Simple Heating System Size: 2015 Washington State Windows and Doors <br /> W <br /> Prepared by: Dennis Smiley/ Emerald Home Design Quantity Width Ft Width In Height Ft Height In R406 ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS (,) <br /> Windows 1 7 0 4 0 E <br /> Builder- 112th LLC 4 5 0 4 0 Medium Dwelling Unit (1500-5000 SF) requires 3.5 point from table R406 0 <br /> 04� <br /> Plan Name 1452 Slab Floor 1 7 0 5 0 0 E W <br /> 1 2 o 5 0 This project selects the following: v co <br /> Design Temp = 21 /70 deg- 21 49 1 5 6 3 0 z <br /> 2 4 0 4 0 Q.Z. Z <br /> Conditioned Floor Area 1,452 1 2 0 3 0 EFFICIENT BUILDING ENVELOPE 1a: J <br /> Average Ceiling Ht 8.48 1 4 0 3 6 Prescriptive compliance is based on Table R402.1.1 with the following modifications: 00 0. <br /> Conditioned Volume 12311 0 0 0 0 0 Vertical fenestration U = 0.28 <br /> 0 0 0 0 0 Floor R-38 E § <br /> Component U-Factor Area UA 0 0 0 0 0 Slab on grade R-10 perimeter and under entire slab <br /> Glazing and Doors 0.280 328 91.7 0 0 0 0 0 Below grade slab R-10 perimeter and under entire slab § Al <br /> Skylights 0.500 4 2.0 0 0 0 0 0 or o <br /> Attic Area - R-49 0.026 1,040 27.0 0 0 0 0 0 <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 5%. �y <br /> Above Grade Walls- R-21 Int 0.056 1,644 92.1 0 0 0 0 0 0.5CREDITS m <br /> Floors- R-38 0.025 570 14.3 Glass Doors 2 5 0 6 10 <br /> Below Grade Walls - R-21 Interior 0.042 0 0.0 0 0 0 0 0 <br /> Slab Below Grade - R-5 Thermal Break at slab edge 0.570 - 0.0 0 0 0 0 0 <br /> Z <br /> Slab on Grade R-10 Perimeter 0.540 88.00 47.5 Non-Glass Doors 1 3 0 6 8 HIGH EFFICIENCY HVAC EQUIPMENT 3a: <br /> 1 2 8 6 8 Gas, propane ane or oil-fired furnace with minimum AFUE of 94%, or (09 <br /> Duct Leakage Coefficient 0 0 0 0 0 <br /> Gas, propane or oiled-fired boiler with minimum AFUE of 92% miumi <br /> Location of Ducts - Unconditioned Space 1.1 Total SF 328 To qualify to claim this credit, the building permit drawings shall specify the option <br /> being selected and shall specify the heating equipment type and the minimum co <br /> Sum of UA 275 Mechanical Ventilation equipment efficiency. <br /> LLIEnvelope Heat Load 13457 <br /> Air Leakage Heat Load 6515 This Project Floor Area 1,452 1.0 CREDITS <br /> Building Design Heat Load 19972 This Project Number of Bdrs 4Cma <br /> Building Duct Heat Load 21969 <br /> Maximum Heat Equipment Output 30756 Table M1507.3.3(1) <br /> Continuous Whole House Mechanical Ventilation EFFICIENT WATER HEATING 5a: CI <br /> All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 zit E <br /> TABLE R402.1.1 Fl Area 0-1 Bdrs 2-3 Bdrs 4-5 Bdrs 6-7 Bdrs >7 Bdrs GPM or less. All other lavatory faucets shall be rated at 1 .0 GPM or less. <br /> INSULATION AND FENESTRATION REQUIREMENT BY COMPONENT(a) <1500 30 45 60 75 90 G Ce 0 <br /> 1501-3000 45 60 75 90 105 To qualify to claim this credit, the building permit drawings shall specify the option <br /> FENESTRATION U-FACTOR (b) 0.28 3001-4500 60 75 90 105 120 being selected and shall specify the maximum flow rates for all showerheads, kitchen 2 <br /> SKYLIGHT(b) U-FACTOR 0.5 4501-6000 75 90 105 120 135 sink faucets, and other lavatory faucets. LLW <br /> GLAZED FENESTRATION SHGC(b,e) NR 6001-7500 90 105 120 135 150 <br /> CEILING R-VALUE (k) 49 >7500 105 120 135 150 165 0.5 CREDITS <br /> WOOD FRAM WALL (g,m.n) R-VALUE 21 INT <br /> MASS WALL R-VALUE (i) 21/ 21 Table M1507.3.3(2) <br /> FLOOR R-VALUE 38 Runtime Percentage and Multiplying Factor <br /> BELOW GRADE (c,m) WALL R-VALUE 10/15/21 INT+TB 25% 33% 50% 66% 75% 100% EFFICIENT WATER HEATING 5c: W <br /> SLAB (d) R-VALUE AND DEPTH 10, 2 FT 4 3 2 1.5 1.3 1 Water heating system shall include one of the following: 0 <br /> Gas, propane or oil water heater with a minimum EF of 0.91 Q <br /> or W <br /> For SI: 1 foot = 304.8 mm, ci = continuous insulation, int = intermediate framing. M1507.2 Recirculation of air. Exhaust air from bathrooms Solar water heating supplementing a minimum standard water heater. Solar water <br /> and toilet rooms shall not be recirculated within a residence heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the <br /> 0 <br /> (a) R-values are minimums. U-factors and SHGC are maximums. When or to another dwelling unit and shall be exhausted directly to Solar Rating and Certification Corporation (SRCC) Annual Performance of OG-300 CO <br /> Certified Solar Water HeatingSystems. �.