Laserfiche WebLink
Oe5 $r.__.., 6 /A1 KELP /,tt, -16Y- ce4- 4)40c..S0N RCN Tec7" <br /> `1110) <br /> ENGINEERING <br /> ab, <br /> ti <br /> PUBLIC SERVICES DEPARTMENT <br /> January 26, 2018 • <br /> 3 9 <br /> Land Liaison n <br /> PO Box 266 :s d2 2,2:0F <br /> Snohomish WA 98291 c. ,'°, - s�, .,_ <br /> / uc ¢r f __ <br /> RE: Owner: Reykdal <br /> Job Address: 7109 Rainier Drive <br /> Plan Check Number: C1712-004, C1712-005, C1712-006 &C1712-007 <br /> Ms. Albert, <br /> In response to your application for a construction permit, your plans have been examined and you <br /> are advised that the issuance of a permit is being withheld for the reasons listed below. These <br /> comments address building issues only. Additional revisions or additions may be required by other <br /> departments such as Utilities, Planning or Fire. All references refer to the 2015 International <br /> Building Code (IBC), 2015 International Residential Code (IRC), as amended by the State of <br /> Washington and/or Washington State Energy Code (WSEC) 2015 Edition, as adopted by the City of <br /> Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested. <br /> Construction documents shall be of sufficient clarity to indicate the location, nature and extent of <br /> the work proposed and show in detail that it will conform to the provisions of the building code <br /> and relevant laws, ordinances, rules and regulations. <br /> ARCHITECTURAL&ENERGY CODE REVIEW <br /> 1. The installation of the water heater and the furnace in the garage would eliminate one of <br /> the required parking spaces in the garage. Provide minimum two spaces not less than 8.5' <br /> x 18.5'in the garage. see G - `PO FLR, MAP 014 Sacs,. .3 Co <br /> 2. Detail"F"on sheet 3 shows rigid insulation between the garage and the conditioned space <br /> going down approximately 4 inches and then turning 90'degrees to go under the slab. Rigid <br /> insulationis required to go down for a minimum depth of 24 inches when installed at the <br /> perimeter of a slab-on-grade located in a conditioned spaces The transition from section H <br /> to section F does not meet the intent of the energy code. 4e a 4.4 448' To OYES Q 40 <br /> ON SMT 3 'f (.At.t.O4J1 14004D 'CO PDN. .pLAN 01.4 -SHTS• 3 lv' <br /> 3. Sheet 3 references an"alternate entry for west most dwellings - shown Sht. 7". The details <br /> on both sheets are the same. Please clarify (and correct sheet number). bee. DETAIL-6 <br /> GAI.A.Ep DIT ON P1,Iz..t't.ANS ON 6I4T. . Si4t 4 7 <br /> 4. Provide detail of the connection of the concrete porch at the entry to the foundation, <br /> capable of resisting differential settling. See on.® ADD ®is SNT 8 s1/eA <br /> ArMe D TO" F:13.4.1.PL IJ ®N 31416. 3tlot t 7 Page 1 ofy5' <br /> CITY OF EVERETT• 3200 Cedar Street • Everett,WA 98201 • (425)257-8810 • Fax(425) 257-8 <br />