Laserfiche WebLink
PROJECT NOTES ELECTRICAL LEGEND <br /> 1. GENERAL:WORK SHALL BE DONE IN ACCORDANCE WITH CODES AS 10. SCOPE OF WORK:THE SCOPE OF WORK FOR THIS PROJECT INCLUDES BUT IS DIAGRAMS WIRING DIAGRAMS LIGHTING-EXISTING(SURVEY) LIGHTING <br /> ADOPTED BY THE CITY OF EVERETT,SNOHOMISH COUNTY,AND THE NOT LIMITED TO THE FOLLOWING: SYMBOL DESCRIPTION SYMBOL I DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br /> STATE OF WASHINGTON. O UTILITY OMR-POLE MOUNTED ESD LUMINAIRE,TYPES A-25&A2-18 <br /> KVA,VOLTAGE,PHASE -. OH—SNOPUD 12471(0 OVERHEAD UNE �__" CITY STREET LIGHT <br /> A. INSTALLATION OF UNDERGROUND INFRASTRUCTURE(INCLUDING THOSE ITC WITH FIXTURE ARM p.o-a LUMINAIRE,TYPE A1-18/25 <br /> 2. LOCATIONS OF ELECTRICAL EQUIPMENT,DEVICES,LIGHTING FIXTURES, REQUIRED BY POWER AND TELECOMMUNICATIONS PROVIDERS), A- (uTIUTY A IF APPLICABLE) P SNOPUD 12471(0 UNDERGROUND LINE <br /> ETC.,INDICATED ON CML/STRUCTURAL AND LANDSCAPE PLANS- ROADWAY AND SITE LIGHTING,ELECTRICAL POWER DISTRIBUTION. J MIR-(MOUNTING) CONDUIT RACEWAY STREET LIGHTING POLE CO-m LUMINAIRE,TYPE A4-14 <br /> INCLUDING SECTIONS,ELEVATIONS,NOTES,OR OTHER INDICATORS- CONTROLS,AND APPURTENANCES,AS SHOWN HEREIN. KVA VOLTAGE,PHASE CONTROL/INSTRUMENT WIRING WITIT ARM AND FIXTURE <br /> TAKE PRECEDENCE OVER LOCATIONS SHOWN ON ELECTRICAL S -A-xxx'(UTILITY A IF APPLICABLE) CO- -C3 LUMINAIRE,TYPE A4-14/18 <br /> CONDUIT UNE WEIGHT STREET UGHTING POLE <br /> DRAWINGS. B. DEMOLITION:REMOVE EXISTING COMPONENTS AS INDICATED. O /.J WITH TWO ARMS AND FIXTURES <br /> COORDINATE WITH SNOHOMISH PUD,FRONTIER COMMUNICATIONS,AND Foe METER W/CURRENT TRANSFORMER CONDUIT EXISTING UNE BEGOT (-O LUMINAIRE,TYPE A3-14 <br /> M=UTILITY CO.APPROVED SOCKET WTI METER E— CONDUIT RACEWAY SNB-OUT (j- FLOODLIGHT FIXTURE, <br /> 3. REFER TO CIVIL,STRUCTURAL,LANDSCAPE,ETC.,DRAWINGS FOR WORK WAVE COMMUNICATIONS(FIBER OPTICS),FOR PHASED REMOVAL AND ®� PF=POWER FACTOR METER fF <br /> IN OTHER DIVISIONS.INFORMATION CONVEYED WITHIN THE ELECTRICAL RECONNECTION OF SERVICES.NOTE:SEQUENCE INSTALLATION OF KW/KVAR=COMBINATION KILOWATTHOUR/KVAR LIGHTING POLE WITH TOP/ : REMOVE EXISTING LUMINAIRE AND RETAIN FOR REUSE <br /> I� DEMOUSH EXISTING FOUNDATION,RECONNECT CONDUIT. <br /> DRAWINGS ILLUSTRATING OR REFERENCING WORK OF OTHER DIVISIONS SUPPORTING INFRASTRUCTURE-CONDUIT,VAULTS,ETC.-TO LIMIT <br /> IS FOR REFERENCE ONLY.SPECIFICATION BY THE RELEVANT DIVISIONS OUTAGE TIMES AS PRESCRIBED(SEE NOTE BELOWCENTER MOUNTED FIXTURE <br /> ). E CURRENT TRANSFORMER XXX'RR' BOXES AND WIRING AS REQUIRED FOR NEW CONSTRUCTION <br /> SHALL APPLY. REFERENCE SYMBOLS 4"[e' LIGHTING BOLLARD =Hm REMOVE AND REPLACE EXISTING LUMINAIRE <br /> C. PERMITS:GIVE ALL NECESSARY NOTICES,OBTAIN ALL PERMITS AND GF GROUND FAULT RELAY SYMBOL DESCRIPTION l SURFACE OR RECESSED PPACKKAGE OE AND STORE AT LOCATION DESIGNATED <br /> 4. GENERAL NOTES ARE SHOWN ON SHEETS MOST RELEVANT TO SPECIFIC PAY ALL GOVERNMENT TAXES,FEES AND OTHER COSTS IN CONNECTION FIXTURE(IE..PROMENADE LIGHTING) <br /> NOTE;HOWEVER,GENERAL NOTES ON EACH SHEET SHALL APPLY IN WITH THIS WORK.OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION I ink REFER TO DETAIL NO.ON DRAWING INDICATED NOT ALL r, SIGN UGHTING FL000UGHT 0 LIGHTING BOLLARD,TYPES S1-O&82-X <br /> PRACTICE TO ALL ELECTRICAL DRAWINGS. OF THE WORK AND DELIVER SAME TO THE ENGINEER AT THE TIME OF , CIRCUIT BREAKER DETAIL REFERENCES ARE SHOWN.ALL DETAILS APPLY <br /> SUBSTANTIAL COMPLETION AND BEFORE REQUEST FOR FINAL PAYMENT. J 1IX10/y mot=AMPACITY,y=POLES TO ALL APPLICABLE SITUATIONS,LION. R12 <br /> 5. NOT ALL COMPONENTS OF THE ELECTRICAL SYSTEMS ARE SHOWN(FOR I ( RECESSED FIXTURE,TYPE DES <br /> SIMPLICITY).PROVIDE MATERIALS AND LABOR NECESSARY FOR A D. PHASING:PHASED INSTALLATION WILL BE NECESSARY.COORDINATE Sx7TCH (ESPLANADE HANDRAIL PEDESTAL) <br /> COMPLETE AND OPERATIONAL SYSTEM. MOBILIZATION AND DEMOBILIZATION REQUIREMENTS WITH OTHER `xx xxx=AMPACITY AIM ELEVATION TAG OR IMAGE VIEW: REFER TO NUMBER ) ) SGN LIGHTING FLOODUGHT <br /> TRADES AND THE GENERAL CONTRACTOR. INCLUDE,IN BASE BID,ALL AND SHEET INDICATED ® CAST IN PLACE FIXTURE-LED <br /> 6. STAINLESS STEEL HARDWARE:MATERIALS USED FOR THE MOUNTING COSTS FOR MOBILIZATION AND DEMOBILIZATION PRIOR TO FINAL im DISCONNECT SWITCH TYPE G1(TRADING PARTNER ROUTE) <br /> AND SUPPORT OF BOXES CABLES,RACEWAYS,LIGHT FIXTURES, COMPLETION. zx-AMPACITY <br /> OUTLETS,AND OTHER ELECTRICAL EQUIPMENT,SHALL BE 316DISCONNECT SWITCH-FUSED CAST IN PLACE,LIGHTING FIXTURE. <br /> Jai <br /> TYPE G2(TRADING PARTNER ROUTE) <br /> STAINLESS STEEL.THIS