Laserfiche WebLink
' ,Use menu item Settings>Printing&Title k Title Page: 1 <br /> to set these five lines of information Job# Dsgnr: Date: 8 AUG 2017 <br /> for your program. Description.... <br /> This Wall in File:d:\sda archive\retainpro\7945.RPX <br /> RetainPro(c)1987-2015, Build 11.15.12.22 <br /> License:KW-06060593 Restrained Retaining Wall Code: IBC 2012,ACI 318-11,AC1 530-11 <br /> License To:STRUCTURAL DESIGN ASSOCIATES <br /> - Criteria I Soil Data I *.,,.M <br /> Retained Height = 7.50 ft Allow Soil Bearing = 1,500.0 psf050503'w- <br /> Wall <br /> w <br /> Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method <br /> Total Wall Height = 8.00 ft At-rest Heel Pressure = 55.0 psf/ft <br /> Top Support Height = 8.00 ft Passive Pressure = 250.0 psf/ft <br /> Soil Density = 110.00 pcf <br /> Slope Behind Wal = 0.00 FootingliSoil Frictior = 0.000 <br /> Height of Soil over Toe = 6.00 in Soil height to ignore <br /> for passive pressure = 0.00 in <br /> di m- <br /> Thumbnail <br /> Surcharge Loads A [Uniform Lateral Load Applied to Stem 0 Adjacent Footing Load <br /> Surcharge Over Heel = 90.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs <br /> >>>Used To Resist Sliding&Overturning Height to Top = 0.00 ft Footing Width = 0.00 ft <br /> Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in <br /> Used for Sliding&Overturning = <br /> Axial Load Applied to Stem I Load Type = Wind(W) Wall Dist e.Lo ft <br /> l Footing Ty <br /> TypeeLine Load <br /> (Strength Level) Base Above/Below Soil <br /> Axial Dead Load = 441.0 lbs at Back of Wall = 0.0 ft <br /> Axial Live Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf <br /> Axial Load Eccentricity = 0.0 in Poisson's Ratio = 0.300 <br /> Earth Pressure Seismic Load i Kh Soil Density Multiplier = 0.200 g Added seismic per unit area = 0.0 psf <br /> Stem Weight Seismic Load `Fp/Wp Weight Multiplier = 0.000 g Added seismic per unit area = 0.0 psf <br /> Design Summary ` Concrete Stem Construction 1 <br /> Total Bearing Load = 1,730 lbs Thickness = 8.00 in Fy = 40,000 psi <br /> ...resultant ecc. = 0.98 in Wall Weight = 100.0 psf fc = 2,500 psi <br /> Soil Pressure @Toe = 1,301 psf OK Stem is FREE to rotate at top of footing <br /> Soil Pressure @ Heel = 1,301 psf OK <br /> Allowable = 1,500 psf Mmax Between <br /> Soil Pressure Less Than Allowable @ Top Support Top&Base @ Base of Wall <br /> ACI Factored @ Toe = 988 psf Stem OK Stem OK Stem OK <br /> ACI Factored @Heel = 2,135 psf Design Height Above Ftp, = 8.00 ft 3.44 ft 0.00 ft <br /> Footing Shear @ Toe = 0.6 psi OK Rebar Size = # 4 # 4 # 4 <br /> Footing Shear© Heel = 2.6 psi OK Rebar Spacing = 9.00 in 9.00 in 9.00 in <br /> Allowable = 75.0 psi Rebar Placed at = Edge Edge Edge <br /> Reaction at Top = 640.6 lbs Rebar Depth 'd' = 5.50 in 6.00 in 5.50 in <br /> Reaction at Bottom = 1,643.1 lbs Design Data <br /> fb/FB+fa/Fa = 0.000 0.671 0.000 <br /> Sliding Calcs Mu.. .Actual = 0.0 ft-# 3,106.3 ft-# 0.0ft-# <br /> Lateral Sliding Force = 1,643.1 lbs <br /> Mn*Phi. ...Allowable = 4,232.2 ft-# 4,632-2 ft-# 4,232.2 ft-# <br /> Shear Force @ this height = 1,026.6 lbs 1,988.4 lbs <br /> Shear Actual = 15.55 psi 30.13 psi <br /> Shear Allowable = 75.00 psi 75.00 psi <br /> Vertical component of active lateral soil pressure IS Other Acceptable Sizes&Spacings: <br /> NOT considered in the calculation of soil bearing Toe: #4 @ 18.00 in -or- Not req'd: Mu <phi*5*lambda*sgrt(fc)*Sm <br /> Heel:#4 @ 18.00 in -or- Not req'd: Mu <phi*5*lambda*sgrt(fc)*Sm <br /> Load Factors - - - - - Key: No key defined -or- No key defined <br /> Building Code IBC 2012,ACI <br /> Dead Load 1.200 <br /> Live Load 1.600 /40 <br /> Earth, H 1.600 (00 <br /> Wind,W 1.000 <br /> Seismic, E 1.000 <br />