Laserfiche WebLink
co <br /> z <br /> O <br /> 5w <br /> CZ <br /> 30'-0" cn cn <br /> z z z <br /> O O O <br /> F= r= F- <br /> n- U U <br /> ULu Lu <br /> Et tY <br /> m ct W <br /> 30'-0" w 0 0 <br /> LANDINGS SHALL <br /> BE NO MORE THAN 1 11'-0/2" 11'-4" 7'-7)2" <br /> 7-3/4" BELOWT - rn <br /> FINISHED FLOOR w °' <br /> 7 8 9 1 2 3 0 0 0 <br /> 3020 ( i 2040 I 5040 5040 Th <br /> I I 12030 <br /> aorro. 60610 SLIDERil <br /> o 'p SAFETY GLASS 1 0 W <br /> O O ° <br /> N <br /> rn <br /> 3215w <br /> 00 <br /> 0O = Em FAN CO <br /> Mw <br /> 00 o 30„ m <br /> O KITCHEN _ N MASTER .N DOOR r-..-b BEDROOM <br /> LIVING ROOM E. <br /> BEDROOM 30" ��°-�� "' <br /> 2 DOOR <br /> _r\c- o SD <br /> @ t <br /> PANTRY O G� N SSD * Q <br /> ai) CL= Z <br /> '1,Q`", G� , C° 7'-2" a <br /> P J <br /> 9 3 SD <br /> G� C9�Q\ / J CO p o <br /> L Z O <br /> FAN CMD �\Q- CLOSET S = rn <br /> N <br /> �t ��� ' 32" r -I 32" i 1 ' f- }-- <br /> W a <br /> 50" 53 <br /> �J 0 DOOR DOOR SD c <br /> �°) cj Q C� cwn ui <br /> J �9� 3c0� 15' 07\8, CMD ° _ coN. Q <br /> FURN =_— i? III <br /> W 0 I- Z o co z <br /> CD 00 EFFICIENT WATER ~ - <br /> rn m <br /> co o �� HEATER PER 56 >HANDT__ 30" 3215 to o <br /> `V 20 MIN. BOLLARD-/ \ TABLE R406.2 0 1 3215 DOOf� FAN -8„ M 10-14-19 <br /> 00 <br /> _ / -1SOLID CORE/STEEL (2)SEISMIC <br /> W/SELF CLOSER FOR GAS APPLIANCES STRAPS. WHOLE 3'-2„ T <br /> C2 <br /> MSC <br /> J �7 OF WASy�'47 <br /> ELEVATE IGNITION SOURCE PRESS. RELIEF \ _ \ = HO�E— S <br /> ® 6'-3" 0 18"A.F.F. IN GARAGE AND TO EXT. `NI 22x30 AN 36" CLOSET /6"APA 24/6 RATED OSB :`�,if '' -�1,: GTo�,, <br /> PROVIDE IMPACT \ / JATTIC DOOR -1 —� <br /> I SHEATHING W/6d @ 6"O.C. <br /> PROTECTION. \ / ��CCES• EDGE & 12 O.C. FIELD NAILING <br /> (U.N.O. IN NOTES) '. <br /> =N \\ / r 30" SD R 49 fig.{ 38799 x$ . w <br /> M \ DOOR e INSULATION 4,, RAL <br /> V,.- <br /> co HI LOW / CLOSET INSULATION <br /> COMBUSTION = Q ROOF TRUSS BAFFLE <br /> 19 AIR N \ / DOOR PER FRAMING <br /> VENTILATION \ / A PLAN 7 <br /> \ / BEDROOM / II�I�II pliSN <br /> f ENTRY OPE TOSD <br /> 4 = �♦�t�1��1�♦��c�1��1�1 �� R-21 I N S U LATIO N <br /> UP - BELOW d I <br /> GARAGE <br /> / \ 5/8' <br /> GWB H1 CLIP AT EACH TRUSS <br /> 12 _ BEDROOM TO DBL TOP PLATE/HEADER <br /> GARAGE / \ ii1 OR BEAM CONNECTION <br /> 3 -0 <br /> f 10Li 50 36" I _ ! 1/2" GWB- WARM WALLS \ N RIGID INSULATION <br /> SAFETY DOOR SUPPORT MEMBERS / \ <br /> GLASS 5/8" GWB- TYPE X CEILING BEHIND HEADER(R-10) <br /> o0 2x6 STUDS / <br /> / \ �, 8'-7" 9- 0 ao @ 16" O.C. • <br /> 5040 L <br /> I • i i f / \ 1 1 1 SHEAR WALL <br /> \ - %4"T&G APA 24/6 RATED PER PLAN <br /> 6 5 PLYWD SHEATHING GLUED \ <br /> ' / 5040 i i\ 4040 i &NAILED TO FLOOR JOISTS <br /> 10'-0" 20'-0" 10'-6�2" 9'-6" 9'-11 2" 2x6 BASE PLATE <br /> 7 20'-0�2" 7 _ (NAILING PER SHEAR R21 <br /> 1--* 0 WALL SCHEDULE) / INSULATION <br /> 1 IiII <br /> JOISTS <br /> VAPOR misI <br /> PER PLAN BARRIER <br /> LOWER FLOOR PLAN UPPER FLOOR PLAN 11 <br /> SCALE: 1/4"= 1'-0" SCALE: 1/4"= 