Laserfiche WebLink
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 A <br /> LEGEND: <br /> / <br /> / • CLEANOUT <br /> / : ■ CB TYPE 1/INLET <br /> � o <br /> E • CB TYPE 1L <br /> / v1 <br /> / w e CB TYPE 2 <br /> n / N <br /> 8 /I\ <br /> AT LOCATIONS et) <br /> 41 so STORM LINE <br /> / IDENTIFIED BY CTPM LJ <br /> N i� '^ uo UNDERDRAIN <br /> til / MATCH EXISTING GRADES \\*iCLEAR, GRADE, HYDROSEED <br /> 'I /--'' 004 /; CONSTRUCTION NOTES: <br /> / 0 REMOVE EXIST CONCRETE TRENCH DRAIN. SIZE <br /> III / GRADE EXISTING NATIVE MATERIAL VARIES T OR 11" MADE. SEE NOTE 12 ON SHEET <br /> HYDROSEED ALL DISTURBED AAREAS. CONNECT TO'EXISTIN SDN01. <br /> / TO DRAIN TO CONCRETE G <br /> Ela„PIPE 0 CONNECT TRENCH DRAIN TO NEW CATCH BASIN, <br /> / .. SEE DETAIL 13, SHEET SDD03. <br /> E / ® CONSTRUCT NEW 8" 0 REMOVE EXIST CATCH BASIN. <br /> SDD03 DIAMETER UNDERDRAIN PIPE <br /> el / . O RECONSTRUCT WATERLINE AS NEEDED TO AVOID <br /> / An CONSTRUCT NEW CEMENT CONFLICT WITH STORM DRAIN. <br /> / SDD03 CONCRETE DRAINAGE SWALE <br /> O 0 COORDINATE WITH PUGET SOUND ENERGY TO <br /> T- <br /> / i�' C � RELOCATE GAS TO AVOID CONFLICT WITH STORM <br /> CONSTRUCT-NEIN CLEANOUT ASSEMBLY. DRAIN. <br /> CL <br /> INSTALL SALVAGED CASTING COVER. ' <br /> MATCH EXISTING GRADES <br /> J, / 0 VERIFY ELEVATION AND LOCATION OF POWER AND <br /> / . ._ COMMUNICATIONS CONDUIT CROSSINGS WITH STORM. <br /> RELOCATE CONDUIT AS NECESSARY. <br /> / 0 CLEANOUT, SEE DETAIL 20, SHEET SDD04. <br /> / GENERAL NOTES: <br /> / i ,. <br /> CONTRACTOR SHALL VERIFY GRADES FOR <br /> DRAINAGE BEFORE CONSTRUCTION BEGINS. <br /> S11 <br /> 10,,,,/ AT LOCATIONS 2. CONTRACTOR SHALL VERIFY LOCATION OF ALL <br /> / IDENTIFIED BY CTPM bo� j% _ <br /> UTILITIES AND DOCUMENT PRIOR TO BEGINNING <br /> . � � CONSTRUCTION. <br /> 6 II <br /> If/ <br /> ��� � <br /> E / // . .-- -- --... .. .. . ..,--- 5010 SDO8 <br /> / <br /> //, 5009 <br /> T)',...... <br /> El SD04 SDO5 SDO6 5007 <br /> O /i,. 'V _ <br /> 61 <br /> o2 el <br /> / <br /> PHASE 3 KEY PLAN <br /> tra 4, ..--' .. •_,, ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,„ 1,,,e,,,,,,,t,,,,,,,,,,,,,,,,,,,,,,,,,,,, <br /> ' <br /> ['' .... . ... -- ,-- <br /> s= <br /> S- <br /> 0 10 20 40 <br /> 1 inch=20 ft.HORZ <br /> 0 2.5 5 10 <br /> t t1 inch=5 ft VERT <br /> DRAWN BY DESIGNED BY 1'LE/J� MCOB PAVEMENT RENOVATION AND REPLACEMENT SHEET <br /> T TLC KJH �y2%a uas,ZGykpff o� �0 0 A <br /> Eo _ .CHECKED BY APPROVED BY e,,< ,� tc, commumtyt�nsit/ 7000/7100 HARDESON ROAD, EVERETT, WASHINGTON <br /> $ LAW RJL ,1 , • ae STORM DRAINAGE SD09 <br /> DATE ,•.. �A �/ mlls>, <br /> 2/14/18 KJH LAW RJL ADDENDUM 1 Pf� ` teat sth Avenue,Suite teoo PLAN <br /> o g 1/25/2018 Aect is �o��Q seaai�wn extol 7100 Hardeson Road <br /> SSIONIL Eg6 206.622.5822 Everett.Washington 98203 <br /> NO, DATE BY CHD APPR. REVISION J 0 B No. 1600557 2/21/18 www.kpff.com ( ) PHASE 3 <br /> (425)348-2312 Fax 425 438-6141 78 OF 121 <br />