3. Bathroom fixture clearances shall comply with Figure R307.1 Minimum Fixture <br /> Clearances. <br /> 4. The proposed bathroom in the existing basement does not have the minimum ceiling <br /> height. <br /> R305.1 Minimum height. Habitable space, hallways and portions of basements <br /> containing these spaces shall have a ceiling height of not less than 7 feet (2134 mm). <br /> Bathrooms, toilet rooms and laundry rooms shall have a ceiling height of not less than 6 <br /> feet 8 inches (2032 mm). <br /> 5. Provide smoke alarm in the area giving access to the Master Bedroom. <br /> 6. Show Energy Credit requirements on plans. <br /> HIGH EFFICIENCY HVAC EQUIPMENT 3b: <br /> Air-source heat pump with minimum HSPF of 8.5 <br /> To qualify to claim this credit, the building permit drawings shall specify the <br /> option being selected and shall specify the heating equipment type and the <br /> minimum equipment efficiency. <br /> EFFICIENT WATER HEATING 5a: <br /> Water heating system shall include one of the following: <br /> Gas, propane or oil water heater with a minimum EF of 0.62 <br /> or <br /> Electric water heater with a minimum EF of 0.93. <br /> and for both cases <br /> All showerhead and kitchen sink faucets installed in the house shall be rated at <br /> 1.75 GPM or less. All other lavatory faucets shall be rated at L0 GPM or less. <br /> To qualify to claim this credit, the building permit drawings shall specify the <br /> option being selected and shall specify the water heater equipment type <br /> and the minimum equipment efficiency and shall specify the maximum <br /> flow rates for all showerheads, kitchen sink faucets, and other lavatory <br /> faucets. <br /> 7. The stairs do not line up on the floor plan from one floor to the next. Provide full height <br /> building section at stairs. Show how minimum ceiling height (6 feet 8 inches) is achieved <br /> on all portions of the stairs. Show the rise and run of the stairs specific to this structure. <br /> 8. Provide section drawing of the proposed dormer in the front of the house at the second <br /> floor level. <br /> 9. Where insulation is compressed at the edge of the roof, R-49 insulation is required in <br /> the scissor trusses. <br /> 10.The basement floor plan shows a wall constructed on the interior of the below grade <br /> concrete walls. The wall is not shown in the section drawings. Please clarify. <br /> 11.The section drawings on sheet A-6.1 reference the structural drawings for anchor bolt <br /> size and spacing. The structural drawings do not clearly identify all walls in the <br /> S:\1Common\Clerical\]Heilman\C1509-012(6623 HIGHLAND DR).doc �_ .•• <br />