Laserfiche WebLink
4 Jan 2019 01:06:40-Summary Design Criteria.sm <br /> NKH PROJECT SUMMARY & DESIGN CRITERIA <br /> ENGINEER NG <br /> PROJECT NAME: Everett Carport DESIGNER: NKH <br /> Project Summary <br /> Llateral design only for a carport cover for the residence located at 5409 S 2nd Ave in Everett, WA. <br /> The project will be designed according to the 2015 Seattle Building Code (SBC). <br /> Reference Codes <br /> International Building Code, 2015 Edition (IBC) <br /> ASCE/SEI 7-10 Minimum Design Loads for Buildings & Other Structures (ASCE) <br /> ACI 318-14 Building Code Requirements for Strctural Concrete (ACI) <br /> ANSI/AWC NDS-2015 National Design Specification for Wood Construction (NDS) <br /> Material Properties <br /> Soil <br /> Soil Bearing Pressure (min per IBC) pbrg:=1500 psf <br /> Concrete <br /> Compressive Strength f'c :=3000 psi <br /> Frost Depth (Bottom of Footing) FD :=18 in <br /> Density, Normal Weight Yconc ==150 •pcf <br /> Reinforcing Steel, ASTM A615 Yr :=60 ksi <br /> Steel <br /> Modulus of elasticity Eo :=29000 ksi <br /> Plates, ASTM A36, Yield Strength y1 :=36 ksi <br /> Structural Pipe, ASTM A53 Gr. B Fye :=35 ksi <br /> Hollow Structural Sections, y3 :=46 ksi <br /> Tube ASTM A500 Gr. B <br /> Anchor Rods/Bolts, ASTM A307 Env :=24 ks nt :=4 5 ksi <br /> Wood <br /> Beams, Headers, & Joists DF-L #1 6x & Larger, UNO <br /> DF-L #2 All Other, UNO <br />