Laserfiche WebLink
Ill T ! II MI <br /> THE SIDHU PROPERTY -. _ o-•-vni6ver 29, 2016 SDA Job # 7945 b' "A <br /> WIND <br /> UPPER FRONT WALL SHEARWALL SEISMIC <br /> Floor Into Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> UPPER Floor Level,e.g. Upper,Main,Lower 1.0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type tributary width tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 total width total area <br /> ROOF Resisting Dead Load Not Used Not Used <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 24.00 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 2868 lb 4131 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> V(from main)= 0 lb 0 lb Length of Shearwall= 3.5 ft Tributary width for dead load= 6.0 ft <br /> V(from lower)= 0 lb 0 lb : ,:. Length of adjoining wall= 4.0 ft • <br /> E(Wind)= 2,868 lb E(Smc)= 4,131 lb Use alternate R factor for seismic? NO <br /> v= 60 PLF v= 86 PLF <br /> AF&PA SDPWS-2008 (2w/h) x 0.93 x 230= 187 PLF USE 1 <br /> CTOTAL = (floor above)+(this floor)= + 482 lbs = 482 lbs Seismic controls <br /> TTOTAL= (floor above) +(this floor)= + 181 lbs = 181 lbs Load case 8 controls-Wind <br /> 1 <br /> Where overstrength factor is applicable,use this <br /> NO HOLDOWNS REQUIRED OK <br /> value for E in equations 5.,6.,and 8: E= 689 lbs a <br /> UPPER REAR WALL SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> UPPER Floor Level,e.g. Upper,Main,Lower 1.0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction,e.g. Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type tributary width tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 total width total area <br /> ROOF Resisting Dead Load Not Used Not Used <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 16.00 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 2868 lb 4131 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> V(from main)= 0 lb 0 lb Length of Shearwall = 8.0 ft Tributary width for dead load= 6.0 ft <br /> V(from lower)= 0 lb 0 lb Length of adjoining wall= 4.0 ft <br /> E(S2tvS)= 2,868 lb E(41)0= 4,131 lb Use alternate R factor for seismic? No <br /> v= 90 PLF v= 129 PLF <br /> AF&PA SDPWS-2008 0.93 x 230= 214 PLF USE 1 <br /> CTOTAL = (floor above)+(this floor)= + 723 lbs = 723 lbs Seismic controls <br /> TTOTAL= (floor above) +(this floor)= + 304 lbs = 304 lbs Load case 8 controls-Wind <br /> Where overstrength factor is applicable,use this NO HOEDOWNS REQUIRED OK <br /> value for E in equations 5.,6,and 8: E= 1033 lbs <br /> UPPER LEFT/RIGHT WALL SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> UPPER Floor Level,e.g. Upper,Main,Lower 1.0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type tributary width tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 total width total area <br /> ROOF Resisting Dea_d_Load _ Not Used Not Used <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 33.50 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 3082 lb 4131 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> V(from main)= 0 lb 0 lb Length of Shearwall= 16.0 ft Tributary width for dead load= 6.0 ft <br /> V(from lower)= 0 lb 0 lb Length of adjoining wall= 4.0 ft <br /> E(SINS)= 3,082 lb 4(En)= 4,131 lb Use alternate R factor for seismic? No <br /> v= 46 PLF v= 62 PLF <br /> AF&PA SDPWS-2008 0.93 x 230= 214 PLF USE 1 <br /> CTOTAL = (floor above)+(this floor)= + 368 lbs = 368 lbs Wind controls <br /> TTOTAL = (floor above) + (this floor)= + -252 lbs = -252 lbs Load case 8 controls-Wind <br /> Where overstrength factor is applicable,use this NO HOLDOWNS REQUIRED OK <br /> value for E in equations 5_,6,and 8: E= 493 lbs <br />