UTILITY VAULT CO. PARTS NOTES <br /> SIZE MODEL COVER <br /> 2 1/2" 644 64-2-332P 0 'OST INDICATOR VALVE PAINTED RED WITH TAMPER TO 1. TEE AND GATE VALVE REQUIRED ON MAIN. <br /> 3" 644 64-2-332P ,:IRE ALARM PANEL AND WITH STENCILED ADDRESS. <br /> 4" 575 57TL-2-332P 2. SINGLE DETECTOR CHECKS ARE NOT APPROVED BACKFLOW <br /> 2. 'DUCTILE IRON PIPE (SIZED AS REQUIRED) CLASS 52. <br /> 6" 577 57TL-2-332P O PREVENTION DEVICES. <br /> 8" 4484 4484-TL2-332P 3 ;CHEDULE 40 GALV. STEEL WRAPPED W/6MIL PLASTIC. <br /> 10" 5106 5106-1L3-332 ` + 0 0 3 AND RE-CERTIFICATION QUIRES EANINIUALLY BY OWNER.CATION UPON STALLATION <br /> 4. CLASS 52 DI TEE FL X FL. <br /> 0 O SWING CHECK VALVE W/BALL DRIP ASSEMBLY. 4. ALL TEST COCKS MUST HAVE BRASS PLUGS. <br /> I ,. 0 0 O6. FIRE DEPARTMENT CONNECTION (BRASS) LOCATED WITHIN 5. ROUND MANHOLE LIDS ARE NOT TO BE USED. <br /> _ _am = 75' OFA FIRE HYDRANT FOR NEW BUILDINGS (OR 100' FOR 6. INSIDE DEPTH IS TO BE KEPT AT A MINIMUM AS PER <br /> AN EXISTING BUILDING BEING RETROFIT FOR SPRINKLERS) DIMENSION IN SKETCHES ABOVE AND/OR <br /> © _ PROVIDE KNOX LOCKING CAPS. EXPOSED GALVANIZED <br /> ■'( a STEEL PIPE TO BE PAINTED RED. STENCIL ADDRESS ON AS APPROVED BY CITY OF EVERETT UTILITIES DEPARTMENT. <br /> O 0 ?AINTED PIPE. 7. METER SHALL BE INSTALLED SUCH THAT IT CAN BE READ <br /> 1 TO BUILDING O ALL PIPE THROUGH VAULT WALL SHALL BE CORE DRILLED WITH ACCESS HATCH OPEN AND WITHOUT ENTERING THE <br /> L- AND HAVE A "LINK SEAL" (OR APPROVED EQUAL). VAULT. <br /> Win-. �� 9I I•RI;9I I� �� ;, -i 8. ALL DIMENSIONS ARE MINIMUM CLEARANCE. <br /> 08. OS &Y VALVES WITH TAMPER SWITCH TO ALARM PANEL OR <br /> • <br /> CHAIN AND PADLOCK. 9. ALL BACKFLOW DEVICES WILL BE INSTALLED IN A VAULT <br /> 10191:010101 O <br /> 0 <br /> 0OUTSIDE THE BUILDING UNLESS OTHERWISE APPROVED BY <br /> . LADDER WITH PULL-UP LADDER EXTENSION <br /> BOLTEDUTILITIES SUPERINTENDENT. <br /> TO VAULT FLOOR AND TO VAULT WALL, MOUNTED <br /> TEE D <br /> - ®— J SUCH THAT LADDER IS DIRECTLY ABOVE THE EDGE OF <br /> ACCESS OPENING FOR EASE OF ACCESS. 10. FIRE SERVICE PIPINGS FROM MAIN TO BUILDING SHALL BE <br /> -TAMPER SWITCH RESTRAINED. <br /> - IF REQUIRED 10. UL-FM LISTED SOFTSEATED WA STATE APPROVED DOUBLE <br /> CHECK DETECTOR VALVE ASSEMBLY INCLUDING 2-0.S.