Laserfiche WebLink
30'-0" <br /> 31 co <br /> 5-91�4 10-9/4 10.-111/2" 2-5/2� <br /> r. z <br /> O <br /> LANDINGS SHALL <br /> BE NO MORE THAN _ 30' 0" <br /> 7-3/4" BELOW Lu <br /> ce <br /> O_ _O O_ <br /> FINISHED FLOOR <br /> 1 2 3 ~ h <br /> 7 <br /> o- U U <br /> I 3020 I I 60610 SLIDER I 12040 I — 5040 _ 5040 I 12030 U Lu <br /> ' �'n SAFETY 1 ' 1 T w O O <br /> GLASS - all <br /> O N <br /> O <br /> N 7'-2' <br /> I.--1 w °' 4 <br /> I– , <br /> Q a) ' <br /> 10'-7" • 10'-9" o p t, o <br /> -.. _ -. <br /> .,„) <br /> 46' UO 0 3215- cC N <br /> o o) MASTER 30" FAN <br /> eg o KITCHEN <br /> \oo r BEDROOM DOOR r\ <br /> LIVING ROOM BEDROOM r 30" <br /> DOOR rn <br /> N 0o <br /> Z5) - Z <br /> 1\-- <br /> -7 ,- 1 SD qui <br /> PANTRY `v SD <br /> �O�G e CLOSET <br /> x5 '0 �� ''\r J ' <br /> I321 G Q <br /> FAN ��Q�' CLOSET <br /> II. - <br /> SD <br /> CMD DOOR DOOR 0In �o <br /> 0 19 O L 1_ <br /> SD - Q <br /> 3�0- FURN0 T M CMDIF Cr (Zj <br /> a <br /> o OO EFFICIENT WATER o -HANDRAIL in J C7 O <br /> �8K iv 30 3215 Z o c� <br /> .- o HEATER PER 5B Co <br /> N 20 MIN. TABLE R406.2 `�' o Co DOOR FAN = rn <br /> SOLID CORE/STEEL BOLLARD \ b 3215 9-8 h- W in Q Q <br /> W/SELF CLOSER FOR GAS APPLIANCES (T SEISMIC O 3._2.. �i' �? <br /> o STRAPS. \ / <br /> WHOLE �* ►� cA D Z w z <br /> t- U g <br /> in <br /> co ELEVATE IGNITION SOURCE <br /> PRESS. RELIEF W O F- Z o N - <br /> HOUSE— C O <br /> 18"A.F.F. IN GARAGE AND ; CLOSET co Q <br /> TO EXT. FAN r CAW Le) T m <br /> PROVIDE IMPACT \ / ATTIC 36" <br /> PROTECTION. ACCESS DOOR <br /> \ / <br /> I- 30" 10-1419 <br /> C <br /> HI LOW / CLOSET DOORSD tiSS �M'C�q�� <br /> COMBUSTION 30" %6"APA 24/6 RATED OSB '5 1 _ Gs'a <br /> AIR <br /> I \ / DOOR SHEATHING W/6d ©6"O.C. 4 ��' <br /> rn VENTILATION EDGE & 12" O.C. FIELD NAILING r <br /> BEDROOM , <br /> GARAGE OPEN/TO SD 4 0 (U.N.O. IN NOTES) 1P . w ' <br /> BE�OW @ `. R-49 �.x, E�6t`' <br /> Ea <br /> INSULATION SIONAL V.4) <br /> 4 INSULATION <br /> OVENTO BELOW ROOF TRUSS BAFFLE <br /> GARAGE O <br /> 1/2"GWB- WARM WALLS / \ PER FRAMING <br /> ` BEDROOM PLAN 7 <br /> SUPPORT MEMBERS / \ ^ � <br /> 5/8" GWB- TYPE X CEILING .-`\I 3 A <br /> cv �1 J U 4/-R-21 INSULATION <br /> / \ <br /> ' I/Alt <br /> 8'-7" 9.-8" 5/8" <br /> ® GWB H1 CLIP AT EACH TRUSS <br /> „ \ 4 TO DBL TOP PLATE/HEADER <br /> R- 16-0 GARAGE DOOR 5040 1 OR BEAM CONNECTION <br /> ENTRY I I \ <br /> I I mi 1.-0' <br /> ....„ <br /> // \ RIGID INSULATION <br /> EF, J ' J I 5040 I \ I 4040 I BEHIND HEADER(R-10) <br /> m o ' ' 2x6 STUDS / <br /> to oo @ 16" O.C. <br /> 12 <br /> 1050 I♦ 3._0.. <br /> ' 10'-672" 9'_6, 9'-1172" SHEAR WALL <br /> DOOR moi. ®-r• .► 344"T&G APA 24/6 RATED / PER PLAN <br /> SAFETY PLYWD SHEATHING GLUED \ <br /> GLASS &NAILED TO FLOOR JOISTS <br /> 10'-572" 19.