My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3531 NORTON AVE 2019 Plans 2022-11-04
>
Address Records
>
NORTON AVE
>
3531
>
Plans
>
3531 NORTON AVE 2019 Plans 2022-11-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 1:01:43 PM
Creation date
7/27/2020 4:02:51 PM
Metadata
Fields
Template:
Address Document
Street Name
NORTON AVE
Street Number
3531
Permit
C1902-012
Year
2019
Notes
NEW DUPLEX
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size:2015 Washington State Windows and Doors <br /> Mechanical Ventilation 14 <br /> Prepared by: Dennis Smiley/Emerald Home Design Quantity Width Ft Width In Height Ft Height In Area R406 ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS V <br /> Windows 1 2 0 6 0 12.0 This Project Floor Area 1711 E <br /> Builder-Grand Ave LLC 2 2 0 4 0 16.0 Medium DwellingUnit (1500-5000 SF) requires 3.5point from table R406 This Project Number of Bedrooms 3 O <br /> E f <br /> Plan - 1711-0 1 4 0 4 0 16.0 q This Project Requires 60 CFM <br /> 5 4 0 5 0 100.0 This project g: V y <br /> Design Temp- 21 70- Design Temp= 49 3 3 0 6 0 54.0 p j t selects the following: <br /> Whole House Ventilation fresh air supply to be provided by exhaust fans (� <br /> 1 3 0 4 0 12.0 Z <br /> Conditioned Floor Area 1711 0 0 0 0 0 0.0 Table M1507.3.3(1) c J <br /> Average Ceiling Ht 9.93 0 0 0 0 0 0.0 EFFICIENT BUILDING ENVELOPE la: Continuous Whole House Mechanical Ventilation a <br /> Conditioned Volume 17859 0 0 0 0 0 0.0 Prescriptive compliance is based on Table R402.1.1 with the following modifications: N <br /> 0 0 0 0 0 0.0 Vertical fenestration U = 0.28 Fl Area 0-1 Bdrs 2-3 Bdrs 4-5 Bdrs 6-7 Bdrs >7 Bdrs Cl) <br /> Component U-Factor Area UA 0 0 0 0 of 0. 0 Floor R-38 <1500 30 45 60 75 90 N <br /> Glazing and Doors 0.280 300 83.9 0 0 0 0 0 0.0 Slab on grade R-10 perimeter and under entire slab 1501-3000 45 60 75 90 105 W <br /> Skylights 0.500 0 0.0 0 0 0 0 0 0.0 Below grade slab R-10 perimeter and under entire slab 3001-4500 60 75 90 105 120 Q <br /> Attic Area-R-38 0.027 0 0.0 0 0 0 0 0 0.0 or 4501-6000 75 90 105 120 135 <br /> (Attic Area - R-49 0.026 1096 28.5 0 0 0 0 0 0.0 Compliance based on Section R402.1.4: Reduce the Total UA by 5%. 6001-7500 90 105 120 135 150 <br /> Above Grade Walls - R-21 Int 0.056 2604 145.8 0 0 _ 0 0 0 0.0 >7500 105 120 135 150 165 CO <br /> Floors - R-38 0.025 1096 27.4 0 0 0 0 0 0.0 0.5CREDITS <br /> Below Grade Walls-R21 Interior 0.042 0 0.0 0 0r 0 0 0 0.0 Table M1507.3.3(2) <br /> Slab Below Grade-R-10 Fully Insulated 0.303 0 0.0 0 0 0 0 0 0.0 Runtime Percentage and Multiplying FactorZ <br /> Slab on Grade R-10 Fully Insulated 0.360 0 0.0 0 0 0 0 0 0.0 <br /> 0 0 0 0 0 0.0 HIGH EFFICIENCY HVAC EQUIPMENT 3a: 25% 33% 50% 66% 75% 100% (.9 <br /> Location of Ducts- Unconditioned Space 1.1 Duct Leakage Coefficient 0 0 0 0 0 0.0 ° 4 3 2 1.5 1.3 1 <br /> 210.0 Gas, propane or oil-fired furnace with minimum AFUE of 94%, orNims <br /> (/) <br /> Sum of UA 286 Glass Doors 1 6 0 8 0 48.0 Gas, propane or oiled-fired boiler with minimum AFUE of 92% <br /> Envelope Heat Load 13998 0 0 0 0 0 0.0 To qualify to claim this credit, the building permit drawings shall specify the option M1507.3.1 System design. The whole-house ventilation <br /> -Air Leakage Heat Load 9451 0 0 0 0 0 0.0 being selected and shall specify the heating equipment type and the minimum system shall consist of one or more supply or exhaust fans, Lii <br /> equipment efficienc . or a combination of such, and associated ducts and controls. <br /> Building Design Heat Load 23449 0 0 0 0 0 0.0 y <br /> Add BuildingDuct Heat Load (x 1.1) 25794 Local exhaust or supply fans are permitted to serve CI <br /> 0 0 0 0 0� 0.0 1.0 CREDITS <br /> Maximum Heat Equipment Output (x 1.4) 36111 48.0 as such a system. Outdoor air ducts connected to the return <br /> Non-Glass Doors 1 3 0 8 0 24.0 side of an air handler shall be considered as providing sup-ply <br /> TABLE R402.1.1 1 2 8 6 81 17.8 ventilation. QUJ <br /> INSULATION AND FENESTRATION REQUIREMENT BY COMPONENT(a) 0 0 0 0 0 0.0 EFFICIENT WATER HEATING 5a: ,J <br /> __ thehouseshall berated 1.75 0 0 0 0 0 0.0 All showerhead and kitchen sink faucets installed in atM1507.3.2 System controls. The whole-house mechanical <br /> FENESTRATION U-FACTOR(b) 0.28 0 0 0 0 0[ 0.0 <br /> ventilation system shall be provided with controls that <br /> SKYLIGHT(b) U-FACTOR _ 0.5 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less. O <br /> 41.8 enable manual override. W <br /> GLAZED FENESTRATION SHGC(b,e) NR Overhead Glazing 0 0 0 0 0 0.0 O C <br /> CEILING R-VALUE (k) 49 0 0 0 0 0 0.0 To qualify to claim this credit, the building permit drawings shall specify the option M1507.3.3 Mechanical ventilation rate. The whole-house c <br /> (g,m.n) R-VALUE 21 INT 0 0 0 0 0 0.0 being selected and shall specify the maximum flow rates for all showerheads, kitchen mechanical ventilation system shall provide outdoor W <br /> WOOD FRAM WALL sink faucets, and other lavatory faucets. <br /> MASS WALL R-VALUE (i) 21/21 0 0 0 0 0 0.0 