Laserfiche WebLink
No.5—Catch Basins <br /> Maintenance Defect Conditions When Maintenance is Needed Results Expected When <br /> Component Maintenance is performed <br /> Ladder Ladder Rungs Ladder is unsafe due to missing rungs, Ladder meets design <br /> Unsafe cracked/broken rungs,rungs not securely attached standards and allows <br /> to basin wall,misalignment,rust,cracks,or sharp maintenance person safe <br /> edges. access. <br /> Metal Grates Trash and Trash and debris that is blocking more than 20% Grate free of trash and <br /> (If Applicable) Debris of grate surface inletting capacity. debris. <br /> Damaged or Grate missing or broken member(s)of the grate. Grate is in place and meets <br /> Missing. design standards. <br /> No. 21 - Conveyance Storm Pipes <br /> Drainage System Potential Conditions When Maintenance Is Results Expected When Maintenance <br /> Feature Defect Needed Is Performed Or Not Needed <br /> General Obstructions, Root enters or deforms pipe,reducing Use mechanical methods to remove root <br /> Including Roots flow. if possible.Use of chemicals to remove <br /> roots shall be done in accordance with an <br /> Integrated Pest Management plan. If <br /> necessary,remove the vegetation over the <br /> line. <br /> Pipe Dented or Inlet/outlet piping damaged or broken Pipe repaired and/or replaced. <br /> Broken and in need of repair. <br /> Pipe Rusted or Any part of the piping that is crushed Pipe repaired and/or replaced. <br /> Deteriorated or deformed more than 20%or any <br /> other failure to the piping. <br /> Sediment& Sediment depth is greater than 20%of Install upstream debris traps(where <br /> Debris pipe diameter. applicable)then clean pipe and remove <br /> material. <br /> Debris barrier or A debris barrier or trash rack that had Debris barrier or trash rack is replaced. <br /> Trash Rack been installed on the end of a drainage <br /> Missing pipe is missing <br /> Joint/Seal The joint between pipe sections is The joint and/or seal is repaired so that <br /> Problems separated and/or the seal at the joint is joint is not separated and is properly <br /> cracked or broken. sealed. <br /> No. 22 - Facility Discharge Points <br /> Drainage System Potential Conditions When Maintenance IsResults Expected When Maintenance <br /> Feature Defect Needed J Is Performed Or Not Needed <br /> Monitoring Inspection of Sheen,obvious oil or other Identify and eliminate pollution source <br /> Discharge Water Contaminants present. AND report discharge to The City of <br /> for Obvious Everett Surface Water Management <br /> Signs of Poor Division. <br /> Water Quality. <br /> Effluent discharge from facility should be <br /> clear. <br /> Receiving Area Water in receiving area is causing Receiving area sound. <br /> Saturated substrate to become saturated and <br /> unstable. <br /> Pinehurst Ave. Duplex <br /> Drainage Report <br />