My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3313 OAKES AVE A B 2020-07-14
>
Address Records
>
OAKES AVE
>
3313
>
3313 OAKES AVE A B 2020-07-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2020 2:36:45 PM
Creation date
7/14/2020 2:35:06 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3313
Unit
A B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Component Performati.ce Path, pg. 2 - ENV-UA <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Pods Tenant Improvement Date 06/23/2017 <br /> Fenestration Area as%gross above-grade wall area Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0% <br /> Building Component Proposed UA Target UA <br /> Ins.R I Plan/Detail#I F-factor Source&Table#8 F-factor' x Perimeter I=UA(U x A) F-factor x Perimeter= UA(U x A) <br /> a) R= I Perimeter with no insulation 0.730 550 401.5 0.540 550 297.0 <br /> 0 <br /> m L R= Slab-On-Grade F-0.54 <br /> o, R_ <br /> IS 6' R=0 .550 <br /> a)1-6 <br /> R= <br /> Heated Slab-On-Grade F-0.55 <br /> I R= <br /> Schedule ID IU-factor Sources'° U-factor x Area(A) =UA(U x A; U-factor x Area(A)= UA(U x A) <br /> IMan doors 0.370 I 84 31.1 0.37 84 I 31.1 <br /> CD <br /> o, Opaque Swing Doors U-0.37 <br /> '6 <br /> 0 <br /> o I9'x10'roll-ups 0.063 630 39.7 0.34 1 1030 I 350.2 <br /> iii <br /> L 20'x20'roll-up 0.063 400 25.2 Opaque rollup&sliding U-0.34 <br /> O I <br /> ro 0.30 <br /> t Non-Metal Frame U-0.30 <br /> C <br /> Z <br /> Storefront fixed 0.40 1841 1 736.4 0.38 1841 699.6 <br /> c 4= Metal Frame, Fixed U-0.38 <br /> o <br /> Q) <br /> 'a2 I I <br /> 0 <br /> uon 0.40 <br /> To Metal Frame,Operable U-0.40 <br /> -iii <br /> a <br /> I I <br /> o <br /> I I <br /> °i Storefront entry 0.68 42 28.6 0.60 42 ' 25.2 <br /> m I I Metal Entrance Door U-0.60 <br /> 2 <br /> Skyco-Skypro IR Illuminator 0.30 480 144.0 0.50 480 240.0 <br /> T All types U-0.50 <br /> o� i <br /> c Q <br /> Area' UA Areal UA <br /> Page 2 Subtotal 4027 1406 4027 1643 <br /> TO COMPLY-The Proposed Total UA shall not Page 1 Subtotal 51281 2650 51281 2499 <br /> exceed the Target Total UA. Project Total 55308 4056 55308 4142 <br /> Component Performance Compliance (UA) UA COMPLIES <br /> Note 1-If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1,then Target Area Adjustment of all applicable envelope <br /> elements will be calculated automatically by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> Note 2-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 3-Proposed CMU mass wall in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target U-value of 0.014 <br /> Note 4-For semi-heated spaces utilizing the wall insulation exception,enter Target Wall U-factors under Proposed Wall U-factors so exterior <br /> walls are neutral to the calculation. <br /> Note 5-Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br /> Note 6-Demising walls,doors,and vertical fenestration separating spaces with different degrees of space conditioning(unconditioned,semi-heated, <br /> fully conditioned)shall be included only on the ENV-UA form for the space with the greatest degree of space conditioning. <br /> Note 7-List Group R above grade mass walls here. List all other mass walls,Commercial and Group R,in the Opaque Walls-Above Grade section. <br /> Note 8 -Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 9 Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 10-Fenestration assembly U-Factors shall be the manufacturer's NFRC product rating, which includes the glazing and frame,or shall be; <br /> the default value per Section C303.1.3. <br />
The URL can be used to link to this page
Your browser does not support the video tag.