Laserfiche WebLink
BeamChek v2013 licensed to:Three Nail Designs Reg#8551-66863 <br /> Speck <br /> BDR 2 Closet Prepared by:JWH Date:4/02/16 <br /> Selection 4x 8 DF-L#2 Lu=0.0 Ft <br /> Conditions NDS 2012 <br /> Min Bearing Area R1=2.3 in2 R2=2.3 in2 (1.5)DL Defl= 0.05 in <br /> Data Beam Span 6.0 ft Reaction 1 LL 900# Reaction 2 LL 900# <br /> Beam Wt per ft 6.17# Reaction 1 TL 1458# Reaction 2 TL 1458# <br /> Bm Wt Included 37# Maximum V 1458# <br /> Max Moment 2188'# Max V(Reduced) 1165# <br /> TL Max Defl L/240 TL Actual Defl L/759 <br /> LL Max Defl L/360 LL Actual Defl L/>1000 <br /> Attributes Section(ins) Shear(int) TL Defl(in) LL Defl <br /> Actual 30.66 25.38 0.09 0.05 <br /> Critical 22.44 9.71 0.30 0.20 <br /> Status OK OK OK OK <br /> Ratio 73% 38% 32% 25% <br /> Fb(psi) Fv(psi) E(psi x mil) Fc I(psi) <br /> Values Reference Values 900 180 1.6 625 <br /> Adjusted Values 1170 180 1.6 625 <br /> Adjustments CF Size Factor 1.300 <br /> Cd Duration 1.00 1.00 <br /> Cr Repetitive 1.00 <br /> Ch Shear Stress N/A <br /> Cm Wet Use 1.00 1.00 1.00 1.00 <br /> Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft <br /> Loads Uniform LL:300 Uniform TL: 480 =A <br /> Uniform Load A <br /> Rl=1458 R2=1458 <br /> SPAN=6 FT <br /> Uniform and partial uniform loads are lbs per lineal ft. <br /> f�. <br /> 9` <br /> 0 <br />