> ��Prescdptive �]Componenl Performance ❑Seattle EnvSid <br /> Compliance Option (See Decision Plowchart(over)for qualificalions) �Sys�ems Analysis <br /> Space Heat Type (�Eleciric resistance U All other (see over for defnitions) <br /> Total Glazing Area Electronic version: lhese values are automalically taken from ENV-UA-1. <br /> Glazing Area Calculation (rough opening) Gross Ex�erior <br /> Note:Below grade walls may be included in Ihe (�ertical&overhd) divided by Wall Area �imes 100 equals Yo Glazing <br /> Gross E�1erior Wall Area if t�ey are insulatnd l0 11 .5� <br /> the�eve�required mropaque wa��s. 28 B . B - Zb O B.Z X ��0 = <br /> � Yes Check here il using this option and il project meets all requiremenis br the Concrete/Masonry <br /> Conerete/Masonry Ortion Option See Decision Flowchart(over)for quatifwtions. Emer requirements for each qualrtying <br /> � �� assembly below. <br /> � yes Check here if using semi-heated path and il pro�ect meets all requirements lor semi-heated <br /> Semi-Heated Path /, spares as deGned in section 1310. ReQuires other fuel heauna and quahtymg thermastat Only <br /> V �� wall insulation requirement is reducetl(2006 change). Only available in prescnptive path. <br /> Envelope Requfrements(enter values as applicable) Opaque ConcretelMasonry Wall Requfrements <br /> Wall Maximum U-faclor is 0.15(R5.7 con�inuous ins) <br /> Minimum Insulafion R-values CMU block walls wilh insulated cores wmply <br /> Roofs Over Atlic 30.0 If project qualifies for Concrete/Masonry Oplion,list walls <br /> wilh HC>_9.0 Blulfl�°F below(olher walls must meel <br /> All Other Rools 21.0 Opaque Wall requiremenis). Use descriptions and values <br /> Opaque Walls' 19.0 from Table 10-9 in Ihe Code. <br /> Below Grade Walls Wall Description U-factor <br /> Ploors Over Unconditioned Space (including insulation R-value&posilion) <br /> Slabs-on�Grade 10.0 <br /> Radiant Floors <br /> h1azinwm U-/acfors <br /> Opaque Doors 0.060 <br /> Vertical Glazing 0.550 <br /> Overhead Glazing 0.700 <br /> Maximum SHGC(or SC) <br /> VerticallOverhead Glazing 0.450 <br /> 1.Assemblies with metal(raminc�must comply with overall U-factors <br /> Notes: <br /> ,��� <br />