EBDTDUCT LEAKAGE TEST RESULTS <br /> Blower Door Testing NW Date of Test: <br /> f , .,i <br /> 425-312-3914•BlowerDoorNW,corn 'Technician Name: LA.....luleC*e., 9_12/Let Ka t <br /> hip.wei.cloorseheciale(y),grnaitcom <br /> Job Site Information <br /> Permit ft: <br /> Address and Lot Number: IAL)S ( '.", ,t-i Vi etA) P <br /> ej C ucie 44-'-' <br /> P 1(..- <br /> l ' <br /> :-) <br /> i <br /> City: eidefOrk Zip Code: <br /> i <br /> Cond.Floor Area(ft2): . ‘SAge of House: Mej.,L) i <br /> i <br /> 1 <br /> Source(check one): , ans LI Estimated ta Measured <br /> /CPT , <br /> , <br /> : <br /> 1 <br /> LI Duct tightness testing is not required.The total leakage test is not required for ducts and air handlers located entirely <br /> within the building thermal envelope.Ducts located in crawl spaces do not qualify for this exception, <br /> Air Handler in conditioned space? CI Yes 211:11No Air Handler present during test? L 5/es U No <br /> Test Method: U.Leakage to Outside tal Leakage <br /> ev,„„. '"oi <br /> , <br /> iMaximum Duct Leakage <br /> i <br /> Post Construction,total duct leakage: (floor area x.04)= CFM@25 Pa 1 <br /> Post Construction,leakage to outdoors: (floor area x .04)= CFM@25 Pa 1 <br /> 1 <br /> Rough-In, total duct leakage with air handler installed: (floor area x .04)= j xilzeCFM@25 Pa I <br /> Rough-In,total duct leakage with air handler not installed: (floor area x .03)= CFM@25 Pa t <br /> i <br /> Test Result q2,111- CFM@,25Pa <br /> i <br /> Ring(check one if applicable) E3Pen LI I Cl 2 Cl 3 , <br /> 4 <br /> Duct Tester Location: \V(*Law- cek-u(iN Pressure Tap Location: (c (A,1-‘6(OA Vet\ "I— ' <br /> 0 - g <br /> I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. <br /> Technician Signature: <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.