Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> 703 110th PL SE RAD <br /> Everett,WA 2812 Colby Ave <br /> Everett,WA <br /> Heating System Type: e All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word'Instructions". <br /> Design Temperature <br /> Instructions Design Temperature Difference(AT) 47 <br /> Everett IC E.7 AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 460 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.0 3,680 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 46 13.80 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 0 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> R-49 0.026 460 11.96 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> instructions Select R-Value .. No selection 0 <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions R-21 Intermediate 0.056 528 29.57 <br /> Floors ___ - U-Factor X Area UA <br /> Instructions --- 850 <br /> No Floors above unconditioned spaces. <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions Select R-value No selection 0 --- <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Select conditioning No selection 0 --- <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions 0.540 0 <br /> R-10 Perimeter <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> Unconditioned Space <br /> 1.10 <br /> Sum of UA 55.33 <br /> Envelope Heat Load 2,600 Btu/Hour <br /> Figure 1. sum ofuAXAT <br /> Air Leakage Heat Load 1,868 Btu/Hour <br /> VolumeX 0.6XATX.018 <br /> Above Glade Building Design Heat Load 4,468 Btu/Hour <br /> .."""""° <br /> "^ Air Leakage+Envelope Heat Loss <br /> Below Grad <br /> Building and Duct Heat Load 4,915 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 6,881 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />