Laserfiche WebLink
2/10/2020 Page 1 <br /> 11:31; 7AM City of Everett • <br /> / <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. E1803-071 Site Address 2802 VICTOR PL <br /> Applied 3/12/2018 Applicant Lot <br /> Approved 3/12/2018 Owner DIAZ WALTER/BAUTISTANANCY Block <br /> Issued 3/12/2018 Contractor OWNER Tract <br /> Parent Permit No. C1510-001 Description WIRE NEW SFR <br /> Notes MUST MEET CONDITIONS LISTED IN REVII15-012. <br /> FRONT PORCH STEPS TO BE SAME WIDTH AS PORCH. <br /> SUB-PROJECT NCB 14-022. <br /> Scheduled Completed Tyne Insuector Result Remarks Inspector's Comments <br /> 3/16/2018 3/16/2018 ELEC 08-OTHER SKB CORRECTION No access 9:13am <br /> 3/20/2018 3/20/2018 ELEC 08-OTHER SKB CORRECTION Not ready <br /> Make up all ground prior to inspection. <br /> Properly secure Nm cable. <br /> Add receptacles as needed for wall and <br /> counter spacing. <br /> Install arc fault and over-current devices. <br /> Install concrete encased electrode. <br /> 3/29/2018 3/29/2018 ELEC 03-ROUGH SKB CORRECTION Not ready. <br /> IN Make up ground prior to inspection. <br /> 4/10/2018 4/11/2018 ELEC 03-ROUGH SKB CORRECTION Not ready <br /> IN Properly secure/support NM cables. <br /> Install all junction box covers on can lights. <br /> Add receptacles to meet NEC210.52. <br /> Make up all grounds. <br /> Replace damaged NM cables. <br /> Install a receptacle within 6'of sink. <br /> Individual conductors can not be outside of <br /> can light junction box. <br /> Living room can not be on small applicance <br /> circuit. <br /> 4/16/2018 4/16/2018 ELEC 08-OTHER SKB OTHER Provide 2nd branch circuit to kitchen <br /> counter. <br /> Install receptacles per NEC 210.52. <br /> Add a receptacle within 3'of all sinks. <br /> Label all circuits in panel. <br /> Properly secure and support all NM cables. <br /> All conductors have to be inside the <br /> J-boxes. <br /> Cannot run all of the home runs in the same <br /> hole-no bundling. <br /> Complete all previous corrections. <br /> Not ready <br /> If correction on enxt inspection,a trip fee <br /> may be assessed. <br /> 4/23/2018 4/23/2018 ELEC 03-ROUGH SKB CORRECTION Please complete all previous correction and <br /> IN wiring. <br /> Please pay trip fee prior to next inspectin. <br /> Trip fee assessed. <br /> 8/29/2018 8/29/2018 ELEC 05-SERVICE SKB APPROVAL eTRAKiT Inspection 8/28/2018 1:03 PM <br /> Request Please call Walter for access <br /> Contact Name:Walter Diaz <br /> Site Address:2802 VICTOR PL <br /> Phone:4253510924 <br /> e-Mail:proficientelectricllc@gmail.com <br /> Provide access to the UFER ground <br /> connection-check at final. <br /> INSP12 Chi lli/s YS TEM S <br />