My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2915 17TH ST 2020-06-03
>
Address Records
>
17TH ST
>
2915
>
2915 17TH ST 2020-06-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2020 11:54:35 AM
Creation date
6/3/2020 11:53:43 AM
Metadata
Fields
Template:
Address Document
Street Name
17TH ST
Street Number
2915
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2/25/2020 Page <br /> City of Everett <br /> 11:39:38AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. E1805-040 Site Address 2915 17TH ST <br /> Applied 5/7/2018 Applicant OWNER Lot <br /> Approved 5/7/2018 Owner SHAPIRO RACHEL Block <br /> Issued 5/7/2018 Contractor OWNER Tract <br /> Parent Permit No. C1804-006 Description ELECTRICAL PHASE I RELOCATE METER BASE <br /> Notes <br /> Scheduled Completed Tvne Inspector Result Remarks Inspector's Comments <br /> 5/10/2018 5/10/2018 ELEC 05-SERVICE SKB CORRECTION Properly install the mast using listed means. <br /> Properly secure the mast(framing and <br /> strapping) <br /> Install main bonding jumper. <br /> Bond all metal piping systems,waste,etc. <br /> Provide proper clearance over alley for <br /> overhead conductors. <br /> 6/5/2018 6/5/2018 ELEC 05-SERVICE SKB CORRECTION Install the main bonding screw etc from <br /> previous inspection. <br /> 6/22/2018 6/22/2018 ELEC 08-OTHER SKB CORRECTION eTRAKiT Inspection Install anode compliant service that meets <br /> Request code as shown. <br /> 6/20/2018 12:23 PM Anthony Shapiro <br /> :We are on site Friday 6/22 AM. would like <br /> to meet at 9:00-10:00 if at all possible, <br /> Thanks <br /> Contact Name:Anthony Shapiro <br /> Site Address:2915 17TH ST <br /> Phone:4257785400 <br /> e-Mail:tonys@adshapiro.com <br /> 7/2/2018 7/2/2018 ELEC 05-SERVICE SKB CORRECTION Correction not completed.Install a service <br /> rated Meyers hub if you are going to use <br /> one and bond it.Compression board on <br /> wrong side of mast?Per email. <br /> 7/12/2018 7/12/2018 ELEC 05-SERVICE PXN CORRECTION No access,gate <br /> locked <br /> 7/13/2018 7/13/2018 ELEC 05-SERVICE PXN CORRECTION Put wood blocking beteen PVC pipe and <br /> wall under straps. <br /> Put metal over gap in studs at PVC pipes to <br /> protect from sheet rock screws. <br /> Only 1/2"of jeckset into panel and boxes. <br /> Wire to be stapled within 6"of boxes. <br /> Show where the ground wires are attached. <br /> 7/17/2018 7/17/2018 ELEC 05-SERVICE PXN APPROVAL Ok service <br /> 11/15/2018 11/15/2018 ELEC 03-ROUGH TRA CORRECTION Accurate panel schedule required for <br /> IN inspection. <br /> Note:3 wire cable(14-3WG)required for <br /> smoke detectors. <br /> Smoke detectors must be attached to outlet <br /> box. <br /> 11/20/2018 11/20/2018 ELEC 03-ROUGH TRA PARTIAL APPR OK rough electrical. <br /> IN 1.Dishwasher&disposal may not be on <br /> kitchen plug circuit. <br /> Put on separate circuit(20a or 2 15a) <br /> AFCI/GFCI. <br /> 2.Microwave requires separate circuit <br /> AFCI. <br /> Will check at final. <br /> 11/20/2018 12/13/2018 ELEC 03-ROUGH TRA <br /> IN <br /> 6/21/2019 6/21/2019 ADMIN USE KLC APPROVAL <br /> ONLY** <br /> 6/21/2019 6/21/2019 ELEC 09-FINAL TRA APPROVAL �r <br /> INSP12 CRWSSYSTEMS <br />
The URL can be used to link to this page
Your browser does not support the video tag.