Geotechnical Report <br /> Proposed Development: 11229 - 19th Avenue SE, Everett, WA <br /> September 16, 2016 <br /> 5.4 RETAINING WALL DESIGN PARAMETERS <br /> Retaining and basement walls should be properly designed to resist the lateral earth pressures <br /> exerted by the soils behind the wall. Proper drainage provisions should also be provided behind <br /> the walls to intercept and remove groundwater that may be present behind the wall. Our <br /> geotechnical recommendations for the design and construction of the retaining/basement walls are <br /> presented below. <br /> 5.4.1 Lateral Earth Pressures <br /> Concrete cantilever walls should be designed for an equivalent fluid pressure of 35 pcf for level <br /> backfills behind the walls assuming the walls are free to rotate. If walls are to be restrained at the <br /> top from free movement, such as below-grade and building and basement walls, equivalent fluid <br /> pressures of 45 pcf should be used for level backfills behind the walls. Walls with a maximum <br /> 2H:1V backslope should be designed for an active and at rest earth pressure of 45 and 55 pcf, <br /> respectively. <br /> Permanent walls should be designed for an additional uniform lateral pressure of 7H psf for seismic <br /> loading, where H corresponds to the buried depth of the wall. The recommended lateral pressures <br /> assume that the backfill behind the wall consists of a free draining and properly compacted fill <br /> with adequate drainage provisions. <br /> 5.4.2 Surcharge <br /> Surcharge loads, where present, should also be included in the design of retaining walls. We <br /> recommend that a lateral load coefficient of 0.3 be used to compute the lateral pressure on the wall <br /> face resulting from surcharge loads located within a horizontal distance of one-half the wall height. <br /> 5.4.3 Lateral Resistance <br /> Lateral forces from seismic loading and unbalanced lateral earth pressures may be resisted by a <br /> combination of passive earth pressures acting against the embedded portions of the foundations <br /> and by friction acting on the base of the wall foundation. Passive resistance values may be <br /> determined using an equivalent fluid weight of 300 pcf. This value includes a factor of safety of <br /> 1.5, assuming the footing is backfilled with structural fill. A friction coefficient of 0.30 may be <br /> used to determine the frictional resistance at the base of the footings. The coefficient includes a <br /> factor of safety of 1.5. <br /> 16-210 11229 19th Ave SE Rpt Page 11 PanGEO, Inc. <br />