REQUIREMENT APPLIES TO THE E. POWER OUTAGES:POWER OUTAGES SHALL BE LIMITED TO THE HOURS VI o1 xx=AMPACITY CAST IN PLACE,GRADE LIGHTING FIXTURE, <br /> AFOREMENTIONED COMPONENTS WHEN INSTALLED OUTSIDE ABOVE OF 6:00PM TO 7:00AM WEEKDAYS OR WEEKENDSMOUDAYS.OUTAGES SECTION TAG: REFER TO DETAIL N0.ON DRAWING. <br /> NOT ALL DETAIL REFERENCES ARE SHOWN.ALL TYPE R3(GLOBE ILLUMINATION) <br /> GRADE OR OVER WATER. SHALL BE REQUESTED IN WRITING TO THE OWNER 7-DAYS PRIOR TO O JUNCTION BOX DETAILS APPLY. • CAST IN PLACE,PATH LIGHTING FIXTURE, <br /> THE DESIRED DATE AND TIME.NO OUTAGE SHALL OCCUR WITHOUT THE L L TYPE R3A(PLAZA) <br /> 7. LOCATIONS OF ELECTRICAL SYSTEMS COMPONENTS,INCLUDING BUT PRIOR APPROVAL OF THE OWNERS REPRESENTATIVE.OUTAGES SHALL /„` MOTOR OR PUMP,AS NOTED © SURFACE MOUNTED LINEAR STRIP-LED <br /> NOT LIMITED TO,LUMINAIRES,DISTRIBUTION EQUIPMENT,CONDUIT, NOT EXCEED(8)CONSECUTIVE HOURS. y y OX SHEET NOTE REFERENCE TYPE S2-XX((0(=LENGTH) <br /> JUNCTION BOXES,VAULTS,ETC.,MAY BE REVISED PRIOR TO <br /> CONSTRUCTION.CHANGES MADE BY THE OWNER IN LOCATING F. TEMPORARY POWER:PROVIDE TEMPORARY POWER AS NEEDED BY ALL ® SPECIAL RECEPTACLE SNOPUD 12.a7Kv H.V.CABLE p1RRENT OR NNRE. H CAST OR T IN R12(PLAZA LAZA TYPE RIOSEAANLL) 1(STAIR) <br /> ELECTRICAL COMPONENTS OF UP TO THIRTY FEET HORIZONTALLY TRADES DURING THE EXECUTION OF THIS CONTRACT.THIS INCLUDES ( P-HV ) PROVIDE WIRE ANC RACEWAY WHERE SHOWN <br /> (AND/OR VERTICALLY)ISA PART OF THIS CONTRACT.CHANGES IN INTERIM POWER REQUIREMENTS MADE NECESSARY DUE TO PHASED 0 UGHTING/POWER PEDESTAL 30 J FEEDER TAC NOMINAL AMPACITY h TYPE SEE FEEDER O LANDSCAPE HELL UP-LIGHT FIXTURE, <br /> LOCATION MAY BE IMPLEMENTED,AT NO CHARGE TO THE OWNER,WHEN CONSTRUCTION.WHEN APPROVED BY THE OWNER IN ADVANCE, SCHEDULE ON DWL Eo.o1 TYPE T1(TREE) <br /> MADE PRIOR TO ROUGH-IN OF EQUIPMENT BEING RELOCATED. PROVIDE TEMPORARY POWER CONNECTIONS TO PERMANENT SERVICES UGHTING CONTROLLER 20"C <br /> IF OUTAGES ARE LONGER IN DURATION THAN SPECIFIED IN THE LIE TC TC=11MECLOCK CONTROLLED 3Q•3 CONDUIT IN SIZE SHOW WITH FEEDER AS INDICTED <br /> 8. COORDINATE LOCATIONS OF ELECTRICAL AND COMMUNICATION PARAGRAPH ABOVE OR IF OUTSIDE THE SPECIFIED TIME OF DAY. HOA=HAND-OFF-AUTO SWITCH CONTROLLED <br /> CHASES AND CONDUITS WITH OTHER TRADES.ADJUST