-672" l <br /> 2x6 BASE PLATE <br /> (NAILING PER SHEAR R21 <br /> WALL SCHEDULE) i INSULATION <br /> LOWER FLOOR PLAN UPPER FLOOR PLAN / <br /> SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" A <br /> JOISTS VAPOR III <br /> PER PLAN BARRIERI. <br /> 2x6 BASE PLATE <br /> A (NAILING PER SHEAR �� <br /> WALL SCHEDULE) SHEAR WALL <br /> o _ / PER PLAN <br /> Eo 11 , <br /> 3/4"T&G APA 24/6 RATED Cr) <br /> PLYWD SHEATHING GLUED olio (I/ <br /> &NAILED TO FLOOR JOISTS \ L.L <br /> WINDOW SCHEDULE I J LO ® o0 <br /> AREA SUMMARY EGRESS 1 R-21 INSULATION ee a) <br /> ID SIZE AREA litiitã <br /> R-8INSULATION OVER a < <br /> UPPER FLOOR 977 S . FT. 5.7 SQ FT MIN OPENABLE AREA �' <br /> Q 20" MIN. OPENABLE WIDTH 1 5040 20.0 SQ. FT. 1 VH UNHEATE SPACE Z N <br /> LOWER FLOOR 779 SQ. FT. 24" MIN. OPENABLE HEIGHT 1 <br /> TOTAL HEATED AREA 1756 SQ. FT. 44" MAX ABOVE FIN. FLOOR 2 •5040 20.0 SQ. FT. '/, � J O <br /> GARAGE 413 SQ. FT. z oI <br /> 3 2030 6.0 SQ. FT. 2 ° J <br /> FLOOR JOIST <br /> GLAZING SUMMARY GLAZING 4 5040 20.0 SQ. FT. C° PER PLAN ° (W� <br /> GLAZING AREA(% OF FLOOR) 11.3% Zo `� <br /> TOTAL GLAZING AREA 191.0 SQ. FT. 5 4040 16.0 SQ. FT. . c� <br /> GLAZING: (191 / 1756= 10.9%) U-FACTORS (VERTICAL GLAZING/DOORS) 0.30 CRAWLSPACE GRADE �J O ool W <br /> U-FACTORS (OVERHEAD GLAZING) 0.50 > <br /> 6 5040 20.0 SQ. FT. ° �� <br /> INSULATION VALUES W <br /> 2015 WASHINGTON STATE ENERGY CODE REQUIREMENTS 7 3020 6.0 SQ. FT. 4" PERFORATED <br /> VAULTED CEILINGS: R-38 BATT (500 SQ FT MAX.) FOOTING DRAIN <br /> SEC 401.3 POST ENERGY CODE COMPLIANCE CERTIFICATE WITHIN VAULTED SCISSOR: R-49 BATT OR BLOWN 8 60610 40.0 SQ. FT. EQ. .-- ,-.., ..- pi <br /> 8" EQ. SURROUND W/GRAVEL <br /> 3 FT OF ELECTRICAL PANEL AVAILABLE AT FLAT CEILINGS: R-49 BATT OR BLOWN 9 2040 4.0 SQ. FT. <br /> r•411'-4" <br /> WWW.ENERGY.WSU.EDU/CODE. EXTERIOR WALLS: R-21 BATT r <br /> SEC 402.4.1 PROVIDE DOOR BLOWER TEST AFFIDAVIT BY FINAL FLOOR w/CRAWLSPACE: R-30 BATT 10 2040 4.0 SQ. FT. <br /> BUILDING INSPECTION SLAB ON GRADE: R-10 RIGID PERIMETER TYPICAL SECTION <br /> SEC 403.1.1 PROVIDE (1) PROGRAMMABLE THERMOSTAT 11 2040 8.0 SQ. FT. FLOOR PLANS <br /> SEC 403.2.2 PROVIDE DUCT SEALING AFFIDAVIT BY FINAL SCALE: 3/4" = 1' 0" <br /> INSPECTION FANS- BATHROOM 50 CFM MIN (UNO),VENT OUTSIDE <br /> SEC 404.1 A MINIMUM OF 75% OF ALL PERMANENTLY INSTALLED KITCHENS 100 CFM 12 1050 5.0 SQ. FT. <br /> LIGHTING SHALL HAVE HIGH EFFICACY LIGHTING WHOLE HOUSE 75 CFM, CONTINUOUS PER 2015 IRC M1507.3.3(1) <br /> 13 4040 16.0 SQ. FT. <br /> PROVIDE WHOLE HOUSE EXHAUST, CONTINUOUS FAN, 4-5 BEDROOM, 1501-3000 SQ FT, 75 CFM AIRFLOW. 14 2030 6.0 SQ. FT. REVISION: 2 <br /> DATE: 10-14-19 <br /> WHOLE HOUSE FAN: LABEL SHALL BE AFFIXED TO THE CONTROL THAT READS"WHOLE HOUSE VENTILATION (SEE DRAWN BY: TJM <br /> OPERATING INSTRUCTIONS)"2015 IRC M 1507.3.3 <br /> DRYER VENT 2015 IRC M1502.4.5 LENGTH IDENTIFICATION. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE TOTAL 191.0 SQ. FT. SCALE: AS NOTED <br /> BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT PROJECT NO: W4580 <br /> LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6'OF THE EXHAUST DUCT CONNECTION. CITY OF EVERE T T <br /> REVIEWED FOR PERMIT SHEET NO: <br /> PROVIDE A 4 SQ IN FRESH AIR INLET TO EACH LIVING AREA. <br />