Laserfiche WebLink
Vertical Fenestration s, rget Area Adjustment Cak lations <br /> Project Title: Terra Power Tenant Improvement Phase I Date 07/18/2018 <br /> If vertical fenestration area exceeds maximum allowed per Section C402.4.1,then Target Area Adjustment of all applicable envelope elements is <br /> required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information <br /> shown in this worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration NW=Net above grade wall(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+ DR <br /> AG=Above-grade <br /> Proposed Areas Vertical Fenestration Net Above Grade Wall Opaque Door <br /> Project Areas-> VF= 2951.0 NW= 36109.0 DR= 2634.0 <br /> Existing Non-project Areas-> VF= NW= <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert. Fen.Area <br /> 41694.0 X 30.0% - 100 = 12508.2 <br /> Total Vertical / Delta Vertical Excess Vertical <br /> Fenestration Maximum Target I�/ Fenestration 0 Fenestration <br /> 2951.0 - 12508.2 = -9557.2 greater = <br /> -9557.2 <br /> / Multiplier applied to all <br /> Project Vertical Excess Vertical / Target Vertical Total Vertical Proposed Vertical <br /> Fenestration Fenestration Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> --- calculate Target Vertical <br /> 2951.0 - = 2951.0 2951.0 = 1.00 Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all <br /> 36109:0 + = 36109.0 . 36109.0 = 1.00 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> Tar et Areas - UA calculate Target Above- <br /> Target Grade Wall Area <br /> Commercial <br /> Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> Non-metal frame X <br /> Metal frame,fixed 2870.0 X 1.00 = 2870.0 <br /> Metal frame,operable X = <br /> Metal frame,entrance door 81.0 X 1.00 = 81.0 <br /> Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel Frame X = target areas on ENV-UA <br /> Metal Building X = <br /> Wood/Other frame X = <br /> Mass 36109.0 X 1.00 = 36109.0 <br /> Mass Transfer Deck X = <br /> Group R Mass X = <br /> Sum of target above-grade <br /> Sum of Proposed 39060.0 Sum of Target 39060.0 wall and vertical <br /> fenestration areas are <br /> Target Areas - SHGC x A calculated to equal the <br /> sum of proposed <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 X = <br /> 0.2_<PF<0.5 X = <br /> PF>_0.5 X = SHGC target areas in <br /> shaded boxes are applied <br /> North Vertical Fenestration to target areas on ENV- <br /> PF<0.2 X = SHGC <br /> 0.2<_PF<0.5 , X <br /> PF L. X = <br />