LOCATIONS AS TEMPORARY POWER MAY BE CONNECTED BY UTILITY COMPANY 2.0'C <br /> NECESSARY TO AVOID CONFLICTS. SOURCES OR PORTABLE GENERATOR.PORTABLE GENERATORS SHALL IRRIG IRRIGATION SYSTEM CONTROLLER 30.3 CONDUIT IN SIZE SHOW WITH MULTIPLE FEEDERS AS INDICTED <br /> BE PROVIDED WITH CRITICAL SILENCERS FOR SOUND ATTENUATION. ( 30.3 <br /> 9. CONDUCTORS SHALL BE LABELED IN JUNCTION BOXES AND AT 2-20-C CONDUIT IN OVANTITYSIZE SHOWN WITH MULTIPLE FEEDERS <br /> TERMINATIONS. Ti. IDENTIFIED SRTHE LIMITS OFYSTEM COMPONENTS WORK.LIMITS IDENTIFIED IN OTHER SECTIONS THIN THE BOUNDARY SWR SECURITY/CCN SYSTEM CONTROLLER ® ASINDICTED.ROUTE CIRMAIfi AS REQUIRED.REFER 10 PIANS SITE ELECTRICAL EQUIPMENT-EXISTING(SURVEY) SITE ELECTRICAL <br /> AND DETAILS FOR INFORMATION <br /> 10. COORDINATE INSTALLATION WITH SERVING UTILITIES:SNOHOMISH PUD, OF THIS CONTRACT APPLY.RESTORE FINAL GRADES AND FINISHES,AS SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br /> FRONTIER COMMUNICATIONS,COMCAST COMMUNICATIONS,AND WAVE REQUIRED BY APPLICABLE SPECIFICATION SECTIONS,WHEN THE FA FIRE ALARM CONTROLLER 812.BEL-1 FIXTURE TAG:FIXTURE TYPE PANEL-CIRCUIT <br /> COMMUNICATIONS.PROVIDE INFRASTRUCTURE IN COMPLIANCE WITH BOUNDARIES OF THE ELECTRICAL WORK ARE OUTSIDE THE AREAS DEFINED e812 <br /> 1 FIXTURE TAG:FIXTURE TYPE --1e=1 UTILITY POLE WITH ARM ID 4'x4'x3'D VAULT WITH STEEL UD <br /> EACH UTILITY COMPANY'S CURRENT HANDBOOK,STANDARDS,AND BY OTHER DISCIPLINES. c-b-c PANEL-CIRCUIT C=COMMUNICATIONS POE/COMCAST/WAVE <br /> POLICIES.THIS SCOPE OF WORK INCLUDES ITEMS IDENTIFIED-BY EACH I----1 UNDERGROUND VAULTc UNDERGROUND PULL BOX/MANHOLE E=PORT ELECIRICAL/LIGHTING <br /> UTILITY COMPANY-AS OWNER PROVIDED.PROVIDE AS INDICATED ON L---J (SEE DESCRIPTION UNDER SITE SYMBOLS) DIT POLE TAC AREA/POLE NUMBER MISS =SYSTEM P=POWER:PUD POWER <br /> AA1-11 POLE TYPE FH=RSHERMANS HARBOR I' a COM- COMMUNICATIONS <br /> DRAWINGS FOR CASES WHERE THE WORK SHOWN EXCEEDS MINIMUM BEN-1 PANEL-CIRCUIT ES=ESPLANADE D- DATA O 30'x30"x24'0 VAULT WITH STEEL UD NOTE: PROVIDE <br /> UTILITY COMPANY REQUIREMENTS. <br /> E- PORT ELECTRICAL C=COMMUNICATIONS POE/COMCAST/WAVE VAULT TYPE AS <br /> (NOTE:SEE'UNDERGROUND PULL BOX/MANHOLE'FOR SYSTEM P- PUD HV POWER E=PORT ELECTRICAL/LIGHTING SHOWN ON DWGS. <br /> ATEL- TELEPHONE <br /> ABBREVIATIONS) <br /> CBL- CABLE 0 12x18 ELECTRICAL HANDHOLE,STEEL <br /> TX- UTILITY TRANSFORMER VAULT GALV.COVER,OPEN BOTTOM, <br /> • LEGENDS SHOWN ON INDIVIDUAL SHEETS TAKEFO- FIBER OPTIC PEDESTRIAN RATED <br /> h=PROJECT ZONE LOCATION <br /> PRECEDENCE OVER THIS LEGEND.NOT ALL SYMBOLS c=NUMBER II T I FRONTIER-3S WITH 013L-STEEL US <br /> LISTED ARE USED. T=TELEPHONE <br /> Lg HANOHOLE-STREET LIGHTING, J <br /> TREE LIGHTING AND BRANCH (-"� <br /> CIRCUIT SITE HIRING I I 'J PUD PRIMARY SWITCH CABINET <br /> ABBREVIATIONS 0 POWER PEDESTAL <br /> I " I PUD PRIMARY PULL VAULT <br /> A,AMP AMPERES EMT ELECTRICAL METAWC TUBING LCP LIGHT CONTROL PANEL PNL PANEL <br /> AF AMPERE(RATED)FUSES ENCL ENCLOSURE MAX MAXIMUM POE PORT OF EVERETT r---,,-] PUD PAD MOUNTED UTILITY TRANSFORMER <br /> AFF ABOVE FINISHED FLOOR EOL END OF LINE MCA MINIMUM CIRCUIT AMPERES +,POS POSITIVE (LESS THAT 750KVA,SHOW ON DRAWINGS) <br /> AFG ABOVE FINISHED GRADE EPA EFFECTIVE PROJECTED AREA MFR MANUFACTURER PRI PRIMARY <br /> AL ALUMINUM(ALLOY) ESPL. ESPLANADE MIN MINIMUM PUD PUBUC UTIUTY DISTRICT <br /> ALC AUTOMATED LIGHTING CONTROL EUC ELECTRICAL UTILITY CENTER MISC MISCELLANEOUS REOD REQUIRED CLEAR ZONE/WARD POST CENTERLINE <br /> AS AMPERE(RATED)SWITCH EWC ELECTRIC WATER COOLER MLO MAIN LUGS ONLY RNC RIGID NONMETALLIC CONDUIT <br /> MTD MOUNTED (PVC) I9 SITE ELECTRICAL EQUIPMENT <br /> ATS AUTOMATIC TRANSFER SWITCH FELECTRICWATER HEATER -- W/CLEAR ZONE SHOW <br /> AUTO AUTOMATIC FAA • FIRERE ALARM MOB MARINE OPERATIONS BUILDING RR REMOVE AND REPLACE <br /> AUX AUXILIARY FAA FIRE ALARM ANNUNIATOR MTR MOTOR SEC SECONDARY <br /> AWG AMERICAN WIRE GAUGE FC FOOT CANDLES -N- NEUTRAL(GROUNDED CONDUCTOR) SNOPUD SNOHOMISH COUNTY PUD O ELECTRICAL EQUIPMENT AS NOTED <br /> BAT BATTERY FLA FULL LOAD AMPERES NC NORMALLY CLOSED SPOT SINGLE POLE DOUBLE THROW O PUD ELECTRICAL METER <br /> -,NEG NEGATIVE SURF SURFACE ® <br /> BFG BELOW FINISHED GRADE FLEX FLEXIBLE NEC NATIONAL ELECTRICAL CODE SPST SINGLE POLE SINGLE THROW <br /> C CONDUIT(CIRCULAR RACEWAY) FTB FLUIDIZED THERMAL BACKFILL SWBD SWITCHBOARD LANDSCAPE UGHTNG GFCI RECEPTACLE <br /> CAB CABINET FU FUSE NEMA NATIONAL ELECTRICAL SWGR SWITCHGEAR WITH WEATHERPROOF-IN-USE COVER, <br /> CB CIRCUIT BREAKER GEN GENERATOR MANUFACTURE'S