My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7109 RAINIER DR G H 2020-07-15
>
Address Records
>
RAINIER DR
>
7109
>
7109 RAINIER DR G H 2020-07-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 9:05:23 AM
Creation date
7/15/2020 9:04:21 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER DR
Street Number
7109
Unit
G H
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Reykdal 1380-2 <br /> Heating System Type: 0411 Other Systems CHeat Pump <br /> To see detailed instructions for each section,place your cursor on the word"instructions". <br /> Design Temperature <br /> j <br /> Design Temperature Difference(AT) 49 <br /> Everett AI`B <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Conditioned Floor Area(sq ft) 1,380 <br /> Average Ceiling Height Conditioned Volume <br /> Average Ceiling Height(ft) 8.7 12,006 <br /> Glazing and Doors U-Factor X Area = UA <br /> 11-0 30 . 0.300 257 76.98 <br /> Skylights U-Factor X Area = UA <br /> 0.50 4 2.00 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> R49_ 0.026 694 18-04 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Select R Value v} No selection <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> �R 21 Intermediate v 0.056 2,190 122.63 <br /> Floors U-Factor X Area 0-30 <br /> V 0.029 548 15.89 <br /> is <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Select R-value . No selection --- <br /> Slab Below Grade(see Figure 1) F-Factor X Len UA <br /> Select condiU r in ••• No selection <br /> � <br /> Slab on Grade(see Figure 1) F-Factor X Len r th UA <br /> CR-10 Perimeter v l J 0.540 50 27.00 <br /> Location of Ducts <br /> Duct Leakage Coefficient <br /> Unconrll tinned Space v lI <br /> 1.10 <br /> Sum of UA 262.54 <br /> Envelope Heat Load 12,865 Btu 1 Hour <br /> Figure 1. sum of uAX AT <br /> •. Air Leakage Heat Load 6,354 Btu/Hour <br /> Volume X 0.6 X AT X.018 <br /> Above Grade l Building Design Heat Load 19,218 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 21,140 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 29,596 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Fumace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.