My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1910 74TH ST SE 2020-06-19
>
Address Records
>
74TH ST SE
>
1910
>
1910 74TH ST SE 2020-06-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2020 8:27:01 AM
Creation date
6/19/2020 8:17:34 AM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SE
Street Number
1910
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Name/Number:0956 foundati <br /> ' Use menu item Settings>Printing&Title Block Title PYATAK Page: 1 <br /> to set these five lines of information Dsgnr: amg Date: 4 DEC 2018 <br /> for your program. Description.... <br /> 4'CANT <br /> This Wall in File: c:\users\amgah\onedrive\upst8 main\2018(0867-xxxx yellow)\0956 vladimir pyatak- <br /> RetainPro(c)1987-2018, Build 11.18.11.29 <br /> License:KW-06060767 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13 <br /> License To: Upstate Engineering <br /> Criteria I Soil Data <br /> Retained Height = 3.50 ft Allow Soil Bearing = 1,500.0 psf <br /> Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method '" <br /> Active Heel Pressure = 35.0 psf/ft <br /> Slope Behind Wall = 0.00 <br /> Height of Soil over Toe = 8.00 in = <br /> Water height over heel = 0.0 ft Passive Pressure = 305.0 psf/ft <br /> Soil Density,Heel = 110.00 pcf <br /> Soil Density,Toe = 0.00 pcf <br /> FootingiiSoil Friction = 0.400 ., <br /> Soil height to ignore <br /> for passive pressure = 12.00 in <br /> Surcharge Loads 1 Lateral Load Applied to Stem I Adjacent Footing LoadII <br /> Surcharge Over Heel = 0.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs <br /> Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft <br /> Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in <br /> Used for Sliding&Overturning Load Type = Wind(W) Wall to Ftg CL Dist = 0.00 ft <br /> Axial Load Applied to Stem hiLoad <br /> Level) Footing Type Line Load <br /> Base Above/Below Soil 0.0 ft <br /> Axial Dead Load = 235.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall <br /> Axial Live Load = 335.0 lbs (Service Level) <br /> Axial Load Eccentricity = 0.0 in Poisson's Ratio = 0.300 <br /> Design Summary I Stem Construction 1 Bottom <br /> Stem OK <br /> - <br /> Wall Stability Ratios Design Height Above Ftc ft= 0.00 <br /> Overturning = 3.18 OK Wall Material Above"Ht" = Concrete <br /> Sliding = 2.26 OK Design Method = LRFD <br /> Thickness = 8.00 <br /> Total Bearing Load = 1,736 lbs Rebar Size = # 4 <br /> ...resultant ecc. = 2.13 in Rebar Spacing = 12.00 <br /> Soil Pressure @ Toe = 1,496 psf OK Rebar Placed at = Edge <br /> Design Data <br /> Soil Pressure @ Heel = 398 psf OK fb/FB+fa/Fa = 0.108 <br /> Allowable = 1,500 psf Total Force @ Section <br /> Soil Pressure Less Than Allowable Service Level lbs= <br /> ACI Factored @ Toe = 1,690 psf <br /> ACI Factored @ Heel = 449 psf Strength Level lbs= 343.0 <br /> Moment....Actual <br /> Footing Shear @ Toe = 2.1 psi OK Service Level ft-#_ <br /> Footing Shear @ Heel = 0.3 psi OK Strength Level ft-#= 400.2 <br /> Allowable = 75.0 psi <br /> Sliding Calcs Moment Allowable = 3,655.6 <br /> Lateral Sliding Force = 316.1 lbs Shear Actual <br /> less 100%Passive Force= - 153.6 lbs Service Level psi= <br /> less 100%Friction Force = - 560.3 lbs Strength Level psi= 4.6 <br /> Added Force Req'd = 0.0 lbs OK Shear Allowable psi= 75.0 <br /> ....for 1.5 Stability = 0.0 lbs OK Anet(Masonry) in2= <br /> Rebar Depth 'd' in= 6.25 <br /> Masonry Data - <br /> fm psi= <br /> Fs psi= <br /> Solid Grouting = <br /> Vertical component of active lateral soil pressure IS Modular Ration' = <br /> NOT considered in the calculation of soil bearing Wall Weight psf= 100.0 <br /> Load Factors Short Term Factor = <br /> Building Code IBC 2015,ACI Equiv.Solid Thick. = <br /> Dead Load 1.200 Masonry Block Type = Medium Weight <br /> Live Load 1.600 Masonry Design Method = ASD <br /> Earth, H 1.600 Concrete Data <br /> Wind,W 1.000 f'c psi= 2,500.0 <br /> Seismic, E 1.000 Fy psi= 40,000.0 <br /> 3 _l.y' <br />
The URL can be used to link to this page
Your browser does not support the video tag.