My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7000 HARDESON RD Geotech Report 2022-10-25
>
Address Records
>
HARDESON RD
>
7000
>
Geotech Report
>
7000 HARDESON RD Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:31:51 PM
Creation date
6/5/2020 2:03:52 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7000
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED SOIL CLASSIFICATION SYSTEM <br /> MAJORGROUP GROUP NAME <br /> DIVISIONS <br /> SYMBOL <br /> GRAVEL GW WELL-GRADED GRAVEL,FINE TO COARSE GRAVEL <br /> COARSE- CLEAN GRAVEL <br /> GP POORLY-GRADED GRAVEL <br /> 'GRAINED MORE THAN 50%OF <br /> COARSE FRACTION GRAVEL GM SILTY GRAVEL <br /> SOILS RETAINED ON NO.4 WITH FINES <br /> SIEVE GC CLAYEY GRAVEL <br /> SAND CLEAN SAND SW WELL-GRADED SAND,FINE TO COARSE SAND <br /> MORE THAN 50% SP POORLY-GRADED SAND <br /> RETAINED ON <br /> NO.200 SIEVE MORE THAN 50%OF <br /> COARSE FRACTION SAND SM SILTY SAND <br /> PASSES NO.4 SIEVE WITH FINES <br /> SC CLAYEY SAND <br /> FINE- SILT AND CLAY INORGANIC ML SILT <br /> GRAINED CL CLAY <br /> SOILS LIQUID LIMIT <br /> LESS THAN 50% ORGANIC OL ORGANIC SILT,ORGANIC CLAY <br /> SILT AND CLAY INORGANIC MH SILT OF HIGH PLASTICITY,ELASTIC SILT <br /> MORE THAN 50% CH CLAY OF HIGH PLASTICITY,FAT CLAY <br /> PASSES NO.200 SIEVE LIQUID LIMIT <br /> 50%OR MORE ORGANIC OH ORGANIC CLAY,ORGANIC SILT <br /> HIGHLY ORGANIC SOILS PT PEAT <br /> NOTES: SOIL MOISTURE MODIFIERS <br /> * 1) Field classification is based on Dry-Absence of moisture,dusty,dry <br /> visual examination of soil in general to the touch <br /> accordance with ASTM D 2488-93. <br /> * 2) Soil classification using laboratory Moist-Damp, but no visible water <br /> tests is based on ASTM D 2487-93. Wet-Visible free water or saturated, <br /> 3) Descriptions of soil density or usually soil is obtained from <br /> consistency are based on below water table <br /> interpretation of blowcount data, <br /> visual appearance,of soils,and/or <br /> test data. <br /> *Modifications have been applied to ASTM KEY TO BORING LOG SYMBOLS <br /> methods to describe sit and clay content. <br /> VGround water level <br /> Nss=NM*CE*CB*CR*Cs • Blows required to drive <br /> NM=blows/foot,measured in field sample 12 in. using SPT(converted to N6,) <br /> CE=ER,,,/60,convert measured hammer energy <br /> to 60%for comparison with design charts. MC(U)=%Moisture= ,(weight of water) <br /> CB=adjusts borehole diameter (Weight of dry soil) <br /> CR=rod length,adjusts for energy loss in rods DD=Dry Density <br /> Cs=Sample liner=1.0 <br /> — Letter symbol for soil type <br /> SM Contact between soil strata <br /> — — (Dashed line indicates approximate <br /> ML contact between soils) <br /> — Letter symbol for soil type <br /> NOTE:The stratification lines represent the approximate boundaries between soil types and the transition may be gradual <br /> PM: BAG Figure 3 <br /> ROBINSONFebruary 2018 <br /> NOBLE <br /> 3224-002A KPFF: Community Transit Merrill Creek Operating Base <br />
The URL can be used to link to this page
Your browser does not support the video tag.