Laserfiche WebLink
NVL Laboratories, Inc. INVIL <br /> 4703 Aurora Ave N.Seattle,WA 98303 <br /> p 206.54?.0100 I :06 634a936 www nvilabs crm LABS <br /> Bulk Asbestos Fibers Analysis <br /> By Polarized Light Microscopy <br /> Client: NVL Field Services Division Batch#: 1715847,00 <br /> Address:4708 Aurora Ave.N. Client Project#:2017-0728 <br /> Seattle,WA 98103 - Date Received: 9/5/2017 <br /> Samples Received:9 <br /> Attention: Mr.Tanveer Khan Samples Analyzed: 9 <br /> Project Location: 1111 34th St. Everett,WA 98201 Method: EPA/600/R-93/116 <br /> &EPA/600/M4-82-020 <br /> Layer 5 of 5 Description: Black asphaltic fibrous material <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type:% <br /> Asphalt/Binder, Fine grains Cellulose 79% None Detected ND <br /> Lab ID: 17087047 Client Sample#: 2017-0728-3-5 <br /> Location: 1111 34th St. Everett,WA 98201 <br /> Layer 1 of 5 Description: Beige tile <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Binder/Filler,Mineral grains Cellulose 2% None Detected ND <br /> Layer 2 of 5 Description: Black asphaltic mastic <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type:% <br /> Asphalt/Binder, Fine grains Cellulose 4% None Detected ND <br /> Layer 3 of 5 Description: Brown tile <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Binder/Filler, Mineral grains None Detected ND None Detected ND <br /> Layer 4 of 5 Description: Black asphaltic mastic <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Asphalt/Binder, Fine grains Cellulose 2% None Detected ND <br /> Layer 5 of 5 Description: Black asphaltic fibrous material <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Asphalt/Binder, Fine grains Cellulose 82% None Detected ND <br /> Lab ID: 17087048 Client Sample#: 2017-0728-3-6 <br /> Location: 1111 34th St. Everett,WA 98201 <br /> Layer 1 of 1 Description: Gray sandy material with paint <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Binder/Filler, Granules Spider silk <1% None Detected ND <br /> Sampled by: Client <br /> Analyzed by: Peter Murphy Date:09/06/2017 <br /> Reviewed by: Nick Ly Date:09/07/2017 Nick Ly,Technical Director <br /> Note: If samples are not homogeneous,then subsamples of the components were analyzed separately.Ail bulk samples are analyzed using both EPA <br /> 6001R-93/116 and 6001M4-82-020 Methods with the following measurement uncertainties for the reported%Asbestos(1%=0-3%,5%=1-9%,10%=5-15%, <br /> 20%=10-30%,50%--.40-60%y This report relates only to the items tested. If sample was not collected by NVL personnel,then the accuracy of the results is <br /> limited by the methodology and acuity of the sample collector. This report shall not be reproduced except infull, without written approval of NVL <br /> Laboratories,Inc. It shall not be used to claim product endorsement by.NVLAP or any other agency of the US Government <br /> page r /7 3.3 <br />