My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2219 PINEHURST AVE BASE FILE 2020-07-14
>
Address Records
>
PINEHURST AVE
>
2219
>
BASE FILE
>
2219 PINEHURST AVE BASE FILE 2020-07-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2020 4:05:40 PM
Creation date
7/14/2020 4:03:31 PM
Metadata
Fields
Template:
Address Document
Street Name
PINEHURST AVE
Street Number
2219
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Stormwater Pollution Prevention Plan <br /> 3.1.3 Element#3 — Control Flow Rates <br /> In order to protect the properties and waterways downstream of the project site, stormwater <br /> discharges from the site will be controlled. The specific BMPs for flow control that shall be used <br /> on this project include: <br /> • The construction and use of the proposed silt fences and infiltration trenches. <br /> • Temporary sediment facility (BMP C241) <br /> Temporary sedimentation facilities will be provided on the site during infiltration trench and <br /> raingarden construction to assure flow rates are controlled. Once the infiltration trenches and <br /> raingarden are constructed and operational, flows will be routed to both facilities.11 <br /> Alternate flow control BMPs are included in Appendix C as a quick reference tool for the onsite <br /> inspector in the event the BMP(s) listed above are deemed ineffective or inappropriate during <br /> construction to satisfy the requirements set forth in the General NPDES Permit (Appendix D). <br /> To avoid potential erosion and sediment control issues that may cause a violation(s) of the <br /> NPDES Construction Stormwater permit (as provided in Appendix D), the Certified Erosion and <br /> Sediment Control Lead will promptly initiate the implementation of one or more of the alternative <br /> BMPs listed in Appendix C after the first sign that existing BMPs are ineffective or failing. <br /> The project site is located west of the Cascade Mountain Crest. As such, the project must <br /> comply with Minimum Requirement 7 (Ecology 2005). <br /> In general, discharge rates of stormwater from the site will be controlled where increases in <br /> impervious area or soil compaction during construction could lead to downstream erosion, or <br /> where necessary to meet local agency stormwater discharge requirements (e.g. discharge to <br /> combined sewer systems). <br /> 3.1.4 Element#4— Install Sediment Controls <br /> All stormwater runoff from disturbed areas shall pass through an appropriate sediment removal <br /> BMP before leaving the construction site or prior to being discharged to an infiltration facility. <br /> The specific BMPs to be used for controlling sediment on this project include: <br /> • Silt Fence (BMP C233) <br /> • Materials on Hand (BMP C150) <br /> 7 <br />