., <br /> Drew Martin <br /> From: Drew Martin <br /> Sent: Monday, September 23, 2019 1:09 PM <br /> To: 'Brad Marucha' <br /> Subject: RE: City of Everett Permit Services: 8417 Evergreen Way(B1908-057) - First Building <br /> Review <br /> Brad, <br /> I've performed a quick review of the submitted documents. We will need hardcopies of the drawings. Also,there <br /> appear to be some changes that were not in the original design,so this will need to be reviewed by both public works <br /> and planning. While I often review an electronic version,the other departments may require the hardcopy. I will <br /> forward and let them contact you as needed. <br /> Here are a few things that I'm seeing: <br /> • The changes affect the PW-drawing per the response to Comment 1. The updated drawing should be included <br /> to complete this review. In addition,the walls have been moved to this sheet. The sheet that included the site <br /> walls should be updated to removed the unused sections and details. <br /> • Sheet SW1.0 still states CMU walls in the sections. <br /> • The response to Comment 3 appears to indicate that the wall for the "opposite side" has simply been rotated <br /> 180-degrees. This may not be adequate. One notable issue is that the bottom reinforcement is the flexural <br /> reinforcement for Detail 4/SW1.0. The bottom reinforcement has not been provided with a lap, nor does the <br /> vertical bar hook provide a sufficient lap length with the bottom reinforcement. <br /> • The minimum soil cover for the wall in Detail 4/SW1.0 should be specified. <br /> • The response to Comment 4 states that updated calculations will be submitted. These do not appear included in <br /> the documents and shall be submitted in order to complete the review. <br /> • The extended wall in Detail 3/SW1.0 will have additional wind loading concurrent with soil loading. Note that if <br /> the wall is located near a walking surface, it must have a minimum height required for guards; a concurrent <br /> lateral live load will also be required. <br /> • Per the response to the geotechnical comments,the wall designs shall include concurrent live load surcharges as <br /> needed. <br /> • Partial Plan A/SW1.1 shows the north wall differently than the other two walls. The wall also appears open- <br /> ended;the extent is not clear. Review and revise the partial plan as needed to verify that all wall extents are <br /> correctly shown. <br /> Drew Martin, P.E.,S.E. <br /> Associate Engineer—Commercial Plans Examiner I Permit Services <br /> Lnoi <br /> 425.257.8813 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Hours: Monday—Friday 7:30am-12:OOpm and 1:OOpm-4:OOpm <br /> everettwa.gov I Facebook I Twitter <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> From: Brad Marucha <bradm@mcogc.com> <br /> Sent: Monday,September 23, 2019 11:43 AM <br /> To: Drew Martin<dmartin@everettwa.gov> <br /> Subject: RE: City of Everett Permit Services: 8417 Evergreen Way(B1908-057)- First Building Review <br />