Laserfiche WebLink
W <br /> V <br /> GENERAL NOTES <br /> ROOFING MATERIAL TO BE <br /> ALL CONSTRUCTION SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL 2X8 PT LEDGER AT WALL WITH 1/2 X 4" MID ROOF"UNDER SHINGLE"VENTING TO COMPOSITION OVER 30LB FELT V <br /> STAGGERED LAG BOLTS AT 18"OC INTO RIM PROVIDE LOWER ATTIC VENTILATION. EX <br /> 7/16"OSB ROOF W <br /> CODE,2015 INTERNATIONAL BUILDING CODE,AND THE 2015 WASHINGTON STATE4X4 SUPPORT POST SHEATHING.8D AT 6" \ 0 '^ <br /> ENERGY CODE. • <br /> JOIST. LAG BOLTS SHALL BE Z' FROM TOP OR (+, <br /> RIM JOIST OC AT EDGES AND <br /> BOTTOM AND 2"TO 5" FROM ENDS OF LEDGER <br /> R-408.2 (WAC 51-51)UNDERFLOOR VENTILATION REQUIRES 1 SQ FT OF NET FREE \� / SOLID TIGHT FITTING 12"OC AT FIELD Z <br /> SIDING BLOCKING(NO VENTS) ' INSULATION <br /> H1 ROOF TO TOP PER ENERGY <br /> CROSS VENTILATION FOR EACH 300 SQ FT OF UNDERFLOOR AREA COVERED. �' " PLATE CONNECTION \ ''" INFORMATION ® '� <br /> R-408A UNDERFLOOR ACCESS: MINIMUM 18"X 24"CLEAR ACCESS THROUGH G METAL FLASHING DTT2 CONNECTOR 411 I M ll MEM <br /> AT EACH TRUSSF6 0.. Iftftil <br /> PAU:/ <br /> _ m VENTED 2X _e I I 0 � -. v♦ <br /> R-317.1 WOOD FLOOR JOIST CLOSER THAN 18"AND WOOD GIRDERS CLOSER THAN ° ° ` ����� _ <br /> r-, { INSULATION PER ENERGY BLOCKING � <br /> ,o° ° 101' <br /> oo° ° ° °o° ,.,- INSULATION BAFFLE WITH 1" <br /> 12"FROM THE EXPOSED GROUND MUST BE PRESSURE TREATED. ° ° ° ° ° ° °'\° ° \/ INFORMATION PAGE II / MIN AIR SPACE TO EXTENDIQ <br /> FASTENERS INTO OR IN CONTACT WITH PRESSURE TREATED OR FIRE RETARDANT LUS28 `NEW RIM JOIST 1 6„ HEADER PER PLAN 0 ULATION VERTICALLY ABOVE CZ <br /> TREATED WOOD SHALL BE OF HOT-DIPPED GALVANIZED STEEL, STAINLESS STEEL, MSTC28 OR(2)HTT4 / SHEATHING PERmmall <br /> ® <br /> SILICON BRONZE OR COPPER. EXCEPTION: 1/2 INCH DIAMETER OR GREATER STEEL AT TWO LOCATIONS TO SW SCHEDULE <br /> 2X8 DECK JOISTS �yy <br /> BOLTS. CONNECT FLOOR SOLID BLOCKING NOTE: GABLE ENDS THAT ARE DIRECTLY UP AGAINST <br /> DIAPHRAGM TO DECK JOISTS 5 FT SETBACK SHALL HAVE NO GABLE VENTS 2X6 WALL FRAMING AT 16"OC <br /> R-806.2 ATTIC VENTILATION REQUIRES NET FREE CROSS VENTILATION 1/150 OF Ca • <br /> ATTIC AREA.OR 1/300 IF 40-50 PERCENT IS UPPER VENTILATION.VENTED BLOCKING <br /> AND GABLE END VENTING IS NOT ALLOWED WHEN THE EXTERIOR WALL IS 5 FT OR ROOF OVERHANG INTRUDING INTO TYPICAL ROOF TO WALL <br /> LESS FROM THE PROPERTY LINE OR WHEN THE EAVE OR OVERHANG IS LESS THAN D4 DECK CONNECTION TO WALL D3 4X4 DECK RAILING POST SUPPORT D2 5 FT PROPERTY LINE SETBACK D1 AND HEADER SECTIONZ . . <br /> 5 FT FROM THE PROPERTY LINE.WHEN APPLICABLE SEE D2 <br /> R-807 ATTIC ACCESS REQUIRES 22"X 30"MIN CLEAR OPENING IN A READILY (ID . . '. ,• <br /> ACCESSIBLE AREA.30"MIN HEADROOM, INSULATE AND WEATHERSTRIP <br /> ROOF TO WALL - 1'-6" 1 HOUR FIRE PROTECTION <br /> 8D NAILS AT 6"OC PERIMETER ii PROVIDED BY 5/8"GWB AT BATT INSULATION PER BATT INSULATION PER <br /> R-310 EGRESS OPENINGS SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44" FLASHING ALL SIDES ENERGY INFORMATION PAGE ENERGY INFORMATION PAGE <br /> ABOVE THE FLOOR WITH A MIN OF 5.7 SQUARE FEET,A MIN WIDTH OF 20"AND A MIN NAILING TO LEDGER <br /> UIII) • <br /> HEIGHT OF 24". PARALLEL OR IIL "TIGHT FIT SOLID PERPENDICULAR NAILING TO SOLID BLOCKING. 11.1 <br /> R-314.3 INTERCONNECTED SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING BLOCKING \ ROOF FRAMING 18MAXIMUM ENCROACHMENT INTO SPACING PER PERIMETER <br /> ROOM, IN THE IMMEDIATE VICINITY OUTSIDE EACH SLEEPING AREA AND ON EACH \ - li 5'SETBACK.THIS WIDTH INCLUDES NAILING OF FLOOR DIAPHRAGM BASEPLATE NAILING • <br /> STORY. 1 .1 TRIM, FINISHES, EAVES AND i PER SW SCHEDULE0BASEPLATE NAILING �\ � kwireat <br /> � OVERHANGS. 1 HOUR MINIMUM FIRE °� <br /> PER SW SCHEDULE ! RESISTIVE CONSTRUCTION. ; ....• 3/4" FLOOR PLYWOOD <br /> SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY RIM JOIST 3/4" FLOOR PLYWOOD \\,m4 <br /> FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A TUB OR <br /> MEN <br /> SHOWER. R314 <br /> 2X LEDGER, BLOCK, L RIM JOIST P� <br /> SHEARWALL PER RAFTER OR TRUSS WITH iW1). <br /> )n %c �� FLOOR JOIST <br /> SCHEDULE FLOOR JOISTIONIZATION SMOKE ALARMS: SHALL NOT BE INSTALLED LESS THAN 20 FT (2)16D TO EACH STUD I / PER PLAN II PER PLAN <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. 4,71til E . <br /> ►� l � 1 P.-7....:::-'0_, <br /> PmInli <br /> • <br /> IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH SHALL NOT BE FLOOR JOIST ' PERIMETER NAILING *man. LL <br /> WALL FRAMING FLOOR TO TOP <br /> 0 <br /> INSTALLED LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED PER SW SCHEDULE BATT INSULATION PER BASEPLATE NAILING FLOOR TO TOP \ <br /> COOKING APPLIANCE. ENERGY INFORMATION PAGE PER SW SCHEDULE ,> PLATE CONNECTIONPLATE CONNECTION <br /> • <br /> / PER SW SCHEDULE PER SW SCHEDULEE i <br /> PHOTO ELECTRIC SMOKE ALARMS:SHALL NOT BE INSTALLED LESS THAN 6 FT TYPICAL PARALLEL OR WALL FRAMING LLI <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. PERPENDICULAR LOWER �8" CANTILEVER INTRUDING INTO TYPICAL UPPER FLOOR <br /> R315.1 CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SLEEPING 0 ROOF TO WALL CONNECTION C3 5 FT PROPERTY LINE SETBACK 0 CANTILEVER UPPER FLOOR 10 JOIST SECTION <br /> AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. <br /> R-308.4 SAFETY GLAZING IS REQUIRED AT ENCLOSURES FOR TUBS AND SHOWERS <br /> AND WHEN PLACED WITHIN 24"ARC OF EITHER VERTICAL EDGE OF DOOR AND 12"MIN REQUIRED 3/4"SUBFLOOR NAILED WITH 8D AT 6" BASEPLATE NAILING <br /> GLAZING IS LESS THAN 60"ABOVE FLOOR. BETWEEN BEAM AND OC AT EDGES AND 12"OC AT FIELD PER SW SCHEDULE NAILING TO SOLID BLOCKING. BASEPLATE NAILING <br /> GROUND. 