&Y 11. THE FOLLOWINGS FOR ORDER OF R THE VAULT SHALL BE IN <br /> -- - THE ORDER OF PRECEDENCE: <br /> PLAN RESILIENT SEATED GATE VALVES,TEST COCKS, 3/4" BRASS <br /> OR COPPER BYPASS WITH INLINE VALVES, 5/8" X 3/4" A) VAULT DRAIN TO DAYLIGHT <br /> NEPTUNE METER W/E-CODER R900 I, CU FT W/STUB B)VAULT DRAIN TO STORM DRAIN SYSTEM (IF PRACTICAL) <br /> PROVIDE 9" MINIMUM AND 12" ANTENNA& A 3/4" DOUBLE CHECK VALVE ASSEMBLY. C) IF NO POSSIBLE MEANS OF GRAVITY DRAIN, THEN <br /> MAXIMUM CLEARANCE BETWEEN ® INSTALL SUMP PUMP <br /> VAULT FLOOR AND BOTTOM OF 11. STATE APPROVED DOUBLE CHECK DETECTOR ASSEMBLY. <br /> BACKFLOW ASSEMBLY. WHERE O O «A12. SWING CHECK VALVE ON FDC LINE MUST BE LOCATED IN A <br /> � TAMPER <br /> 12. RFCA (RESTRAINED FLANGE COUPLING ADAPTER). VAULT. IF OUTSIDE OF DCDA VAULT, MUST BE IN <br /> ELEVATION OF VAULT FLOOR IS TOO = •.. MINIMUM 4'X4' VAULT. <br /> LOW TO DRAIN TO DAYLIGHT ORSWITCH IF 13. CUTABLE PADLOCK WITH KEY IN KNOX BOX. <br /> an <br /> STORM SYSTEM, MUST HAVE 6" 1' _ REQUIRED 13. PIV LOCATION MUST BE DOWNSTREAM OF DCDA AND <br /> FLOOR OPENING FOR DRAINAGE TAMPER UPSTREAM OF FDC. <br /> I <br /> (APPROVED BY THE CITY ENGINEER I <br /> ON A CASE BY CASE BASIS ONLY). 41)---\ I---- STENCILED ADDRESS RAISED LETTERS <br /> � "AUTO SPRINKLER" <br /> 20 <br /> I �I + SCHEDULE 40 <br /> — - 2-1/2" FIRE I -I GALVANIZED STEEL <br /> Y �� �! - DEPARTMENT INLET PAINTED RED <br /> 11111 ' :I 1 1 ;71- <br /> 0 N CONNECTION 18"X18"X8" <br /> BRASS (NOT CONC. BLOCK <br /> O PAINTED)"AUTO <br /> 9 �'' � C::_ ' SPRINKLER" <br /> 1 I J D J� I I-4 I 1 <br /> L, - - <br /> 0 <br /> 1 1 1 1 1 10 O ° 0 1 1 1 g <br /> I1 <br /> 11 fl h 1 . <br /> ______, <br /> ,, __t- U •• <br /> zQ 0 0 <br /> '' ® SCHEDULE 40 .. I CITY OF EVERETT <br /> 0 O1 GALVANIZED STEEL <br /> I t___. i i_ _ WRAPPED WITH 6 H____ PUBLIC WORKS DEPARTMENT <br /> `^ M I L PLASTIC y Engineer Section Manager FD Manager Drawn ey ent Rev Date <br /> L, RYAN SASS R HEFTI PAUL WILHELM WRB 12/08/2018 <br /> 8 POSITIVE VAULT DRAIN ® FIRE DEPARTMENT CONNECTION TITLE DOUBLE CHECK DETECTOR <br /> 2 STANDARD <br /> DRAWING No. <br /> ELEVATION FRONT ELEVATION VALVE ASSEMBLY W/FDC & PIV <br /> 515 <br /> ,, (DCDA) 2" & LARGER SERVICE <br />