' 2015 Washington State Energy Code Compliance Forms for Commercial,R2 and R3 over 3 stories and all R1
<br /> Mechanical Summary MECH-SUM
<br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017
<br /> Project Information Project Title: Panda Express Date 3/16/2018
<br /> Applicant Information. Provide contact information for individual who can respond to For Building Dept.Use
<br /> inquiries about compliance form information provided.
<br /> Company Name: CRM Architects&Planners Inc.
<br /> Company Address: 5921 Folsom Blvd.,Saramento,CA 95819
<br /> Applicant Name: Lupe Sandoval
<br /> Applicant Phone: (916)451-1500
<br /> Project Description ❑New Building ❑Building Addition LITenant Improvement ❑System Retrofit ❑No System Changes
<br /> Briefly describe mechanical systems in
<br /> the text box provided
<br /> ❑Total Bldg Performance(TBP)
<br /> This path includes all mandatory
<br /> provisions per C401.2 Option 2.
<br /> MECH-SUM,MECH-CHK,and 0407
<br /> Energy Analysis forms required.
<br /> ❑., Load calculation summary ❑ MECH-LOAD-CALC Form
<br /> Design Load Calculations Provide design load calculations for all mechanical systems and equipment serving the building heating,cooling or
<br /> ventilating needs.If a load calculation summary is provided with the permit documents that includes all applicable
<br /> compliance information then the MECH-LOAD-CALC form is not required.
<br /> Cl Mechanical Plans ❑ MECH-EQ Forms(TBD)
<br /> Mechanical Schedules Indicate location of equipment compliance information.If provided on plans then MECH-EQ forms are not required,
<br /> however,include on plans all applicable compliance information listed in MECH-EQ tables.
<br /> ❑ DOAS is required per C403.6 effective July 1,2017(office,retail,education,library and fire station occupancies)
<br /> All occupied,conditioned areas shall be served by a DOAS that delivers required ventilation air in a manner that does
<br /> not require space conditioning fan operation.Space conditioning fans cycled off when no heating or cooling is required. .
<br /> Dedicated Outdoor Air El Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS(C403.6,Exception 1)
<br /> System Requirements and ❑ Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS(C403.6,Exception
<br /> High Efficiency VAV ❑ DOAS included in project,although not required(occupancy not office,retail,education,library or fire station)
<br /> Alternate
<br /> ❑ DOAS related allowances included in project:
<br /> ❑ Prescriptive vertical fenestration maximum area allowance increased to 40%per C402.4.1.4 with 100%of
<br /> conditioned floor area in building served by DOAS.
<br /> ❑ Exception to air economizer per C403.3 Exception 1,include MECH-ECONO form.
<br /> ❑✓ Project includes HVAC air distribution systems that provide heating and/or cooling
<br /> If yes,provide a MECH-FANSYS-SUM form.
<br /> Fan Power ❑ For one or more systems,the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp.
<br /> If yes,provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold.
<br /> Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions.
<br /> ❑ Hydronic chilled water ❑ Water-loop heat pump ❑I No hydronic systems
<br /> HVAC Hydronic Systems •
<br /> ❑ Hydronic heating water ❑ Geothermal
<br /> ❑ C406.2 More efficient HVAC equipment and fan systems
<br /> Requires 90%of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9)or air-to-water heat
<br /> pumps and heat recovery chillers.All equipment listed in tables C403.2.3(1)-(7)must be 15%more efficient than
<br /> minimum requirements.All stand alone supply,return,and exhaust fans over 1hp must have FEQ>_71 and must be
<br /> C406 Additional Efficiency selected within 10%of maximum total or static pressure.
<br /> ❑ C406.6 Dedicated outdoor air system(DOAS)
<br /> Options Mechanical Requires 90%of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a
<br /> manner that does not require space conditioning fan operation.
<br /> ❑ C406.7 Reduced energy in service water heating
<br /> f Requires 90%of floor area be in occupancy types listed in 0406.7.1 and that 60%of annual hot water energy use be
<br /> # ' E provided by heat pump,waste heat recovery or solar water-heating systems.
<br /> t