Laserfiche WebLink
32'-0" z <br /> 0 <br /> LANDINGS SHALL 5 <br /> BE NO MORE THAN 7'-71/2" 11'-612" 12'-10" in <br /> 36" 7-3/4" BELOW 1.-'-a- —' - ® C <br /> LANDING FINISHED FLOOR z z O <br /> 7 9 1 2 3 0_ 0 0 <br /> 2040 8 3020 . 2030 5040 5040 ° w w <br /> l ' <br /> I I 1 1 1 1 1 1 1 1 I 1 1_ 1 1 <br /> 60610 SLIDER e w O O <br /> SAFETY GLASS oo (0--14 <br /> 0 U U <br /> �Q,�S�G �� wcn cn4 <br /> G� Q / 110 11' 3" ® a 12' 1" ❑ a) 6 <br /> o ���� 3209 5 I° <br /> c <br /> N _ FAN �* <br /> ❑ i81. \ \ w <br /> -1 O dr 9 r N <br /> 0 0 N 30" BEDROOM 2 r N <br /> =N KITCHEN (/) 71 J O DOOR r '- <br /> GREATROOM r o 30" r 'n <br /> b DOOR M. BEDROOM r co <br /> Z <br /> � w <br /> SD C c' z <br /> cow <br /> - REFER. e i NU <br /> PANTRY CLOSET <br /> le3 ' CLOSET 2'-8' <br /> FAN f SD DOOR L , <br /> cc e <br /> `1' 00 UP •- 3'-6" <br /> 1 <br /> .. N0 I 2' 8" <br /> 1 SD l o� _ \ my <br /> co DOOR o %s"APA 2446 RATED OSBCMD �o SD _ co <br /> O `�' e > CMD C° SHEATHING W/6d @ 6"O.C. CLZ <br /> 0 FURN pp0 �, DOWN HANDRAIL EDGE& 12" O.C. FIELD NAILING a <br /> o EFFICIENT WATER 'Q (U.N.O. IN NOTES) _i z 00 M <br /> Op HEATER PER 5B 3'-2" 3215 <br /> CO Z4 00 1 o R-49 E2 2 rn <br /> TABLE R406.2 / 20 MIN. FAN N <br /> BOLLARD SOLID CORE/STEEL I ❑ 3215 HALF WALL I b INSULATION D w Q Q <br /> (2)SEISMIC W/SELF CLOSER \_ } r 3'-2" 00 SD d' INSULATION U Z <br /> STRAPS. FOR GAS APPLIANCES 1 WHOLE W e ROOF TRUSS BAFFLE I- H ° w <br /> PRESS. RELIEF ELEVATE IGNITION SOURCE HOUSE z <br /> TO EXT. 18"A.F.F. IN GARAGE AND CLOSET L PER FRAMING Q CC Z w <br /> PROVIDE IMPACT r M DO FAN 22ATTIC 0 11'-6�2" PLAN 7 W O I� Z <br /> / IIIIIIII ��W m <br /> PROTECTION. L. ❑ ARC. D a_ DRYER VENT 1111111111111111 - R-21 INSULATION <br /> SD I THROUGH ROOF. 1 �� <br /> e 60 0 ' mI/ 10-14-19 <br /> _ N 0 5/8" <br /> ❑ CLOSET H1 CLIP AT EACH TRUSS �j MSC <br /> HI LOW ‘1)\1- �_ "--c:1 GWB r) Z• A <br /> COMBUSTION ENTRY '' 2'-8" TO DBL TOP PLATE/HEADER 1111 ,�1 hN d <br /> �J .e Hns/0 <br /> I AIR 9'-8" _ ElOOR 0 OR BEAM CONNECTION III 1'-0" • . y P; °��� <br /> VENTILATION 11'-612" o .1 / in..] <br /> SD BONUS ROOM RIGID INSULATIONCA <br /> ' ® 4 e BEHIND HEADER(R-10) �� +. ` .0' <br /> OOP 7p Gcp, 38799 k' .cf,,w <br /> GARAGE T BEDROOM 4 9'-11/2" 0 2x6 STUDS / ��sjo NLE � <br /> 1/2" GWB- WARM WALLS - Eo @ 16" O.C. <br /> COP <br /> SUPPORT MEMBERS <br /> 5/8" GWB- TYPE X CEILING SHEAR WALL <br /> 10 4 3/4"T&G APA 2446 RATED Fil 7- <br /> 36" I 4040 I ' ' , N BEDROOM 3 I 5040 I I ' PLYWD SHEATHING GLUED PER PLAN <br /> 1 r ' &NAILED TO FLOOR JOISTS \ <br /> DOOR 6 <br /> I 5040 I 2x6 BASE PLATE <br /> 4 A o (NAILING PER SHEAR R21 <br /> ' I 16 FT GARAGE DOOR I ' WALL SCHEDULE) / i <br /> INSULATION <br /> moi- 1 iii <br /> 5 iii <br /> JOISTS VAPOR <br /> ' 1 I 5040 I I PER PLAN BARRIER <br /> 2x6 BASE PLATE <br /> 5'-6" 9'-11Y2" �,0 10' 0�2" �� 12'-0" (NAILING PER SHEAR �� SHEAR WALL <br /> 20'-0" rim 12'-0" T 32'-0" o WALL SCHEDULE) .01 / <br /> _ PER PLAN <br /> 32' 0" r <br /> 3/4"T&G