My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3315 SEAWAY BLVD 2020-06-05
>
Address Records
>
SEAWAY BLVD
>
3315
>
3315 SEAWAY BLVD 2020-06-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2020 3:23:08 PM
Creation date
6/5/2020 3:18:13 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3315
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
195
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Summary ENV-SUM <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Info Project Title: Terra Power Tenant Improvement Date 07/18/2018 <br /> Applicant Info. Company Name: Craft Architects For Building Department Use <br /> Provide contact Company Address: 2505 Third Avenue,Suite 324,Seattle WA 98121 <br /> information for <br /> individual who can Applicant Name: Nadezhda Azarova <br /> respond to inquiries Applicant about information A pp Phone: 206-720-7001 <br /> provided. Applicant Email: nadia@craftarchitects.com <br /> Project Description ❑ New Building El Addition ❑Q Alteration ❑ No Envelope Scope <br /> Envelope Project Scope El All Commercial El Group R-Commercial ❑ Mixed Use-Commercial+Group R <br /> Select all that apply. <br /> El Semi-heated ❑ Refrigerated Cooler El Refrigerated Freezer ❑ Equipment Building <br /> Envelope Description Addition of insulation to the interior side of perimeter walls of the existing uninsulated <br /> Provide brief description of the project and warehouse shell building as the phase I Tenant Improvement for the research company <br /> relevant supporting documentation. utilizing the space as a mixture of large open and enclosed areas that either require or not <br /> require conditioning. It deems more appropriate to insulate the whole building rather than <br /> If project includes multiple Target Insulation to attempt to compartmentalize and condition multiple separate spaces. <br /> Allowance areas,and/or is demonstrating <br /> compliance as an Addition+Existing, <br /> Alteration+Existing,or <br /> Addition+Alteration +Existing project, <br /> provide a brief summary of the approach to <br /> whole building compliance. <br /> Air Barrier Testing ❑Air barrier testing per Section C402.5.1.2 included in project scope <br /> Air barrier testing is required for all new <br /> construction projects. Testing criteria is 0.40 ❑Additional Efficiency Package Option-C406.9 Reduced Air Infiltration <br /> cfm/ft2 under test pressure of 0.3 inch w.g. <br /> To comply with C406.9,demonstrate that ❑Testing not required. Explanation: <br /> measured air leakage of building envelope <br /> Compliance Documentation Scope and Method <br /> Scope of This Calculation ❑ New Building ❑ Addition 0 Alteration ❑ No Envelope Scope <br /> Target Insulation Allowance ® Fully Conditioned-Commercial,Group R,Mixed Use <br /> Sets the title and calculations in the <br /> compliance forms.Selection required 0 Semi-heated 0 Refrigerated Cooler 0 Refrigerated Freezer <br /> to enable forms. If project includes more than one Target Insulation Allowance area,and/or if project includes <br /> addition and alteration areas complying independently,for each area complete an ENV-SUM form <br /> Rows 16-46 and either an ENV-PRESCRIPTIVE form,or ENV-UA+ENV-SHGC forms if <br /> demonstrating compliance via component performance. <br /> Envelope Compliance Path <br /> 0 Prescriptive ® Component Performance <br /> Selection required to enable forms. <br /> Component Performance Change of Occupancy(C503.2)/Conditioning(C505)-10%higher UA allowed <br /> Calculation Adjustments ❑ Additional Efficiency Package Option-C406.8 Enhanced Envelope-15%lower UA required <br /> Additions 0 Addition stand alone 0 Addition+Existing <br /> Addition stand alone-Complete Vertical Fenestration and Skylight Area Calculation.Enter total existing-to-remain wall,roof,vertical <br /> fenestration and skylight areas as EXISTING.Enter total addition envelope assembly areas as NEW.If resulting total building WWR exceeds <br /> 30%and/or SSR exceeds 5%,refer to C502.2.I and C502.2.2 for prescriptive compliance alternatives.If complying via component performance, <br /> complete ENV-UA per instructions for addition stand alone projects. <br /> Addition+existing-Complete ENV-UA per instructions for addtion+existing projects. <br /> Alterations- El❑ Replacement windows only,or resulting <br /> Li Total building WWR increased by alteration <br /> total building WWR s original WWR <br /> Fenestration and Skylight <br /> ❑ Replacement skylights only,or resulting ❑ Total building SRR increased by alteration <br /> total building SRR 5 original SRR <br /> WWR and SRR not increased-Vertical Fenestration and Skylight Area Calculation not required. <br /> WWR and/or SRR increased-Complete Vertical Fenestration and Skylight Area Calculation.Enter total existing-to-remain wall,roof,vertical <br /> fenestration and skylight areas as EXISTING.Enter total altered envelope assembly areas as NEW.If resulting total building WWR exceeds 30% <br /> and/or SSR exceeds 5%,refer to C503.3.2 and C503.3.3 for prescriptive compliance alternatives.If complying via component performance, <br /> complete ENV-UA per instructions for alteration+existing projects. <br />
The URL can be used to link to this page
Your browser does not support the video tag.