Laserfiche WebLink
ENGINEERING <br /> PUBLIC SERVICES DEPARTMENT <br /> September 21, 2017 <br /> Ben Smith <br /> 4832 91st AVE NE <br /> Lake Stevens, WA 98258 <br /> RE: Owner: Smith <br /> Job Address: 2602 Cleveland Ave. <br /> Plan Check Number: C1706-011 <br /> Dear Mr. Smith, <br /> In response to your application for a construction permit, your plans have been examined and you <br /> are advised that the issuance of a permit is being withheld for the reasons listed below. These <br /> comments address building issues only. Additional revisions or additions may be required by other <br /> departments (such as Utilities, Planning or Fire). All references refer to the (2015 International <br /> Building Code,) (2015 International Residential Code,) as amended by the State of Washington <br /> and/or Washington State Energy Code 2015 Edition, and adopted by the City of Everett, unless <br /> stated otherwise. <br /> Review all code references when making the corrections to assure compliance. Do not copy the <br /> code reference as a correction onto the plan unless such reference is requested as a note to be <br /> incorporated into the plan. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested. <br /> Provide a square footage summary for each of the following: livable area, garage, covered <br /> patios and porches, accessory buildings, decks. C.lc careQ L iv4 cp ac. <br /> a(Show location of electrical panel on floor plan. <br /> GAIT partitions, doors and windows shall be located with dimensions on each floor level. <br /> Dimension all of the exterior walls on each floor level. <br /> ;Footing details (interior and exterior) shall be located on the foundation sheet or the detail <br /> sheet and shall be cross-referenced to the foundation plans. Specify depth into undisturbed soil <br /> for each footing type and condition and size of all footings and pads. Show all reinforcing steel <br /> (vertical and horizontal). <br /> 'Provide foundation ventilation calculations. Show size and location of foundation ventilation on <br /> foundation plan. <br /> Provide minimum 18"x 24"crawl space access. Show location on foundation plan. <br /> Zrovide minimum 6 mil black vapor barrier, Lap edges 12"show requirement on plans. <br /> 'age 1 ofi5 <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax(425) 257-88 <br />