My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3623 HOYT AVE 1-3 2020-06-17
>
Address Records
>
HOYT AVE
>
3623
>
3623 HOYT AVE 1-3 2020-06-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 3:02:40 PM
Creation date
6/17/2020 2:58:30 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3623
Unit
1-3
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> . Simple Heating System Size:Washington State , Iv i) U "� ` �- <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> • Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Sidhu Properties-Trip;ex Residence American Home Planners <br /> i Unit B and Unit C (425)258-6400 <br /> Heating System Type: ®All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions Design Temperature Difference(AT) 47 <br /> Everett JC --_--_ —__—� AT.Indoor(70degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Inr,truct€cns Conditioned Floor Area(sq ft) 728 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.0 5,824 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 110 33.00 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 <br /> - - - Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions R-49 . 0.026 728 18.93 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> instructions I No Vaulted Ceilings in this project.- --- <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions R-21 Intermediate wr 0.056 1,008 56.45 <br /> Floors U-Factor X Area UA <br /> Instructions <br /> Lo Floors above unconditional spaces. <br /> I , <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions Co Below Grade Walls in this project. <br /> Slab Below Grade(ace Figure1) F-Factor XLe� UA <br /> Instructions — _No Slab Below Grade In this project --- <br /> Slab on Grade pee Figural) F-Factor X Len•th UA <br /> In!tractions No Slab on Grade in this project. ', --- 156 <br /> Location of Ducts <br /> Instructions -- Duct Leakage Coefficient <br /> No Ducts ---.-- ---- � I 1.00 <br /> Sum of UA 108.38 <br /> Envelope Heat Load 5,094 Btu/Hour <br /> • <br /> Figure 1. Sum of UAX AT <br /> Air Leakage Heat Load 2,956 Btu/Hour <br /> VolumeX 0.6X ATX.018 <br /> Above Grade Building Design Heat Load 8,050 Btu/Hour <br /> Air Leekago+Envelope Heat Loss <br /> Building and Duct Heat Load 8,050 Btu/Hour <br /> Ducts In unconditioned space:Sum of Building Heat Loss X 1.10 <br /> • Ducts In conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 11,270 Btu I Hour <br /> Building and Duct Heat Loss X 1.40 forForced Air Furnace <br /> Building and Duct Heat Loss X 1.26 for-Haat Pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.