My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
>
Address Records
>
EVERGREEN WAY
>
8417
>
PANDA EXPRESS
>
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:24:40 AM
Creation date
6/15/2020 2:50:39 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8417
Tenant Name
PANDA EXPRESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Brad Marucha <br /> MCO and Associates <br /> Plan Check Number: B1908-057, First Building Review <br /> September 10, 2019 <br /> Geotechnical <br /> 1. The submittal documents for Permit No. B1805-010 include a geotechnical report prepared by <br /> Terracon, dated February 1, 2018. Section 4.6 states that"the proposed site development does <br /> not indicate for a retaining wall to be built", but appears to provide criteria for the design of site <br /> retaining walls. The geotechnical engineer shall provide a letter verifying that the design <br /> criteria provide in Section 4.6 is appropriate for the design of the proposed site retaining walls. <br /> Additional recommendations for the design of the walls shall be provided as needed. See IBC <br /> Sections 1803.2 and 1803.6. <br /> 2. Continuing with the previous comment, the retaining walls are located near existing buildings <br /> and parking surfaces that may place lateral surcharge pressures on the walls. Note that the <br /> wall section on page 14 schematically shows a surcharge load but does not specify values or a <br /> influence distance behind the wall. The geotechnical engineer shall provide additional <br /> recommendations for surcharge loads as needed. See IBC Sections 1610.1, 1803.2, and <br /> 1803.6. <br /> Structural <br /> 1. Detail 5/SF1.1 is included on Sheet SF1.1. This sheet was previously approved for construction <br /> under Permit No. B1805-010, and includes other details and information that is not part of the <br /> current permit. Detail 5 shall be provided on a new sheet, or the other information shall be <br /> crossed out and marked as"Not in Permit". See IBC Section 107.2.1. <br /> 2. The construction drawings do not include a site plan showing the location for the proposed <br /> concrete retaining walls. It is presumed that the walls will replace the CMU retaining walls <br /> along the north and south property lines as shown in Section A-A/C-200 of Permit No PW1805- <br /> 015. Revised site plans showing the proposed wall locations shall be submitted for review. <br /> Additional sheets in Permit No PW1805-015 shall be revised as needed where affected by the <br /> proposed change to the project. See IBC Section 107.2.1. <br /> 3. The retaining wall section in Detail 5/SF1.1 is oriented with a heel into the retained soil. <br /> However, Section A-A/C-200 shows the wall along the north property line with a toe; the wall <br /> does not include a heel projecting into the retained soils to provide rotational restraint. <br /> Additional details shall be provided to represent all wall conditions proposed for the project site. <br /> See IBC Section 107.2.1 and 1603.1. <br /> 4. The submittal documents do not include structural calculations. Calculations substantiating the <br /> design of the site retaining walls shall be submitted for review. The calculations shall represent <br /> all wall conditions proposed for the project site. Walls retaining more than 6 feet of soil shall <br /> include a seismic surcharge pressure per IBC 1803.5.12 Item 1. See IBC Sections 1604.1, <br /> 1604.4, 1610.1, 1605.1.1, and 1807.2. <br /> 5. Detail 5/SF1.1 includes a note specifying gravel and a perforated pipe for drainage. However, <br /> the pipe has been crossed out and a commented added that references an unidentified RFI. <br /> 0 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of .�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.