° <br /> a <br /> insulation is installed in a cavity which is less than the label or design thickness of the outdoors. Exhaust air from bathrooms and toilet rooms y W <br /> the insulation, the compressed R-value of the insulation from Appendix Table shall not discharge into an attic, crawl space or other areas or <br /> lc w <br /> A101 .4 shall not be less than the R-value specified in the table. inside the building. <br /> Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards <br /> 0 pe <br /> of <br /> ce <br /> (b) The fenestration U-factor column excludes skylights. The SHGC column M1507.3 Whole-house mechanical ventilation system. NEEA's Northern Climate Specifications for Heat Pump Water Heaters. I `CV <br /> applies to all glazed fenestration. Whole-house mechanical ventilation systems shall be To qualify to claim this credit, the building permit drawings shall specify the option <br /> designed in accordance with Sections M1507.3.1 through being selected and shall specify the water heater equipment type and the minimum W ' <br /> (c) "10/15/21 +TB" means R-10 continuous insulation on the exterior of the wall, equipment efficiency and, for solar water heating systems, the calculation of theLL <br /> M1507.3.3. minimum energy savings. <br /> or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation Q <br /> plus a thermal break between the slab and the basement wall at the interior of M1507.3.1 System design. The whole-house ventilation 1.5 CREDITS I J <br /> the basement wall. "10/15/21 +TB" shall be permitted to be met with R-13 cavity system shall consist of one or more supply or exhaust fans, co <br /> CI- <br /> insulation on the interior of the basement wall plus R-5 continuous insulation on or a combination of such, and associated ducts and controls. <br /> the interior or exterior of the wall. "TB" means thermal break between floor slab Local exhaust or supply fans are permitted to serve r <br /> , , <br /> and basement wall. as such a system. Outdoor air ducts connected to the return a. Projects using this option may not use Option la, 1 b or lc. W C, <br /> side of an air handler shall be considered to provide supply ® W <br /> (d) R-10 continuous insulation is required under heated slab on grade floors. See ventilation. b. Projects may only include credit from one space heating option, 3a, 3b, 3c or 3d. When J 0 <br /> R402.2.9.1. a housing unit has two pieces of equipment (i.e., two furnaces) both must meet the <br /> n Die <br /> M1507.3.2 System controls. The whole-house mechanical <br /> standard to receive the credit. <br /> (e) There are no SHGC requirements in the Marine Zone. ventilation system shall be provided with controls that <br /> enable manual override. c. Plumbing Fixtures Flow Ratings. Low flow plumbing fixtures (water closets and urinals) <br /> (i) The second R-value applies when more than half the insulation is on the and fittings (faucets and showerheads) shall comply with the following requirements: DATE: <br /> interior of the mass wall. M1507.3.3 Mechanical ventilation rate. The wholehouse <br /> mechanical ventilation system shall provide outdoor 1. Residential bathroom lavatory sink faucets: Maximum flow rate - 3.8 L/min (1.0 gal/min) 8/19/2019 <br /> (k) For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R- air at a continuous rate of not less than that determined in when tested in accordance with ASME A112.18.1/CSA B125.1. <br /> 38. accordance with Table M1507.3.3(1). 2. Residential kitchen faucets: Maximum flow rate - 6.6 L/min (1.75 gal/min) when tested <br /> in accordance with ASME A112.18.1/CSA B125.1. EHD JOB: <br /> (m) Int. (intermediate framing) denotes standard framing 16 inches on center with Exception: The whole-house mechanical ventilation 3. Residential showerheads: Maximum flow rate - 6.6 L/min (1 .75 gal/min) when tested in <br /> headers insulated with a minimum of R-10 insulation. system is permitted to operate intermittently where the accordance with ASME A112.18.1/CSA B125.1. 2345 <br /> system has controls that enable operation for not less <br /> (n) Log and solid timber walls with a minimum average thickness of 3.5 inches than 25-percent of each 4-hour segment and the ventilation CITY OF EVERETT SHEET: <br /> are exempt from this insulation requirement. rate prescribed in Table M1507.3.3(1) is multiplied REVIEWED FOR PERMIT <br /> by the factor determined in accordance with Table <br /> M1507.3.3(2). SLAB FLOOR OPTION 1 2 <br />