Laserfiche WebLink
• <br /> MasterSure Z 60 Technical Data Sheet <br /> Performance Characteristics Product Notes <br /> The data in the following graph represents the slump and Corrosivity – Non-Chloride, Non-Corrosive: MasterSure Z 60 <br /> workability performance that can be achieved through the admixture will neither initiate nor promote corrosion of <br /> use of MasterSure Z 60 admixture. The four mixtures were reinforcing steel embedded in concrete, prestressing steel or <br /> evaluated at a concrete temperature of 90°F(32 °C).The first of galvanized steel floor and roof systems. Neither calcium <br /> mixture utilized a high-range water reducer (HRWR) without chloride nor other chloride-based ingredients are used in the <br /> MasterSure Z 60 admixture. The three remaining mixtures manufacture of MasterSure Z 60 admixture. <br /> utilized the same high-range water reducer with a low,medium Compatibility: MasterSure Z 60 admixture is compatible with <br /> and high dosage of the MasterSure Z 60 admixture. These most admixtures used in the production of quality concrete, <br /> mixtures had 600 lb/yd3 (356 kg/m3) of cement and a water- including normal, mid-range and high-range water-reducing <br /> cement ratio(w/c)of 0.40. admixtures, air-entrainers, accelerators, retarders, extended <br /> 120% set control admixtures, corrosion inhibitors, and shrinkage <br /> 1 reducers. <br /> ,00% —-- <br /> Do not use MasterSure Z 60 admixture with admixtures containing <br /> 80% beta-naphthalene sulfonate.Erratic behaviors in slump,workability <br /> retention and pumpability may be experienced. <br /> cc 60% <br /> MasterSure Z 60 admixture has only been tested with admixtures <br /> 40% manufactured by BASF. As a result, use of MasterSure Z 60 <br /> +HRWR admixture with non-BASF admixtures may produce unpredictable <br /> 20%— HRWR+Low Dosage <br /> �HRWR,Mad;�mDosaga results. BASF denies any warranty expressed or implied with <br /> HRWR+High Dosage respect to any application using a non-BASF admixture in <br /> 0% <br /> 0 20 40 E0 80 combination with the use of MasterSure Z 60 admixture. <br /> Time(minutes) <br /> Storage and Handling <br /> Guidelines for Use Storage Temperature:MasterSureZ 60 admixture must be stored <br /> Dosage: MasterSure Z 60 admixture has a recommended at temperatures above 40°F(5°C).If MasterSure Z 60 admixture <br /> dosage range of 2 to 12 fl oz/cwt (130 to 780 mL/100 kg) freezes,thaw and reconstitute by mechanical agitation. Do not <br /> of cementitious materials. Because of variations in concrete use pressurized air for agitation. <br /> materials, jobsite conditions and/or applications, dosages Shelf Life: MasterSure Z 60 admixture has a minimum shelf life <br /> outside of the recommended range may be required. In such of 12 months. Depending on storage conditions, the shelf life <br /> cases, contact your local sales representative. may be greater than stated. <br /> Mixing: MasterSure Z 60 admixture can be added with the <br /> initial batch water or as a delayed addition. <br /> BASF Corporation <br /> www.master-builders-solutions.basf.us page 2 of 3 <br />