Laserfiche WebLink
Glu-Lam 24F-V4: Fb=2,400, Fv=265(>165used), Fcl 650, Fc=1,650, & E= <br /> 1,600,000 <br /> The above wood stress values are from 2015 NDS Table 4A. <br /> The following are from TrusJoist McMillan: <br /> LVL (microllam): Fb=2,600, Fv=285, Fc1=750, Fc=2,510, & E=1,900,000 <br /> PSL (parallam): Fb=2,900, Fv=290, Fc=750, Fc=2,900, & E=2,000,000 <br /> Page 2 <br /> S _5 <br />