ASSOC. TB TERMINAL BOARD POST MOUNTED <br /> CFM CUBIC FEET PER MINUTE EFl GROUND FAULT CIRCUIT NIC NOT IN CONTRACT TC TIMECLOCK <br /> CKT CIRCUIT INTERRUPTER NL NIGHT LIGHT(UNSWITCHED) TEL TELEPHONE 1� <br /> CLG CDUNG GND GROUND NO NORMALLY OPEN TYP TYPICAL IkA LIGHTING AND POWER PEDESTAL <br /> CO CONDUIT ONLY CRC GALVANIZED RIGID STEEL CONDUIT NTS NOT TO SCALE UL UNDERWRITERS LAB CONDUIT RACEWAY <br /> CT CURRENT TRANSFORMER CRD IN-GROUND OC ON CENTER UON UNLESS OTHERWISE NOTED <br /> CU COPPER HP HORSEPOWER OD OUTSIDE DIAMETER V VOLS <br /> ---- UNDERGROUND CONDUIT <br /> DC DIRECT CURRENT HZ HERTZ(CYCLES PER SECOND) OFCI OWNER FURNISHED CONTRACTOR VA VOLT-AMPERES <br /> DISC DISCONNECT IES ILLUMINATING ENGINEERING SOCIETY INSTALLED VFD VARIABLE FREQUENCY DRIVE ---- CONDUIT UNE WEIGHT' <br /> DIA DIAMETER ID INSIDE DIAMETER OF01 OWNER FURNISHED,OWNER W WAS <br /> DIV DIVISION IG ISOLATED GROUND INSTALLED WITH CONDUIT EXISTING LINE WIEGHT <br /> DP DISTRIBUTION PANEL IN INCANDESCENT OS OCCUPANCY SENSOR W/0 WITHOUT E-- CONDUIT STUB OUT <br /> DPDT DOUBLE POLE DOUBLE THROW IMC INTERMEDIATE METAL CONDUIT P POLE WP WEATHERPROOF <br /> DPST DOUBLE POLE SINGLE THROW K KEY OPERATED PB PUSH-BUTTON XFMR TRANSFORMER O CONDUIT STUB UP/DOWN <br /> DWG DRAWING KCM THOUSAND CIRCULAR MILS PEND PENDANT ',IN INCHES - - -- <br /> EXIST EXISTING KO KNOCK OUT PH PHASE ',FT FEET <br /> EF EXHAUST FAN KW KILOWATTS PLP POWER/UGHTING PEDESTAL 0 PHASE / <br /> KVA KILO VOLT-AMPERES �• APPROXIMATE (S( <br /> PROJECT ENGINEER: SCALE: PORT OF EVERETT <br /> DWG. NO;�ATT/y� <br /> y0 j D E. DAVID NONE 0).00 <br /> 1 Port Of nwPoIINHAvenue s.s�re.A wDFit4ie DESIGNED BY: DATE: SEINER WHARF SEGMENT D & <br /> Es! is u r” SexTTIe,Washington 98134 C HARBOR POWER JRC/EJD JUNE 13 2016 CIP NO. 2-0-023-01, <br /> 0 5 012-0-044 Ot <br /> �/. 1'hwe:S1G-L?41387 `� Ir. DRAWN BY: CHECKED BY: PACIFIC RIM PLAZA PLATFORM <br /> �`�. EVERETT I`ex'1cc 13R8 ` iV J. CAMPBELL CH DAVID <br /> /' ENGINEERS,INC. mom, „JeR�,ee�,ca � ISSUED FOR BID AND 1 z"Yom° PROJECT MR-CM-2016-06 <br /> r P.D.BDX s3a /U\6/10/16 EJD �. ;= APPROVED BY: ELECTRICAL SYMBOLS AND D <br /> EVERETT,WA 98206 CONSTRUCTION <br /> (425)259-3164 PROJECT N O T E S <br /> No. HPE PROJECT NUMBER:2015-001.05 <br /> SHEET NO. 56 OF 71 <br />