My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2828 COLBY AVE 2020-06-16
>
Address Records
>
COLBY AVE
>
2828
>
2828 COLBY AVE 2020-06-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2020 1:56:22 PM
Creation date
6/16/2020 1:53:52 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2828
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i 1 <br /> EINW STRUCTURAL <br /> ENGINEERS <br /> Engineers Northwest Inc.,P.S. <br /> April 10, 2018 <br /> ag3T:irr <br /> SKOTDAL REAL ESTATE <br /> 2707 Colby Avenue APR 7 3 2Df8 <br /> Everett, WA 98270 <br /> czp�°F EVERETT <br /> ATTN: Gary O'Leary rr►rt Services <br /> RE: 2828 Colby Avenue— Everett,WA <br /> Second Building Permit Review Response <br /> Gary, <br /> Thank you for forwarding City of Everett plan review comments dated 4/2/18. The item <br /> numbers correspond to the comment numbers made by Drew Martin, P.E., S.E., <br /> Associate Engineer, Commercial Plans Examiner for the City of Everett. Structural <br /> comments are respectively addressed as follows: <br /> 2. See revised section 5/S1.1 for bolt spacing as requested. <br /> 5a. See Supplemental Calculations 02 for item 5a as requested. See revised <br /> section 5/S1.4 for added 3"x3"x1/4" steel washers welded to the%" vertical <br /> connection plate and for non-shrink grout added to the through bolts. <br /> 5b. See revised section 3/S1.4 for rebar couplers to reconnect original steel cut <br /> in previous work. <br /> 6. See new detail 15/S 1.3a. <br /> 7d. See added elevator bracket load plan on sheet S1.6 as requested. <br /> 13a. See Supplemental Calculations 02 for item 13a for existing plan of previous <br /> work. The existing opening appears to align with plank joint. A note is added to <br /> plans to notify ENW if field condition is not as shown. <br /> 13b. See revised section 2/S1.4 <br /> If you have any additional questions, please contact me for clarification. <br /> Sincerely, <br /> ENGI E,r. NO' , T, I C., P.S. <br /> if <br /> 4vnielin, P. :,""S.E. <br /> Senior Project Engineer APR 10 2018 1 .11 <br /> HP:bs CITY OF EVERETT <br /> We get ENW lob No. 17047000 Permit Services <br /> buildings <br /> built. <br /> • • <br /> K <br /> ��0 • 9725 Third Ave NE,Suite 207•Seattle,WA 98115 <br /> ` • 206.525.7560 • fax 206.522.6698 <br /> www.engineersnw.corn <br />
The URL can be used to link to this page
Your browser does not support the video tag.