My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3323 HOYT AVE C D 2020-06-17
>
Address Records
>
HOYT AVE
>
3323
>
3323 HOYT AVE C D 2020-06-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 1:18:37 PM
Creation date
6/17/2020 1:17:48 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3323
Unit
C D
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11/27/2019 City of Everett Page <br /> 10:29:44AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. E1809-111 Site Address 3323 HOYT AVE C&D <br /> Applied 9/18/2018 Applicant Lot <br /> Approved 9/18/2018 Owner 3323 HOYT AVENUE LLC Block <br /> Issued 9/18/2018 Contractor SUMMIT ELECTRIC INC Tract <br /> Parent Permit No. B 1803-029 Description WIRE NEW DUPLEX <br /> Notes <br /> Scheduled Completed Tvue Inspector Result Remarks Inspector's Comments <br /> 2/22/2019 2/22/2019 ELEC 06-ROUGH SKB CORRECTION (2/22/2019 9:27 AM SKB) <br /> IN Provide a receptacle at the back of the <br /> building for each unit at grade level.In both <br /> units in the kitchen provide physical <br /> protection where conductors are ran outside <br /> of wall. <br /> 2/22/2019 2/22/2019 ELEC 05-SERVICE SKB CORRECTION (2/22/2019 9:27 AM SKB) <br /> Provide a grounding electrode conductor to <br /> the house service panel. <br /> 3/5/2019 3/5/2019 ELEC 05-SERVICE SKB CORRECTION Phone:425-308-5759 <br /> (3/5/2019 10:51 AM SKB) <br /> skb changed Inspection Type from ELEC <br /> 07-TGRID to ELEC 05-SERVICE <br /> (3/5/2019 10:51 AM SKB) <br /> The house panel is a service and must have <br /> its own grounding electrode system <br /> installed tied to the building electrodes. <br /> 3/5/2019 3/5/2019 ELEC 06-ROUGH SKB APPROVAL Phone:425-308-5759 <br /> IN <br /> 5/29/2019 5/29/2019 ELEC 05-SERVICE MCB APPROVAL <br /> 7/22/2019 7/22/2019 ELEC 09-FINAL MCB NOT READY <br /> 11/15/2019 11/15/2019 ELEC 09-FINAL SKB CORRECTION eTRAKiT Inspection 11/14/2019 5:09 PM SUMMIT ELECTRIC <br /> Request INC <br /> Contact Name:Lee Duncan <br /> Site Address:6133 261st ST NW <br /> Phone:4253085759 <br /> e-Mail:dncnldncn@gmail.com <br /> (11/15/2019 11:11 AM SKB) <br /> Provide GFCI protection for the garage door <br /> opener receptacles. <br /> 11/19/2019 11/19/2019 ADMIN USE KLC APPROVAL <br /> ONLY** <br /> 11/19/2019 11/19/2019 ELEC 09-FINAL SKB APPRVD-PERN eTRAKiT Inspection 11/18/2019 7:54 AM SUMMIT ELECTRIC <br /> Request INC <br /> Contact Name:Lee Duncan <br /> Site Address:6133 261st ST NW <br /> Phone:3609392431 <br /> e-Mail:dncnldncn@gmail.com <br /> INSP12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.