My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2802 VICTOR PL 2020-06-03
>
Address Records
>
VICTOR PL
>
2802
>
2802 VICTOR PL 2020-06-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2020 11:02:00 AM
Creation date
6/3/2020 10:58:47 AM
Metadata
Fields
Template:
Address Document
Street Name
VICTOR PL
Street Number
2802
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2/10/2020 Page 17;3 <br /> City of Everett <br /> 11:59:22AM <br /> INSPECTION ACTIVITY REPORT --- <br /> Permit No. C1510-001 Site Address 2802 VICTOR PL <br /> Applied 10/1/2015 Applicant Lot <br /> Approved 12/15/2015 Owner DIAZ WALTER/BAUTISTANANCY Block <br /> Issued 12/21/2015 Contractor OWNER Tract <br /> Parent Permit No. D1512-004 Description NEW SFR <br /> Notes MUST MEET CONDITIONS LISTED IN REVII15-012. <br /> FRONT PORCH STEPS TO BE SAME WIDTH AS PORCH. <br /> SUB-PROJECT NCB 14-022. <br /> Scheduled Completed True Inspector Result Remarks Inspector's Comments <br /> 7/1/2016 7/1/2016 Permit Extension TAH Approval EXTENSION <br /> 9/1/2016 9/1/2016 Footing DWF Approval See notes Returned 3:03 PM <br /> Footings,as per plans,OK for concrete <br /> 9/22/2016 9/22/2016 Foundation DWF Corr Reqd See notes Foundation walls <br /> Partial approval <br /> Contractor needs to install one STHD10 at <br /> retaining wall-west side of house as per <br /> plans. <br /> Also-need to inspect for foundation/fotting <br /> „toe". <br /> Do not cover until east end of house <br /> inspected. <br /> 9/27/2016 12/12/2018 Footing DWF Unable to inspect, Footing correction-east end only. <br /> see notes Already covered. <br /> Footing(foundation wall needs a minimum <br /> of 2"toe on each side of wall.) <br /> 12/23/2016 12/23/2016 PlbgGrWork DXW Corr Reqd Uncover 3"ABS to <br /> see pipe <br /> 12/27/2016 12/27/2016 PlbgGrWork DLW Approval See notes Sanitary groundwork OK as noted: <br /> Back water valves(2)must be accessible or <br /> install risers. <br /> 6/8/2017 6/8/2017 StructSlab DWF Approval As noted #4 rebar 24"on center as per plans. <br /> 2"rigid foam R-10 installed. <br /> Contractor to set rebar on dobe blocks <br /> elevate to center of slab. <br /> 10/17/2017 10/17/2017 Bldg Other DWF Corr Reqd No access 12:04pm <br /> 11/2/2017 11/2/2017 Bldg Other DWF Con Reqd No access to <br /> plans/permit in site <br /> 1:08pm <br /> 11/3/2017 11/3/2017 Framing DWF Con Reqd Not ready from <br /> framing <br /> 11/8/2017 11/8/2017 ShearNailing DWF Con Reqd Nail sill plate with galvanized nails. <br /> Install CS16 brackets at 4 locations front <br /> entrance area. <br /> Missing STHD10 bracket <br /> foundation to wall west side and 2 CS16 <br /> brackets <br /> 11/14/2017 11/14/2017 BLDG EXTERIOR DWF PARTIAL APPR West wall need engineering/architectural <br /> SHEAR design plans for seismic brackets <br /> STH1O-CS16 <br /> Garage door opening. <br /> 4/11/2018 4/11/2018 GAS 01-ROUGH IN SDP APPROVAL See notes 1.Natural gas tested at 15 PSI-OK for <br /> service. <br /> 2.Refer pipe tested at 450#-OK for <br /> service.Location of outside unit is OK. <br /> 4/11/2018 4/11/2018 MECH 04-ROUGH SDP APPROVAL As noted Heat ducts under the toe kick of cabinets <br /> IN must be ducted to the outside of the cabinet <br /> at final. <br /> INSP12 C Ys TEM S <br />
The URL can be used to link to this page
Your browser does not support the video tag.