A <br /> Ms. Nadia Azarova <br /> Craft Architects <br /> Plan Check Number: B1810-016, First Review <br /> November 30, 2018 <br /> 15.The structural calculations state that the lateral force resisting system is a steel ordinary <br /> concentrically-braced frame. However, the drawings specify moment frame connections <br /> between the beams and columns at Grids B/4, C/1, and C/4 on Plans 1/51.1 and 2/S1.1. <br /> The connections are not provided to exclusively facilitate cantilever support of the stairway <br /> framing, and lateral bracing is not provided at locations specifying moment connections. <br /> The FEM in the structural calculations indicates two-way bracing at each level for the full <br /> height of the structure on Grids B/2-4, 2/B-C, and 4/B-C. The FEM does not include <br /> moment frame connections. Furthermore, the use of moment frames is not permitted in <br /> Seismic Design Category D per ASCE 7-10 Table 12.2-1 Item CA, and it does not qualify for <br /> use per Section 12.2.5.6.1. The structural drawings shall be revised for consistency with <br /> the structural calculations. See IBC Sections 1603.1, 1604.4, and 1613.1. <br /> 16.The columns included in the lateral frames shall satisfy the requirements of AISC 341-10 <br /> Section D1.4a in addition to other load requirements. Calculations substantiating the design <br /> of the columns shall be submitted for review. See IBC Section 2205.2.1.2. <br /> 17. Structural calculations substantiating the design of the diaphragm bracing and connections <br /> are not included in the calculations package and shall be submitted for review. The angles <br /> are connected to the connection plates though one leg. The design shall consider eccentric <br /> loading in the braces and the connections. The brace-to-connection plate design shall <br /> include shear lag. The connection plate-to-structural framing forces shall be determined <br /> using a generally-accepted method (e.g., Uniform Force Method, etc.). See IBC Sections <br /> 1604.1 and 2205.1, and AISC 360-10 Sections D3, E5, F10, and H1, and Chapter J. <br /> 18. Structural calculations substantiating the design of the tension braces and their connections <br /> are not included in the calculations package and shall be submitted for review. The design <br /> load for the brace connections shall satisfy AISC 341-10 Section 6a. The connection plate- <br /> to-structural framing forces shall be determined using a generally-accepted method (e.g., <br /> Uniform Force Method, etc.). The base plates connect to the faces of the HSS columns and <br /> shall verify the strength of the column wall per AISC 360-10 Section K1 and Table K1.2. <br /> See IBC Sections 2205.1 and 2205.2.1.2, and AISC 360-10 Chapters D and 3. <br /> 19.The design of the column bases shall satisfy the requirements of AISC 341-10 Section D2.6. <br /> Calculations substantiating the design shall be submitted for review. See IBC Sections <br /> 1604.2, 1613.1, and 2205.2.1.2. The following comments shall be addressed: <br /> a. Calculations substantiating the design of the column bases for axial and shear loading <br /> shall be designed per AISC 341-10 Sections D2.6a and D2.6b. <br /> b. The anchorage of columns to the foundations shall be performed per ACI 318-14 <br /> Chapter 17. See AISC 341-10 Section D2.6; note that this section references ACI 318 <br /> Appendix D for the design of concrete anchors, which not occurs in Chapter 17. The <br /> anchors shall satisfy the requirements of ACI 318-14 Sections 17.2.3.4.2 and 17.2.3.5.2. <br /> The load combinations of ASCE 7-10 Section 12.4.2.3 and 12.4.3.2, including the vertical <br /> seismic load effect per Section 12.4.2.2, shall apply. <br /> c. Continuing with the previous comment, the concrete footings in Detail 1/S1.2 do not <br /> have sufficient weight to resist the uplift forces from the braced frames. The <br /> connections between the footings and the slab-on-grade shall similarly satisfy the <br /> requirements of ACI 318-14 Chapter 17. <br /> O 3200 Cedar Street �:/ 425.257.8800 O everettpw@everettwa.gov <br /> Everett,WA 98201 425.257.8882 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.