11-0" 2x6 BASE PLATE <br /> °- (NAILING PER SHEAR SHEAR WALL <br /> 0 <br /> WALL SCHEDULE) / PER PLAN <br /> co <br /> 3/4"T&G APA 24/6 RATED (Y) <br /> PLYWD SHEATHING GLUEDN <br /> CD <br /> &NAILED TO FLOOR JOISTS \ N LL N <br /> a00 <br /> AREA SUMMARY EGRESS ', R 21 INSULATION CO <br /> 1111115.7 SQ FT MIN OPENABLE AREA 1 R 8AINSULATION OVER a <UPPER FLOOR 977 SQ. FT. <br /> 20" MIN. OPENABLE WIDTH I UNHEATE SPACE Z <br /> LOWER FLOOR 685 SQ. FT. z� Q 1 n/ <br /> TOTAL HEATED AREA 1662 SQ. FT. 24 MIN. OPENABLE HEIGHT WINDOW <br /> ®®,A, SCHEDULE \I LL <br /> 44' MAX ABOVE FIN. FLOOR Y Y N Y Y t\\" , --In <br /> o <br /> GARAGE 413 SQ. FT. z O J <br /> ID SIZE AREA 2 F....FLOOGLAZING SUMMARY GLAZING C° P R PRAM p I.L. <br /> W <br /> 1 5040 20.0 SQ. FT.. �y <br /> TOTAL GLAZING AREA 187.0 SQ. FT. GLAZING AREA(% OF FLOOR) 11.3% o LL <br /> o U-FACTORS (VERTICAL GLAZING/DOORS) 0.30 2 5040 20.0 SQ. FT.(OVERHEADGLAZING) 0 50 o _ W <br /> GLAZING: (187/ 1662= 11.3/a) U-FACTORSf CRAWLSPACE GRADE J •o c O C 00f <br /> 3 2030 6.0 SQ. FT. ° t"' W <br /> INSULATION VALUES 4" PERFORATED <br /> 2015 WASHINGTON STATE ENERGY CODE REQUIREMENTS 4 5040 20.0 SQ. FT. FOOTING DRAIN <br /> VAULTED CEILINGS: R-38 BATT(500 SQ FT MAX.) <br /> SEC 401.3 POST ENERGY CODE COMPLIANCE CERTIFICATE WITHIN VAULTED SCISSOR: R-49 BATT OR BLOWN 5 5040 20.0 SQ. FT. EQ. 8" EQ. SURROUND W/GRAVEL <br /> 0 E0 <br /> 3 FT OF ELECTRICAL PANEL AVAILABLE AT FLAT CEILINGS: R-49 BATT OR BLOWN <br /> WWW.ENERGY.WSU.EDU/CODE. EXTERIOR WALLS: R-21 BATT 6 5040 20.0 SQ. FT. 1'-4" <br /> SEC 402.4.1 PROVIDE DOOR BLOWER TEST AFFIDAVIT BY FINAL FLOOR w/CRAWLSPACE: R-30 BATT - <br /> BUILDING INSPECTION SLAB ON GRADE: R-10 RIGID PERIMETER 7 3020 6.0 SQ. FT. TYPICAL SECTION <br /> SEC 403.1.1 PROVIDE (1) PROGRAMMABLE THERMOSTAT FLOOR PLANS <br /> SEC 403.2.2 PROVIDE DUCT SEALING AFFIDAVIT BY FINAL 8 60610 SL 40.0 SQ. FT. SCALE: 3/4" = 11-0" <br /> INSPECTION FANS- BATHROOM 50 CFM MIN (UNO),VENT OUTSIDE <br /> SEC 404.1 A MINIMUM OF 75% OF ALL PERMANENTLY INSTALLED KITCHENS 100 CFM 9 2040 8.0 SQ. FT. <br /> LIGHTING SHALL HAVE HIGH EFFICACY LIGHTING WHOLE HOUSE 75 CFM, CONTINUOUS PER 2015 IRC M1507.3.3(1) <br /> 10 2040 8.0 SQ. FT. <br /> PROVIDE WHOLE HOUSE EXHAUST, CONTINUOUS FAN, 4-5 BEDROOM, 1501-3000 SQ FT, 75 CFM AIRFLOW. REVISION: 2 <br /> 11 2040 8.0 SQ. FT. DATE: 10-14-19 <br /> WHOLE HOUSE FAN: LABEL SHALL BE AFFIXED TO THE CONTROL THAT READS"WHOLE HOUSE VENTILATION (SEE <br /> OPERATING INSTRUCTIONS)"2015 IRC M 1507.3.3 12 1050 5.0 SQ. FT. DRAWN BY: TJM <br /> DRYER VENT 2015 IRC M1502.4.5 LENGTH IDENTIFICATION. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE 13 2030 6.0 SQ. FT. SCALE: AS NOTED <br /> BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT PROJECT NO: W4575 <br /> LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6' OF THE EXHAUST DUCT CONNECTION. TOTAL 187.0 SQ. FT. CITY OF EVERETT <br /> PROVIDE A 4 SQ IN FRESH AIR INLET TO EACH LIVING AREA. REVIEWED FOR PERMIT SHEET NO: <br /> S3 <br />