APA 24/6 RATED <br /> PLYWD SHEATHING GLUED—\ <br /> &NAILED TO FLOOR JOISTS <br /> LOWER FLOOR PLAN UPPER FLOOR PLAN R-211NSULATION <br /> SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" V @WALL <br /> �'III"""! R-38 INSULATION OVER <br /> illllllli <br /> I�� UNHEATED SPACE <br /> \ N z <br /> z_ <br /> 2 FLOOR JOIST r ° <br /> CO PER PLAN ° <br /> f CRAWLSPACE GRADE • -' • O �f <br /> o Q I I N Co <br /> 4" PERFORATED (0 L.L O <br /> 0 00 <br /> AREA SUMMARY EGRESS EQ. o 8" EQ. SURROUNFOOTING D GRAVEL 00 Q 0) <br /> M.- pl 'V'-- <br /> 5.7 SQ FT MIN OPENABLE AREA 1' 4" 7 o Q <br /> UPPER FLOOR 1114 SQ. FT. 20" MIN. OPENABLE WIDTH r'•• Z <br /> LOWER FLOOR 752 SQ. FT. 24" MIN. OPENABLE HEIGHT Q ~TOTAL HEATED AREA 1866 SQ. FT. YINDOYSCHEDULG TYPICAL SECTION <br /> 44" MAX ABOVE FIN. FLOOR <br /> a 0 <br /> GARAGE 415 SQ. FT. ID SIZE AREA SCALE: 3/4" = 1'-0" 0... J J <br /> GLAZING SUMMARY GLAZING L_ W <br /> 1 2030 6.0 SQ. FT. C �„ �/ <br /> TOTAL GLAZING AREA 214.0 SQ. FT. GLAZING AREA(%OF FLOOR) 9.3% - G `('I`^c� <br /> GLAZING: (184/ 1866-9.9%) U-FACTORS (VERTICAL GLAZING/DOORS) 0.30 2 5040 20.0 SQ. FT. Q \ W <br /> U-FACTORS (OVERHEAD GLAZING) 0.50 \ > <br /> 3 5040 20.0 SQ. FT. W <br /> INSULATION VALUES <br /> 2015 WASHINGTON STATE ENERGY CODE REQUIREMENTS 4 5040 20.0 SQ. FT. <br /> VAULTED CEILINGS: R-38 BATT(500 SQ FT MAX.) <br /> SEC 401.3 POST ENERGY CODE COMPLIANCE CERTIFICATE WITHIN VAULTED SCISSOR: R-49 BATT OR BLOWN 5 5040 20.0 SQ. FT. <br /> 3 FT OF ELECTRICAL PANEL AVAILABLE AT FLAT CEILINGS: R-49 BATT OR BLOWN <br /> WWW.ENERGY.WSU.EDU/CODE. EXTERIOR WALLS: R-21 BATT 6 5040 20.0 SQ. FT. <br /> SEC 402.4.1 PROVIDE DOOR BLOWER TEST AFFIDAVIT BY FINAL FLOOR w/CRAWLSPACE: R-30 BATT <br /> BUILDING INSPECTION SLAB ON GRADE: R-10 RIGID PERIMETER 7 2040 8.0 SQ. FT. <br /> SEC 403.1.1 PROVIDE (1) PROGRAMMABLE THERMOSTAT FLOOR PLANS <br /> SEC 403.2.2 PROVIDE DUCT SEALING AFFIDAVIT BY FINAL 8 60610 SL 40.0 SQ. FT. <br /> INSPECTION FANS- BATHROOM 50 CFM MIN (UNO),VENT OUTSIDE <br /> SEC 404.1 A MINIMUM OF 75% OF ALL PERMANENTLY INSTALLED KITCHENS 100 CFM 9 3020 6.0 SQ. FT. <br /> LIGHTING SHALL HAVE HIGH EFFICACY LIGHTING WHOLE HOUSE 75 CFM, CONTINUOUS PER 2015 IRC M1507.3.3(1) <br /> 10 4040 16.0 SQ. FT. <br /> PROVIDE WHOLE HOUSE EXHAUST, CONTINUOUS FAN, 4-5 BEDROOM, 1501-3000 SQ FT, 75 CFM AIRFLOW. REVISION: 2 <br /> 11 2040 8.0 SQ. FT. <br /> DATE: 10-14-19 <br /> WHOLE HOUSE FAN: LABEL SHALL BE AFFIXED TO THE CONTROL THAT READS "WHOLE HOUSE VENTILATION (SEE DRAWN BY: TJM <br /> OPERATING INSTRUCTIONS)"2015 IRC M 1507.3.3 <br /> DRYER VENT 2015 IRC M1502.4.5 LENGTH IDENTIFICATION. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE SCALE: AS NOTED <br /> BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT CITY OF EVERETT PROJECT NO: W4552 <br /> LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6' OF THE EXHAUST DUCT CONNECTION. TOTAL 184.0 SQ. FT. REVIEWED FOR PERMIT SHEET NO: <br /> PROVIDE A 4 SQ IN FRESH AIR INLET TO EACH LIVING AREA. <br />