air at a continuous rate of not less than that determined in <br /> FLOOR R-VALUE 38 0 0 0 0 0 0.0 0.5 CREDITS accordance with Table M1507.3.3(1). <br /> BELOW GRADE (c,m) WALL R-VALUE 21 INT+TB 0.0 <br /> SLAB (d) R-VALUE AND DEPTH 10, 2 FT Exception: The whole-house mechanical ventilation <br /> system is permitted to operate intermittently where the <br /> system has controls that enable operation for not less <br /> For SI: 1 foot = 304.8 mm, ci = continuous insulation, int = intermediate framing. EFFICIENT WATER HEATING 5c: than 25-percent of each 4-hour segment and the ventilation <br /> Water heating system shall include one of the following: rate prescribed in Table M1507.3.3(1) is multiplied <br /> (a) R-values are minimums. U-factors and SHGC are maximums. When Gas, propane or oil water heater with a minimum EF of 0.91 by the factor determined in accordance with Table M1507.3.3(2). <br /> insulation is installed in a cavity which is less than the label or design thickness of or <br /> the insulation, the compressed R-value of the insulation from Appendix Table Solar water heating supplementing a minimum standard water heater. Solar water <br /> A101.4 shall not be less than the R-value specified in the table. heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the <br /> Solar Rating and Certification Corporation (SRCC) Annual Performance of OG-300 • <br /> (b) The fenestration U-factor column excludes skylights. The SHGC column Certified Solar Water Heating Systems. <br /> applies to all glazed fenestration. or <br /> Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards <br /> (c) "10/15/21 +TB" means R-10 continuous insulation on the exterior of the wall, of <br /> or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation NEEA's Northern Climate Specifications for Heat Pump Water Heaters. <br /> plus a thermal break between the slab and the basement wall at the interior of To qualify to claim this credit, the building permit drawings shall specify the option <br /> the basement wall. "10/15/21 +TB" shall be permitted to be met with R-13 cavity being selected and shall specify the water heater equipment type and the minimum <br /> insulation on the interior of the basement wall plus R-5 continuous insulation on equipment efficiency and, for solar water heating systems, the calculation of the <br /> the interior or exterior of the wall. "TB" means thermal break between floor slab minimum energy savings. <br /> and basement wall. <br /> 1.5 CREDITS <br /> (d) R-10 continuous insulation is required under heated slab on grade floors. See <br /> R402.2.9.1. <br /> (e) There are no SHGC requirements in the Marine Zone. a. Projects using this option may not use Option la, 1 b or lc. <br /> (i) The second R-value applies when more than half the insulation is on the b. Projects may only include credit from one space heating option, 3a, 3b, 3c or 3d. When <br /> interior of the mass wall. a housing unit has two pieces of equipment (i.e., two furnaces) both must meet the <br /> standard to receive the credit. <br /> (k) For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R- <br /> 38. c. Plumbing Fixtures Flow Ratings. Low flow plumbing fixtures (water closets and urinals) <br /> and fittings (faucets and showerheads) shall comply with the following requirements: <br /> (m) Int. (intermediate framing) denotes standard framing 16 inches on center with <br /> headers insulated with a minimum of R-10 insulation. 1. Residential bathroom lavatory sink faucets: Maximum flow rate - 3.8 Umin (1.0 gal/min) <br /> when tested in accordance with ASME A112.18.1/CSA B125.1. <br /> (n) Log and solid timber walls with a minimum average thickness of 3.5 inches 2. Residential kitchen faucets: Maximum flow rate - 6.6 L/min (1.75 gal/min) when tested <br /> are exempt from this insulation requirement. in accordance with ASME A112.18.1/CSA B125.1. <br /> 3. Residential showerheads: Maximum flow rate - 6.6 L/min (1 .75 gal/min) when tested in <br /> accordance with ASME A112.18.1/CSA B125.1. <br /> V <br /> The following Washington State Energy Code information is required: J <br /> -J <br /> a. Post Energy Code Compliance Certificate within 3 ft. of electrical panel (these are available W <br /> at www.eneray.wsu.edu/code) <br /> b. Provide door blower test affidavit by final building inspection Q <br /> c. Provide (1) programmable thermostat 0 0 <br /> d. Provide duct sealing affidavit by final inspection Z <br /> e. A minimum of 75% of all interior lighting shall be high efficiency Q <br /> f. N. <br /> All required insulation and glazing values ti <br /> g. Building framing cavities shall not be used for ducts or plenums. Installation of ducts in r. <br /> exterior walls, floors, or ceilings shall not displace required envelope insulation. , , <br /> V <br /> W CI W <br /> -1O <br /> MIX <br /> 00 a <br /> DATE: <br /> 2/13/2019 <br /> EHD JOB: <br /> CITY OF EVERETT <br /> REVIEWED FOR PERMIT 2227 <br /> SHEET: <br /> 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.