18"MIN SPACING PER PERIMETER WALL FRAMING PER SW SCHEDULE Lii <br /> M-1503 RANGE HOOD SHALL DISCHARGE TO THE OUTDOORS THROUGH A SINGLE REQUIRED BETWEEN BATT INSULATION \ NAILING OF FLOOR DIAPHRAGM \ \ WALL FRAMING <br /> WALL DUCT THE DUCT SERVING THE HOOD SHALL HAVE A SMOOTH INTERIOR JOISTS AND GROUND. PER ENERGY BATT INSULATION \ I • <br /> SURFACE, SHALL BE AIR TIGHT AND SHALL BE EQUIPPED WITH A BACKDRAFT / 3/4" FLOOR PLYWOOD PER ENERGY 3/4" FLOOR PLYWOOD <br /> DAMPER. SOLID BLOCKING OVER BEAM INFORMATION PAGE x 4"CONCRETE SLAB FLOOR \� <br /> INFORMATION PAGE <br /> �n - 1' <br /> \ \ /� ft <br /> I FLOOR JOIST PRESSURE TREATED FLOOR JOIST <br /> R319.1 BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS. MIN SIZE 4 IN WITH FLOOR JOIST I I r, „„^\ \ J PER PLAN SILL PLATE RIM JOIST �I, PER PLAN <br /> 1/2 IN STROKE AND CONTRASTING BACKGROUND AND VISIBLE FROM STREET. PER PLAN _ V V\ c N <br /> i\ RIM JOIST ,. °'\ PRESSURE TREATED CO W <br /> DESIGN CRITERIA PT POST OR 90LB XPROVIDE A23 AND AC4 = -I = -IIINIEW ' <br /> FELT AT BOTTOM OR APPROVED _ _ 1!11111 II Il Il III -1 SILL PLATE _ ° FLOOR TO TOP W <br /> FLOOR TO TOP <br /> �T(` PLATE CONNECTION <br /> ROOF LIVE LOAD 25-ROOF DEAD LOAD 15 k-‹ POSITIVE CONNECTION BATT INSULATION 1!_111-11 I• PERE SCHEDULE -1111_,_ III 1 '' ' 1111�111111111111111I11111111 IIIIIII�IIII11II1111111 . ` PLATE CONNECTION W <br /> FLOOR LIVE LOAD 40-FLOOR DEAD LOAD 10 UPSTATE ENGINEERING 6 MIL BLACK \ PER ENERGY 11 III- 111-111-111-111-11 , • -111=111 111=111=111 III 111-111 III-1_1 ' I, . PER SW SCHEDULE ® n/ <br /> VAPOR BARRIER -11=11 = LL <br /> PO BOX 952 CONCRETE INFORMATION PAGE =I11=111= =111=III=111=111= 11=111-111=111=111= =111=1TI 111=III <br /> DECK LIVE LOAD 60 DECK DEAD LOAD 10 \ 11-111-11 °% • 111=111=111=1_11=11 =111=111-111=111-111 111=111=111 111-11 <br /> LYNNWOOD,WA 98046 FOOTING 111111=111=11 F 111=11!=111-1I I- •'111=111=111=111=111=1 111=111=111=111- Z <br /> 206-280-4715 PER PLAN III 111=111 111-1 I, ,I ' 111 1111!1 111=11 111-111-111=111 111- l l I 111=1,1 IT I I - �/ N <br /> -III 111 111 1 III 111-111= 111 111 111 <br /> WIND SPEED 85 SEISMIC CAT. D ° _ <br /> � -I I 1-III III - - • III III-III I °- -III III-I I 1=1 III I I 1=1 I I I ° • °,° <br /> III 111111 ° -111 11/1111111 ' 11 III II111' III III <br /> STRUCTURAL REVIEW J IIIEHI 1 111 °, : n _ I� =111 nl 111 111=111 1� n Ll.l <br /> THIS DRAWING HAS BEEN III—III-11� iu—iii—in ui_I_Ii 11/11/111 III— '- 111 III—lii—iii—ii iii iii=ii—iii =III_ _I�!-111 111 SII) III VIII=IIII�II r <br /> REVIEWED FOR STRUCTURAL I\IIHI! III-1 1= !-111=111— U11==111=111-41=111E111=111=1- ��L 111=4110111111=111=111=111E1= = <br /> ,f1=111- 111=111=111E-111=111=111—=11=111=111_=111—L-111=111=111_ -- "' 11j= —III =11b <br /> REQUIREMENTS ONLY PER THE , 111=111-111 11 111-111—III-111111—III-111=111=1111�1I <br /> ATTACHED LETTER/CALCULATIONS <br /> PROVIDED BY THIS OFFICE. CRAWL SPACE BEAM FOUNDATION AT FOUNDATION AT <br /> REVIEWED BY: am B4 CD1CANTILEVER LOWER FLOOR B2 GARAGE SLAB FLOOR B1 FRAMED FLOOR JOIST I J9 \\ SUPPORT SECTION O <br /> DATE: 5/30/19 JOB# 01-1-9 <br /> THE GREATEST RISER HEIGHT WITHIN ANY • <br /> MSTC66 @CENTERLINE CAST-IN-PLACE ANCHOR BOLT TO BE 5/8"X 10"WITH 3 X 3 X MINSTRI UM COMPRESSIVE C OF CONCRETE r <br /> FLIGHT OF STAIRS SHALL NOT EXCEED THE 1/4 PLATE WASHERS AT 48"OC OR PER SW SCHEDULE. NO W U <br /> SMALLEST BY MORE THAN 3/8" OF RIM JST AND <br /> FILL ALL HOLES w/16d LESS THAN 4 1/2"AND NO MORE THAN 12"FROM EACH END. SHALL BE NOT LESS THAN11 <br /> '=� BEARING WALL 7"MIN EMBEDMENT EXCEPT AS REQUIRED BY SW 3000 PSI <br /> MIN HEAD CLEARANCE SCHEDULE. <br /> HANDRAIL 34-38" / TO BE 6'-8" C ' <br /> FRAMING 2x TREATED PLATE _ . <br /> / II <br /> ABOVE STAIR NOSE � MECHANICAL 8"CONCRETE FOUNDATION \�FASTENER HORIZONTAL: 1 #4 BAR WITHIN CO Cl. <br /> \ STAIR TREAD IF STRAP OVERLAP IS REQ'D,(10)-16d ►—� _1 WALL MAX HEIGHT 96"WITH ( ) <br /> DOUBLE STUDS 12"OF TOP OF WALL R403.1.3.1 <br /> PER R 311.5.3 NAILS MIN SHALL GO THROUGH BOTH @EACH STRAP (2)#4 HORIZONTAL MAX UNBALANCED BACKFILL <br /> STRAPS. RELOCATE MSTC ABOVE REINFORCING ROD NOT TO EXCEED 48" 6"MIN <br /> 1X8 RISER - A FLOOR JOISTS EDGE NAIL SHTG CONCRETE SLAB <br /> CENTERLINE IF REQ'D. DATE: <br /> UNO \ _ r= #4 VERTICAL @ 48"ON CENTER PER <br /> °_ 6"WALL MAYBE USED WITH i- I-! I1=1I I SECTION R403.1.3.1 MIN 14" INTO STEM <br /> 2X12 STRINGERS(3) �� � � MAX HEIGHT 54" 111.11111111111111 ° • <br /> • <br /> °" °•• '�° WALL AND STANDARD HOOK PER <br /> ...I, MECHANICAL �= -III;III- $/19/20 1 9 <br /> I CONNECTION '1-in-111u� iiil=il VAPOR BARRIER 111 SECTION R608.5.4.5 <br /> I I I=I I!=1 11=1 7:111-111.= <br /> FII=1 I I-I 11= _ <br /> FLOOR TO STAIRS II=1_11=III (1)#4 REBAR REQUIRED AT E1111:111111:11111:17, <br /> MIN RUN 17" 1/2"GWB UNDER STAIRS PONY WALL CONSTRUCTION: HOEDOWN 4" GRAVEL BOFOTTOM OFG FOOT NG R403.1.3.1 ' <br /> MAX RISE 7 3/4" I PER PLAN 11 - . MIN 17 X 6 CONCRETE <br /> 2x6 MATCH ABOVE @ 16"o/c 16 X 8 CONTINUOUS THICKENEDFOOTING MIN 12"BELOW EHD JOB: <br /> • <br /> — -,� <br /> �� SHEARWALL SPECIFICATIONS _� SLAB UNDER BEARING WALL — =III-III-III_III-III-III=III=11 GRADE <br /> 2X DRAFT STOP BLOCKING "_ II=111, <br /> BETWEEN STUDS FROM SHEARWALL ABOVE ALL FOOTINGS TO BE PLACED <br /> I�°" ALL STEEL TO BE GRADE 60 2345 <br /> 3/4"-1 1/4"NOSING <br /> 2X4 STIFFENER . ON BEARING SOIL <br /> CONCRETE THICKENED . <br /> Al TYPICAL CONCRETE FOUNDATION ( 8 OR 6 INCH ) SHEET: <br /> A4 TYPICAL STAIR SECTION A3 PONY WALL WITH SW / HOEDOWN O SLAB FOOTING <br /> CITY OF EVERETT 9 <br /> REVIEWED FOR PERMIT <br />